Data mining investigation of the association between a limb ballistocardiogram and blood pressure.

Peyman Yousefian1, Sungtae Shin, Azin Mousavi, Chang-Sei Kim, Ramakrishna Mukkamala, Dae-Geun Jang, Byung-Hoon Ko, Jongwook Lee, Ui Kun Kwon, Youn Ho Kim, Jin-Oh Hahn.   

Abstract

OBJECTIVE: To investigate the association between a limb ballistocardiogram (BCG) and blood pressure (BP) based on data mining. APPROACH: During four BP-perturbing interventions, the BCG and reference BP were measured from 23 young, healthy volunteers using a custom-manufactured wristband equipped with a MEMS accelerometer and a commercial continuous BP measurement device. Both timing and amplitude features in the wrist BCG waveform were extracted, and significant features predictive of diastolic (DP) and systolic (SP) BP were selected using stepwise linear regression analysis. The selected features were further compressed using principal component analysis to yield a small set of DP and SP predictors. The association between the predictors thus obtained and BP was investigated by multivariate linear regression analysis. MAIN
RESULTS: The predictors exhibited a meaningful association with BP. When three most significant predictors were used for DP and SP, a correlation coefficient of r  =  0.75  ±  0.03 (DP) and r  =  0.75  ±  0.03 (SP), a root-mean-squared error (RMSE) of 7.4  ±  0.6 mmHg (DP) and 10.3  ±  0.8 mmHg (SP), and a mean absolute error (MAE) of 6.0  ±  0.5 mmHg (DP) and 8.3  ±  0.7 mmHg (SP) were obtained across all interventions (mean  ±  SE). The association was consistent in all the individual interventions (r  ⩾  0.68, RMSE  ⩽  5.7 mmHg, and MAE  ⩽  4.5 mmHg for DP as well as r  ⩾  0.61, RMSE  ⩽  7.9 mmHg, and MAE  ⩽  6.4 mmHg for SP on the average). The minimum number of requisite predictors for robust yet practically realistic BP monitoring appeared to be three. The association between predictors and BP was maintained even under regularized calibration (r  =  0.63  ±  0.05, RMSE  =  9.3  ±  0.8 mmHg, and MAE  =  7.6  ±  0.7 mmHg for DP as well as r  =  0.60  ±  0.05, RMSE  =  14.7  ±  1.4 mmHg, and MAE  =  11.9  ±  1.1 mmHg for SP (mean  ±  SE)). The requisite predictors for DP and SP were distinct from each other. SIGNIFICANCE: The results of this study may provide a viable basis for ultra-convenient BP monitoring based on a limb BCG alone.

Entities:  

Mesh:

Year:  2018        PMID: 29952758     DOI: 10.1088/1361-6579/aacfe1

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  3 in total

1.  The Potential of Wearable Limb Ballistocardiogram in Blood Pressure Monitoring via Pulse Transit Time.

Authors:  Peyman Yousefian; Sungtae Shin; Azin Mousavi; Chang-Sei Kim; Ramakrishna Mukkamala; Dae-Geun Jang; Byung-Hoon Ko; Jongwook Lee; Ui Kun Kwon; Youn Ho Kim; Jin-Oh Hahn
Journal:  Sci Rep       Date:  2019-07-23       Impact factor: 4.379

2.  Physiological Association between Limb Ballistocardiogram and Arterial Blood Pressure Waveforms: A Mathematical Model-Based Analysis.

Authors:  Peyman Yousefian; Sungtae Shin; Azin Sadat Mousavi; Chang-Sei Kim; Barry Finegan; M Sean McMurtry; Ramakrishna Mukkamala; Dae-Geun Jang; Uikun Kwon; Youn Ho Kim; Jin-Oh Hahn
Journal:  Sci Rep       Date:  2019-03-26       Impact factor: 4.379

Review 3.  Current Status and Prospects of Health-Related Sensing Technology in Wearable Devices.

Authors:  Jaegeol Cho
Journal:  J Healthc Eng       Date:  2019-06-16       Impact factor: 2.682

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.