Literature DB >> 29969420

Ex Vivo and In Vivo Monitoring and Characterization of Thermal Lesions by High-Intensity Focused Ultrasound and Microwave Ablation Using Ultrasonic Nakagami Imaging.

Siyuan Zhang, Shaoqiang Shang, Yuqiang Han, Chunming Gu, Shan Wu, Sihao Liu, Gang Niu, Ayache Bouakaz, Mingxi Wan.   

Abstract

The feasibility of ultrasonic Nakagami imaging to evaluate thermal lesions by high-intensity focused ultrasound and microwave ablation was explored in ex vivo and in vivo liver models. Dynamic changes of the ultrasonic Nakagami parameter in thermal lesions were calculated, and ultrasonic B-mode and Nakagami images were reconstructed simultaneously. The contrast-to-noise ratio (CNR) between thermal lesions and normal tissue was used to estimate the contrast resolution of the monitoring images. After thermal ablation, a bright hyper-echoic region appeared in the ultrasonic B-mode and Nakagami images, identifying the thermal lesion. During thermal ablation, mean values of Nakagami parameter showed an increasing trend from 0.72 to 1.01 for the ex vivo model and 0.54 to 0.72 for the in vivo model. After thermal ablation, mean CNR values of the ultrasonic Nakagami images were 1.29 dB (ex vivo) and 0.80 dB (in vivo), significantly higher ( ) than those for B-mode images. Thermal lesion size, assessed using ultrasonic Nakagami images, shows a good correlation to those obtained from the gross-pathology images (for the ex vivo model: length, = 0.96; width, = 0.90; for the in vivo model: length, = 0.95; width, = 0.85). This preliminary study suggests that ultrasonic Nakagami parameter may have a potential use in evaluating the formation of thermal lesions with better image contrast. Moreover, ultrasonic Nakagami imaging combined with B-mode imaging may be utilized as an alternative modality in developing monitoring systems for image-guided thermal ablation treatments.

Mesh:

Year:  2018        PMID: 29969420     DOI: 10.1109/TMI.2018.2829934

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  2 in total

Review 1.  A review of conventional and newer generation microwave ablation systems for hepatocellular carcinoma.

Authors:  Kento Imajo; Yuji Ogawa; Masato Yoneda; Satoru Saito; Atsushi Nakajima
Journal:  J Med Ultrason (2001)       Date:  2020-01-20       Impact factor: 1.314

2.  High Contrast Ultrasonic Method With Multi-Spatiotemporal Compounding for Monitoring Catheter-Based Ultrasound Thermal Therapy: Development and Ex Vivo Evaluations.

Authors:  Diya Wang; Matthew S Adams; Peter D Jones; Dong Liu; Everette C Burdette; Chris J Diederich
Journal:  IEEE Trans Biomed Eng       Date:  2021-09-20       Impact factor: 4.756

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.