Abstract
The continuous flow alcoholysis of dialkyl H-phosphonates by aliphatic alcohols in the absence of a catalyst was elaborated using a microwave (MW) reactor equipped with a flow cell. By the precise control of the reaction conditions, the synthesis could be fine-tuned towards dialkyl H-phosphonates with two different and with two identical alkyl groups. In contrast to the "traditional" batch alcoholysis, flow approaches required shorter reaction times, and the products became available at a larger scale.Entities:
Keywords: alcoholysis; continuous flow reactor; dialkyl H-phosphonates; microwave; transesterification
Mesh:
Substances:
Year: 2018 PMID: 29970851 PMCID: PMC6100214 DOI: 10.3390/molecules23071618
Source DB: PubMed Journal: Molecules ISSN: 1420-3049 Impact factor: 4.411
Scheme 1Synthesis of dialkyl H-phosphonates from phosphorus trichloride.
Scheme 2Synthesis of dialkyl H-phosphonates by alcoholysis.
Scheme 3Miscellaneous synthesis of dialkyl H-phosphonates.
Synthetic methods for the preparation of dialkyl H-phosphonates bearing two different alkyl groups.
| Entry | Reaction | Average Yield (%) | Flow Compatible | Ref. |
|---|---|---|---|---|
|
|
| 30–50 | + | [ |
|
|
| 50–70 | − | [ |
|
|
| 50–85 | − | [ |
|
|
| 30–60 | − | [ |
Alcoholysis of dialkyl H-phosphonates in a batch microwave (MW) reactor [33].
| Entry | R1 | R2 | R2OH (equiv) | T (°C) | t (min) | Composition (%) a | ||
|---|---|---|---|---|---|---|---|---|
| A | B | C | ||||||
|
| Me | Et | 25 | 100 | 120 | 22 |
| 22 |
|
| Me | Et | 50 | 175 | 40 | 0 | 4 |
|
|
| Me | 25 | 125 | 60 | 0 |
| 60 | |
|
| Me | 50 | 150 | 60 | 0 | 0 |
| |
|
| Et | Me | 25 | 125 | 120 | 49 |
| 13 |
|
| Et | Me | 50 | 175 | 40 | 0 | 21 |
|
|
| Et | 25 | 125 | 60 | 26 |
| 17 | |
|
| Et | 50 | 175 | 40 | 0 | 6 |
| |
|
| Et | 25 | 125 | 60 | 25 |
| 21 | |
|
| Et | 50 | 175 | 40 | 0 | 2 |
| |
|
| Et | 25 | 125 | 60 | 3 |
| 45 | |
|
| Et | 50 | 175 | 40 | 0 | 8 |
| |
a Analyzed by GC. Bold numbers indicate the target compounds in the reactions.
Figure 1Schematic drawing of the continuous flow system developed.
Figure 2Sketch of the continuous flow cell.
Continuous flow alcoholysis of DMP with BuOH.
| Entry | Mode of Heating | Power (W) | T | Flow Rate | τ | Conversion (%) | Composition (%) c | Yield (%) d | ||
|---|---|---|---|---|---|---|---|---|---|---|
| (mL/min) b | 1 | 2a | 3a | |||||||
|
| MW | 22 | 100 | 1.4 | 5 | 26 | 74 | 25 | 1 | - |
|
| MW | 14 | 100 | 0.45 | 15 | 52 | 48 | 44 | 8 | - |
|
| MW | 10 | 100 | 0.25 | 30 | 65 | 35 |
| 12 | 48 ( |
|
| MW | 8 | 100 | 0.15 | 45 | 76 | 24 | 50 | 26 | - |
|
| MW | 5 | 100 | 0.10 | 60 | 83 | 18 | 47 | 35 | - |
|
| Δ | - | 100 | 0.25 | 30 | 15 | 85 | 15 | 0 | - |
|
| MW | 18 | 125 | 0.25 | 30 | 93 | 7 | 43 | 50 | - |
|
| MW | 38 | 150 | 0.25 | 30 | 100 | 0 | 22 | 78 | - |
|
| MW | 59 | 175 | 0.25 | 30 | 100 | 0 | 9 |
| 88 ( |
|
| Δ | - | 175 | 0.25 | 30 | 98 | 2 | 15 | 83 | - |
a The pressure was 17 bar; b Based on the HPLC pump; c the mixtures from the stationary operation were analyzed by GC; d after column chromatography; e No change on longer residence time (45 min); f No change on higher excess (50 equiv) of BuOH. Bold numbers indicate the target compounds in the reactions.
Figure 3Composition of the reaction mixtures of the MW-assisted alcoholysis of DMP with BuOH at different temperatures at a residence time of 30 min (Table 3 entries 3 and 7–9).
Comparative experiments for the alcoholysis of dimethyl H-phosphonate (DMP) with BuOH in a batch MW reactor.
| Entry | t (min) | Conversion (%) | Composition (%) a | ||
|---|---|---|---|---|---|
| 1 | 2a | 3a | |||
|
| 5 | 24 | 76 | 20 | 4 |
|
| 15 | 46 | 54 | 37 | 9 |
|
| 30 | 59 | 41 | 47 | 12 |
|
| 45 | 67 | 33 | 49 | 18 |
|
| 60 | 73 | 26 | 45 | 29 |
a Based on GC.
Figure 4Reaction/residence time-dependence of the conversion of the alcoholysis of DMP with BuOH at 100 °C.
Figure 5Reaction/residence time-dependence of the product 2a ratio in the alcoholysis of DMP with BuOH at 100 °C.
Continuous flow alcoholysis of DMP with various alcohols.
| Entry | R | Power (W) | T (°C) a | Composition (%) b | Yield (%) c | ||
|---|---|---|---|---|---|---|---|
| 1 | 2 | 3 | |||||
|
| 10 | 100 | 45 |
| 9 | 42 ( | |
|
| 57 | 175 | 0 | 10 |
| 85 ( | |
|
| 10 | 100 | 38 |
| 11 | 46 ( | |
|
| 71 | 175 | 0 | 10 |
| 86 ( | |
|
| 10 | 100 | 32 |
| 13 | 51 ( | |
|
| 55 | 175 | 0 | 8 |
| 88 ( | |
a The pressure was 17 bar; b the mixtures from the stationary operation were analyzed by GC; c after column chromatography. Bold numbers indicate the target compounds in the reactions.
Continuous flow alcoholysis of DEP with alcohols.
| Entry | R | Power (W) | T (°C) a | Composition (%) b | Yield (%) c | ||
|---|---|---|---|---|---|---|---|
| 4 | 5 | 3 | |||||
|
| 10 | 100 | 58 | 34 | 8 | - | |
|
| 17 | 125 | 44 |
| 14 | 38 ( | |
|
| 38 | 150 | 7 | 32 | 61 | - | |
|
| 57 | 175 | 0 | 11 |
| 85 ( | |
|
| 18 | 125 | 51 |
| 8 | 36 ( | |
|
| 54 | 175 | 4 | 22 | 74 | – | |
|
| 83 | 200 | 2 | 14 |
| 78 ( | |
|
| 21 | 125 | 21 |
| 39 | 36 ( | |
|
| 63 | 175 | 3 | 26 | 71 | – | |
|
| 105 | 200 | 0 | 16 |
| 77 ( | |
|
| 10 | 125 | 31 |
| 25 | 40 ( | |
|
| 39 | 175 | 2 | 13 |
| 80 ( | |
a The pressure was 17 bar; b the mixtures from the stationary operation were analyzed by GC; c after column chromatography; d no change upon longer residence time (45 min); e no change upon higher excess (50 equiv) of BuOH. Bold numbers indicate the target compounds in the reactions.
Figure 6Design parameters of the continuous flow system.
31P-NMR and mass data for the dialkyl H-phosphonates prepared.
| Compound | δP (CDCl3) | δP [Ref] | [M + H]+found | [M + H]+requires |
|---|---|---|---|---|
|
| 9.3 (695.0) | 9.3 [ | 153.0684 | 153.0681 |
|
| 9.3 (695.4) | ‒ | 139.0522 | 139.0523 |
|
| 6.7 (695.7) | ‒ | 153.0676 | 153.0681 |
|
| 6.8 (695.2) | ‒ | 167.0833 | 167.0837 |
|
| 7.8 | 7.9 [ | 195.1153 | 195.1150 |
|
| 7.9 | 7.8 [ | 167.0833 | 167.0837 |
|
| 8.1 | 8.0 [ | 195.1145 | 195.1150 |
|
| 7.8 | 8.1 [ | 223.1462 | 223.1463 |
|
| 7.6 (693.0) | 7.6 [ | 167.0840 | 167.0837 |
|
| 8.6 (692.4) | ‒ | 153.0673 | 153.0681 |
|
| 7.8 (692.8) | ‒ | 167.0832 | 167.0837 |
|
| 7.7 (692.1) | 7.7 [ | 181.0992 | 181.0994 |