Effect of Thickness on Light Transmission and Vickers Hardness of Five Bulk-fill Resin-based Composites Using Polywave and Single-peak Light-emitting Diode Curing Lights.

G A Maghaireh, R B Price, N Abdo, N A Taha, H Alzraikat.   

Abstract

OBJECTIVES: : This study compared light transmission through different thicknesses of bulk-fill resin-based composites (RBCs) using a polywave and a single-peak light-emitting diode light-curing unit (LCU). The effect on the surface hardness was also evaluated.
METHODS: : Five bulk-fill RBCs were tested. Specimens (n=5) of 1-, 2-, 4-, or 6-mm thickness were photopolymerized for 10 seconds from the top using a polywave (Bluephase Style) or single-peak (Elipar S10) LCU, while a spectrophotometer monitored in real time the transmitted irradiance and radiant exposure reaching the bottom of the specimen. After 24 hours of storage in distilled water at 37°C, the Vickers microhardness (VH) was measured at top and bottom. Results were analyzed using multiple-way analysis of variance, Tukey post hoc tests, and multivariate analysis (α=0.05).
RESULTS: : The choice of LCU had no significant effect on the total amount of light transmitted through the five bulk-fill RBCs at each thickness. There was a significant decrease in the amount of light transmitted as the thickness increased for all RBCs tested with both LCUs ( p<0.001). Effect of LCU on VH was minimal (ηp2=0.010). The 1-, 2-, and 4-mm-thick specimens of SDR, X-tra Fill, and Filtek Bulk Restorative achieved a VHbottom/top ratio of approximately 80% when either LCU was used.
CONCLUSIONS: : The total amount of light transmitted through the five bulk-fill RBCs was similar at the different thicknesses using either LCU. The polywave LCU used in this study did not enhance the polymerization of the tested bulk-fill RBCs when compared with the single-peak LCU.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 29953339     DOI: 10.2341/17-163-L

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  3 in total

1.  Heat Development in the Pulp Chamber During Curing Process of Resin-Based Composite Using Multi-Wave LED Light Curing Unit.

Authors:  Bo Wold Nilsen; Mathieu Mouhat; Torbjørn Haukland; Ulf Thore Örtengren; James B Mercer
Journal:  Clin Cosmet Investig Dent       Date:  2020-07-08

2.  Evaluation of microhardness, sorption, solubility, and color stability of bulk fill resins: A comparative study.

Authors:  Luís-Felipe Espíndola-Castro; Márcia-de Almeida Durão; Tacyandra-Victória-Gomes Pereira; Ayanne-Karine-de Barros Cordeiro; Gabriela-Queiroz-de Melo Monteiro
Journal:  J Clin Exp Dent       Date:  2020-11-01

3.  Functional and aesthetic rehabilitation in posterior tooth with bulk-fill resin composite and occlusal matrix.

Authors:  Luciana Fávaro Francisconi-Dos-Rios; Johnny Alexandre Oliveira Tavares; Luanderson Oliveira; Jefferson Chaves Moreira; Flavia Pardo Salata Nahsan
Journal:  Restor Dent Endod       Date:  2020-01-03
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.