Sheathless coupling of microchip electrophoresis to ESI-MS utilising an integrated photo polymerised membrane for electric contacting.

T Scholl1, C Dietze1, M Schmidt1, S Ohla1, D Belder2.   

Abstract

In this article, we present a novel approach for the sheathless coupling of microchip electrophoresis (MCE) with electrospray mass spectrometry (ESI-MS). The key element is an ion-conductive hydrogel membrane, placed between the separation channel and an adjacent microfluidic supporting channel, contacted via platinum electrodes. This solves the persistent challenge in hyphenation of mass spectrometry to chip electrophoresis, to ensure a reliable electrical connection at the end of the electrophoresis channel without sacrificing separation performance and sensitivity. Stable electric contacting is achieved via a Y-shaped supporting channel structure, separated from the main channel by a photo polymerised, ion permeable hydrogel membrane. Thus, the potential gradient required for performing electrophoretic separations can be generated while simultaneously preventing gas formation due to electrolysis. In contrast to conventional make-up or sheathflow approaches, sample dilution is also avoided. Rapid prototyping allowed the study of different chip-based approaches, i.e. sheathless, open sheathflow and electrode support channel designs, for coupling MCE to ESI-MS. The performance was evaluated with fluorescence microscopy and mass spectrometric detection. The obtained results revealed that the detection sensitivity obtained in such Y-channel chips with integrated hydrogel membranes was superior because sample dilution or loss was prevented. Furthermore, band broadening is reduced compared to similar open structures without a membrane.

Entities:  

Keywords:  Chip; Contacting; Electrophoresis; Fluorescence; Hydrogel; Mass spectrometry

Year:  2018        PMID: 29974150     DOI: 10.1007/s00216-018-1226-0

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  2 in total

Review 1.  Challenging Bioanalyses with Capillary Electrophoresis.

Authors:  Courtney J Kristoff; Lloyd Bwanali; Lindsay M Veltri; Gayatri P Gautam; Patrick K Rutto; Ebenezer O Newton; Lisa A Holland
Journal:  Anal Chem       Date:  2019-12-02       Impact factor: 6.986

2.  On-chip mass spectrometric analysis in non-polar solvents by liquid beam infrared matrix-assisted laser dispersion/ionization.

Authors:  Raphael D Urban; Tillmann G Fischer; Ales Charvat; Konstantin Wink; Benjamin Krafft; Stefan Ohla; Kirsten Zeitler; Bernd Abel; Detlev Belder
Journal:  Anal Bioanal Chem       Date:  2021-01-21       Impact factor: 4.142