Literature DB >> 29975506

A Transferable, Sample-Independent Calibration Procedure for Trapped Ion Mobility Spectrometry (TIMS).

Mengqi Chai, Meggie N Young, Fanny C Liu, Christian Bleiholder.   

Abstract

Ion mobility spectrometry-mass spectrometry (IMS-MS) determines momentum transfer cross sections of ions to elucidate their structures. Recent IMS methods employ electrodynamic fields or nonstationary buffer gases to separate ions. These methods require a calibration procedure to determine ion mobilities from the experimental data. This applies in particular to trapped IMS (TIMS), a novel IMS method with reported high resolving powers. Here, we report the first systematic assessment of the accuracy and the limitations of mobility calibration in TIMS. Our data show that the currently used TIMS calibration approach reproduces drift tube mobilities to approximately 1% (95th percentile). Furthermore, we develop a transferable and sample-independent calibration procedure for TIMS. The central aspects of our approach are (1) a calibration function derived from a solution to the Boltzmann transport equation and (2) calibration constants based on a Taylor expansion of instrument properties (TEIP). The key advantage of our calibration approach over current ones is its transferability: one equation and one set of parameters are sufficient to calibrate ion mobilities for various instrument settings, compound classes, or charge states. Our approach is transferable over time and sufficiently accurate (∼1-2%) for structure-elucidation purposes. While we develop our calibration procedure specifically for TIMS, the approach we take is generic in nature and can be applied to other IMS systems.

Entities:  

Year:  2018        PMID: 29975506     DOI: 10.1021/acs.analchem.8b01326

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  12 in total

1.  Trapped Ion Mobility Spectrometry of Native Macromolecular Assemblies.

Authors:  Kevin Jeanne Dit Fouque; Alyssa Garabedian; Fenfei Leng; Yuk-Ching Tse-Dinh; Mark E Ridgeway; Melvin A Park; Francisco Fernandez-Lima
Journal:  Anal Chem       Date:  2021-01-25       Impact factor: 6.986

Review 2.  Challenges in Identifying the Dark Molecules of Life.

Authors:  María Eugenia Monge; James N Dodds; Erin S Baker; Arthur S Edison; Facundo M Fernández
Journal:  Annu Rev Anal Chem (Palo Alto Calif)       Date:  2019-03-18       Impact factor: 10.745

3.  Validation of Calibration Parameters for Trapped Ion Mobility Spectrometry.

Authors:  Cameron N Naylor; Tobias Reinecke; Mark E Ridgeway; Melvin A Park; Brian H Clowers
Journal:  J Am Soc Mass Spectrom       Date:  2019-08-07       Impact factor: 3.109

4.  Insights and prospects for ion mobility-mass spectrometry in clinical chemistry.

Authors:  David C Koomen; Jody C May; John A McLean
Journal:  Expert Rev Proteomics       Date:  2022-01-17       Impact factor: 3.940

5.  Tandem-trapped ion mobility spectrometry/mass spectrometry coupled with ultraviolet photodissociation.

Authors:  Fanny C Liu; Mark E Ridgeway; J S Raaj Vellore Winfred; Nicolas C Polfer; Jusung Lee; Alina Theisen; Christopher A Wootton; Melvin A Park; Christian Bleiholder
Journal:  Rapid Commun Mass Spectrom       Date:  2021-11-30       Impact factor: 2.586

6.  Ion Mobility Spectrometry: Fundamental Concepts, Instrumentation, Applications, and the Road Ahead.

Authors:  James N Dodds; Erin S Baker
Journal:  J Am Soc Mass Spectrom       Date:  2019-09-06       Impact factor: 3.109

7.  Structural Analysis of the Glycoprotein Complex Avidin by Tandem-Trapped Ion Mobility Spectrometry-Mass Spectrometry (Tandem-TIMS/MS).

Authors:  Fanny C Liu; Tyler C Cropley; Mark E Ridgeway; Melvin A Park; Christian Bleiholder
Journal:  Anal Chem       Date:  2020-02-28       Impact factor: 6.986

8.  Comment on Effective Temperature and Structural Rearrangement in Trapped Ion Mobility Spectrometry.

Authors:  Christian Bleiholder; Fanny C Liu; Mengqi Chai
Journal:  Anal Chem       Date:  2020-11-20       Impact factor: 6.986

9.  Effective discrimination of gas-phase peptide conformers using TIMS-ECD-ToF MS/MS.

Authors:  K Jeanne Dit Fouque; M Wellmann; D Leyva Bombuse; M Santos-Fernandez; Y L Cintron-Diaz; M E Gomez-Hernandez; D Kaplan; V G Voinov; F Fernandez-Lima
Journal:  Anal Methods       Date:  2021-11-11       Impact factor: 2.896

Review 10.  Recommendations for reporting ion mobility Mass Spectrometry measurements.

Authors:  Valérie Gabelica; Alexandre A Shvartsburg; Carlos Afonso; Perdita Barran; Justin L P Benesch; Christian Bleiholder; Michael T Bowers; Aivett Bilbao; Matthew F Bush; J Larry Campbell; Iain D G Campuzano; Tim Causon; Brian H Clowers; Colin S Creaser; Edwin De Pauw; Johann Far; Francisco Fernandez-Lima; John C Fjeldsted; Kevin Giles; Michael Groessl; Christopher J Hogan; Stephan Hann; Hugh I Kim; Ruwan T Kurulugama; Jody C May; John A McLean; Kevin Pagel; Keith Richardson; Mark E Ridgeway; Frédéric Rosu; Frank Sobott; Konstantinos Thalassinos; Stephen J Valentine; Thomas Wyttenbach
Journal:  Mass Spectrom Rev       Date:  2019-02-01       Impact factor: 10.946

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.