Literature DB >> 29952033

Profilometric changes of peri-implant tissues over 5 years: A randomized controlled trial comparing a one- and two-piece implant system.

Vitor Marques Sapata1,2, Ignacio Sanz-Martín1, Christoph H F Hämmerle1, João B Cesar Neto2, Ronald E Jung1, Daniel S Thoma1.   

Abstract

OBJECTIVES: To assess the profilometric changes of the buccal soft tissues between baseline and 5 years of loading using a one- and two-piece dental implant system.
MATERIALS AND METHODS: Sixty patients randomly received dental implants of either a two-piece type (BRA) or a one-piece type (STM). Casts were obtained at baseline (after crown insertion), at the 1-year and at the 5-year follow-up. Stereolithography files were obtained from the casts for digital superimposition. One implant and the contralateral natural tooth were selected for the analysis. Thirty-three patients (BRA = 16; STM = 17) were included. Measurements included changes for crown height (CH) and estimated soft tissue thickness, as well as the profilometric change at the implant and the tooth site. Nonparametric methods were applied for the statistical analyses and medians and quartiles presented.
RESULTS: The BRA group lost -0.39 mm and the STM group lost -0.40 mm of volume between baseline and the 5-year follow-up at the implant site (p > 0.05). The tooth site lost -0.18 mm (BRA) and -0.12 mm (STM) (p > 0.05). Volume differences between implants and teeth amounted to -0.05 mm (baseline to 1 year) and -0.25 mm (baseline to 5 years) for BRA, while for STM, the values were 0.03 mm (baseline to 1 year) and -0.16 mm (baseline to 5 years). The changes for implant CH at 1 and 5 years of follow-up amounted 0.10 and 0.09 mm (BRA) and to 0.03 and 0.22 mm (STM). The changes in tissue thickness at 1 and 5 years in the BRA group amounted to -0.28 and -0.66 mm at 1 mm, -0.21 and -0.46 mm at 3 mm, and -0.32 and -0.45 mm at 5 mm, respectively. The changes in the STM group amounted to -0.15 and -0.54 mm at 1 mm, -0.24 and -0.48 mm at 3 mm, and -0.32 and -0.57 mm at 5 mm, respectively. No significantly different medians were observed.
CONCLUSIONS: Minimal profilometric and linear changes occurred at implant sites between baseline and 5 years, between implant and tooth sites and between the two implant systems.
© 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  crown; dental implants; denture; fixed; humans; partial; profilometric analysis; soft tissue

Mesh:

Substances:

Year:  2018        PMID: 29952033     DOI: 10.1111/clr.13308

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  4 in total

1.  Primary bone augmentation leads to equally stable marginal tissue conditions comparing the use of xenograft blocks infused with BMP-2 and autogenous bone blocks: A 3D analysis after 3 years.

Authors:  Stefan P Bienz; Michael Payer; Jenni Hjerppe; Jürg Hüsler; Norbert Jakse; Patrick R Schmidlin; Christoph H F Hämmerle; Ronald E Jung; Daniel S Thoma
Journal:  Clin Oral Implants Res       Date:  2021-09-28       Impact factor: 5.021

2.  Effect of osseodensification on the increase in ridge thickness and the prevention of buccal peri-implant defects: an in vitro randomized split mouth pilot study.

Authors:  Fausto Frizzera; Rubens Spin-Neto; Victor Padilha; Nicolas Nicchio; Bruna Ghiraldini; Fábio Bezerra; Elcio Marcantonio
Journal:  BMC Oral Health       Date:  2022-06-13       Impact factor: 3.747

3.  Contour changes of peri-implant tissues are minimal and similar for a one- and a two-piece implant system over 12 years.

Authors:  Miha Pirc; Oliver Harbeck; Vitor M Sapata; Jürg Hüsler; Ronald E Jung; Christoph H F Hämmerle; Daniel S Thoma
Journal:  Clin Oral Investig       Date:  2020-10-15       Impact factor: 3.573

4.  Baseline selection for evaluation of peri-implant soft tissue changes: a clinical trial.

Authors:  Chaoling Zheng; Shimin Wang; Hongqiang Ye; Yunsong Liu; Wenjie Hu; Yongsheng Zhou
Journal:  Ann Transl Med       Date:  2021-10
  4 in total