Clinical outcomes in periarticular knee fractures with flexible fixation using far cortical locking screws in locking plate: a prospective study.

B Kidiyoor1, P Kilaru1, K R Rachakonda1, V M Joseph1, G V Subramaniam1, S R Sankineani2, A Nugur1, A V Gurava Reddy1.   

Abstract

PURPOSE: Periarticular fractures around the knee joint are treated traditionally by locking plates which provide excellent stability but suppress callus formation. Far cortical locking (FCL) screws allow axial motion and enhance uniform callus formation. Our study aims to evaluate the outcomes of FCL screws in traditional locking plate in periarticular fractures of the knee.
METHODS: Thirty patients with periarticular fractures of the knee joint were operated with locking plate using FCL screws. All patients were evaluated clinically and radiographically using X-rays at 6, 12, 24 weeks, 1 year and with CT scan at 12-weeks follow-up.
RESULTS: The average time for complete union was 20 weeks in tibial fractures and 24 weeks in femur fractures. Average time to full weight bearing ambulation was 4.8 ± 0.93 weeks. One patient had delayed union in which union was complete after 9 months.
CONCLUSION: This study shows that FCL screws in locking plates allow uniform callus formation and fracture union with minimal complication rates.

Entities:  

Keywords:  Distal femur; Far cortical locking screw; Locking plate; Periarticular knee fractures; Tibial plateau

Mesh:

Year:  2018        PMID: 29968233     DOI: 10.1007/s12306-018-0553-9

Source DB:  PubMed          Journal:  Musculoskelet Surg        ISSN: 2035-5114


  4 in total

1.  Horizontal Rafting Plate for Treatment of the Tibial Plateau Fracture.

Authors:  Zhong-Yu Liu; Jin-Li Zhang; Tao Zhang; Qing Cao; Jun-Chao Zhao; En-Qi Li; Qi-Jie Shen; Bao-Cheng Zhao; Yu-Chen Zheng; Yang Chen
Journal:  Orthop Surg       Date:  2021-05-11       Impact factor: 2.071

2.  Comparative evaluation of minimally invasive 'tibial tuberoplasty' surgical technique versus conventional open surgery for Schatzker II-III tibial plateau fractures: design of a multicentre, randomised, controlled and blinded trial (TUBERIMPACT study).

Authors:  Tanguy Vendeuvre; Olivier Monlezun; Claire Brandet; Pierre Ingrand; Isabelle Durand-Zaleski; Louis-Etienne Gayet; Arnaud Germaneau; Frederic Khiami; Manuel Roulaud; Guillaume Herpe; Philippe Rigoard
Journal:  BMJ Open       Date:  2019-09-03       Impact factor: 2.692

3.  Assessment of the efficacy of the far cortical locking technique in proximal humeral fractures: a comparison with the conventional bi-cortical locking technique.

Authors:  Joong-Bae Seo; Jae-Sung Yoo; Yeon-Jun Kim; Kyu-Beom Kim
Journal:  BMC Musculoskelet Disord       Date:  2020-12-02       Impact factor: 2.362

4.  Optimal design and biomechanical analysis of sandwich composite metal locking screws for far cortical locking constructs.

Authors:  Yuping Deng; Dongliang Zhao; Yang Yang; Hanbin Ouyang; Chujiang Xu; Liang Xiong; Yanbin Li; Wenchang Tan; Gang Huang; Wenhua Huang
Journal:  Front Bioeng Biotechnol       Date:  2022-09-27
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.