Improved biodegradability of hardly-decomposable wastewaters from petrochemical industry through photo-Fenton method and determination of optimum operational conditions by response surface methodology.

Mahmood Derakhshan1, Mojtaba Fazeli1.   

Abstract

BACKGROUND: Petrochemical wastewaters are highly polluting due to having various destructive materials such as aromatic hydrocarbons and heavy metal ions. Therefore, they need to be treated before disposal to the environment. However, due to low biodegradability, applying common treatment methods such as activated sludge is not feasible for these wastewaters.
METHODS: Photo-Fenton is an advanced oxidation process which was applied to promote the biodegradability of hardly-decomposable petrochemical wastewaters. The wastewater samples were provided by Maroon and Karoon petrochemical plants, located in Mahshahr, Iran. To design the experiments and analyze the experimental results, response surface method with four variables (input COD and TDS concentrations and injected a dosage of H2O2 and Fe2+) and four fixed parameters (temperature, pH, retention time, and UV power) were used.
RESULTS: The ranges of input COD, H2O2, Fe2+ and TDS were 1000 to 2500 mg L- 1, 1000 to 4000 mg L- 1, 500 to 3000 mg L- 1, and 4500 to 11,500 mg L- 1, respectively. Average input BOD5/COD ratio was 0.09. These ranges and values were determined according to the quality of the raw wastewater and experimental design. Output BOD5/COD ratio was varying between 0.3 and 0.6, which declined with an increase of input COD. The results showed that the biodegradability of the industrial wastewater was promoted upon application of higher H2O2 and Fe2+ concentrations. Meanwhile, TDS concentration had no significant effect on biodegradability of this wastewater. The following optimum conditions were resulted by evaluating the maximum efficiency of the reactor in enhancing the biodegradability of the wastewater: 1000 mg L- 1 input COD, 2668 mg L- 1 H2O2, 1655 mg L- 1 Fe2+, 8000 mg L- 1 TDS, 0.6 output BOD5/COD, 852 mg L- 1 output BOD5 and 939 mg L- 1 output COD.
CONCLUSION: Photo-Fenton method is highly efficient for increasing the biodegradability of petrochemical wastewaters before applying biological wastewater treatment.

Entities:  

Keywords:  Biodegradation; Hardly-decomposable; Petrochemical wastewater; Photo-Fenton

Year:  2018        PMID: 29951111      PMCID: PMC6011265          DOI: 10.1186/s13036-018-0104-9

Source DB:  PubMed          Journal:  J Biol Eng        ISSN: 1754-1611            Impact factor:   4.355


Background

Due to the existence of hazardous pollutants such as aromatic hydrocarbons in petrochemical wastewaters, direct discharge of them to the environment can contaminate the resources and threaten the health of species that live in their vicinity [1]. Hence, discharging petrochemical wastewaters with hazardous pollutants such as petrochemicals and hydrocarbons should follow specific rules and standards [2]. In this respect, petrochemical complexes are under pressure by environment protection campaigns and organizations to reduce their pollutants emission, reuse water, and decrease power consumption to decline carbon effects [3]. In this regard, many studies have attempted to develop new ecofriendly treatment methods with maximum efficiency of pollutant removal, separation, and disposal. Using microalgal systems for nutrient removal [4, 5], aerobic granular sludge [6], using photocatalytic reactors [7] and applying anoxic/oxic process [8, 9] are the newest efforts which are carried out in order to treat petrochemical wastewaters efficiently. As it is obvious, due to the level of organic load and the variety of the contaminants in the wastewater streams in petrochemical industry, biological treatment techniques seem to be inevitable [10]. However, due to existence of different non-biodegradable compounds (mainly hydrocarbons) in petrochemical wastewaters, common biological treatment methods (e.g. activated sludge) are not practically feasible for being applied as the only method of treatment and an efficient pretreatment method is usually necessary to improve the biodegradability of wastewater [11]. Therefore, accelerating techniques which significantly improves wastewater biodegradability are usually employed to solve the problem of wastewater treatment in petrochemical complexes [12]. Advanced oxidation processes (AOPs) can be considered as an effective treatment method to deal with hardly-biodegradable pollutants in wastewaters from the petrochemical industry [13]. Such processes have recently received much attention because of their capabilities of pollutant removal and converting hardly-decomposable materials to biodegradable materials [14]. These methods are based on producing radicals that are highly reactive, non-selective and with high oxidation potency [15]. In general, these methods use free radicals as strong oxidants to break long chain and hardly-decomposable organic molecules to smaller ones, which often offer improved biodegradability and can be used to generate carbon dioxide upon complete degradation [16]. In AOPs, oxidizing agents such as ultrasound, UV, O3, TiO2, and H2O2 are utilized solely or in combination with each other [17]. These methods are often combined with or complement to each other and are used prior to or after other major treatment processes [18]. It has to be noted that when using chemical oxidants, a complete oxidation of the pollutants is not concerned due to the related high costs. Hence, partial oxidation is an effective alternative to enhance biological treatment of specific compounds [19]. There are numerous oxidation methods for decomposition of hardly-biodegradable pollutants in complex wastewater such as petrochemical wastewaters [20]. Photo-Fenton is an effective method which is noticeably efficient for chemical oxidation of hardy-decomposable compounds in wastewater [21, 22]. Classical Fenton reaction is a combination of hydrogen peroxide (H2O2) and Ferro ions (Fe2+) in an acidic medium that results in cleavage of H2O2 into hydroxyl ion and hydroxyl radical and oxidation of Fe2+ to Fe3+ [23, 24]. The reaction takes place at room temperature without input energy [25]. Also, this reaction requires a relatively short time compared to other AOPs [26]. Besides, the needed reactants are readily accessible, can be conveniently stored, and are safe for maintenance [27]. Fenton reaction processes are prompted upon light irradiation and changed to a process known as photo-Fenton [28, 29]. In the presence of UV light, a greater number of OH radicals are generated from both direct photolysis of H2O2 and UV radiative reaction with iron, in aqueous solutions [30] (Eq. 1–3). Therefore, in photo-Fenton process, more OH radicals can be produced and efficiency enhances consequently [31]. This method is based on OH radical generation, which acts as a very strong oxidant in the destruction of compounds that cannot be oxidized with common oxidants such as O2 and O3 [32]. These radicals react with the compounds in solution and initiate a set of oxidation reactions until the compounds reach to the desired decomposition degree or convert to inorganic compounds, completely [33]. The radical has a high oxidation tendency toward most materials, without resistance to any material or a specific group. Furthermore, OH radicals have gained attraction because of their oxidation power, reasonable operational cost, water solubility, and avoiding production of toxic side products. Convenience, simplicity, and efficiency of Fenton process at constant removal rate have been proved elsewhere [34]. Different Fenton-based oxidation processes in petrochemical wastewater treatment have drawn more attention to themselves during last years. Davarnejad et al. (2014) had applied electro-Fenton method using aluminum and iron electrodes in order to treat petrochemical wastewater and had achieved 67 and 54% of COD removal for iron and aluminum respectively [35]. In another study, Wang et al. (2015) had applied Fenton method in order to increase the biodegradability of petrochemical wastewater and had reduced the number of the polluting compounds in the wastewater from 117 to 27 most of which were biodegradable components [36]. Scaratti et al. (2017) applied heterogeneous photo-Fenton process for synthetic petrochemical wastewater using residue-based iron oxide nanocatalysts and graphene oxide in order to compare the influences of these two nanostructures on TOC and COD removal [37]. In this research, it is tried to increase the biodegradability of petrochemical wastewater using photo-Fenton process. The raw wastewaters from petrochemical plants of Maroon and Kroon in Mahshar petrochemical and economic zone, Iran, were used. Since BOD5/COD ratios of these wastewaters are low, they are categorized as hardly-biodegradable wastewaters and common biological treatment methods are not feasible for their treatment. The objective of this research is to enhance the biodegradability of petrochemical wastewaters through enhancing BOD5/COD ratio by photo-Fenton method. Applying photo-Fenton method in order to increase the biodegradability as a pre-treatment method for actual petrochemical wastewater is the main objective of this research.

Methods

Experimental setup

In this study, a rectangular cube glassy reactor with 80 cm length, 20 cm width and 20 cm height was used (Fig. 1).
Fig. 1

Schematic illustration of the photo-Fenton reactor

Schematic illustration of the photo-Fenton reactor A stirrer was placed on the top of the reactor for a complete mixing of the wastewater with chemicals. Moreover, UVC lamps with 60 cm length and 20 W powers (Philips, Netherlands) were installed in the center of the reactor. Inlets of hydrogen peroxide and Fe2+ are shown in Fig. 1. The experiments were considered to be in a batch state with 1 h retention time. Fluid level height was 5 cm and the distance between the UV lamp and the fluid surface was 15 cm. According to the height and length of the fluid (5 and 60 cm, respectively), the volume of the reactor was considered to be 6000 cm3. Based on literature review and field studies, the retention time of 1 h, the temperature of 25 ± 2 °C, and pH = 3 were concerned as fixed parameters.

Chemicals and the specification tests

The chemicals used in this study included hydrogen peroxide (Merck, 30% w/w and MW = 34 g mol− 1), hydrated iron sulfate (FeSO4.7H2O), methanol (CH3OH), sodium hydroxide (NaOH), and sulfuric acid (H2SO4). COD and BOD5 were measured at the reactor inlets and outlets. Also, TDS, H2O2, Fe2+, pH, and temperature were measured based on standard methods [38].

Wastewater composition

Specification of the utilized raw wastewater are listed in Table 1. This wastewater was sampled from a mixture of output wastewaters from Maroon and Karoon petrochemical plants with 2 to 1 ratio. Sampling was performed in spring of 2016. To explore parameter properties in other seasons, when lower pollution level is usually expected, experimental trials of treatment system were used. The most remarkable feature of the used wastewater was a considerable amount of hardly-decomposable materials and a high TDS level.
Table 1

Properties of the natural wastewater used in the experiments

ParameterIndustrial wastewaterSanitary wastewaterMix wastewater for experimental
Karoon petrochemicalMaroon petrochemicalKaroon petrochemical
COD (mg L−1)3980742812498
BOD5 (mg L−1)3457064226
TDS (mg L−1)705024,350140211,186
pH56.575.7
BOD5/COD0.090.090.80.09
Mix ratio210.5
Properties of the natural wastewater used in the experiments As shown in Table 1, the sampled wastewaters were employed with the outlined ratios to achieve qualitative characteristics required for mixture experiments. According to Eq.4, different parameters with experimental responses were compared to acquire mixed raw wastewater.where Pim is the parameter regarding Maroon petrochemical industry wastewater, Pik is the intended parameter corresponding to Karoon petrochemical industry wastewater, Psk is the parameter related to Karoon sanitary petrochemical wastewater, and Pm is the parameter of interest associated with the mixed wastewater. Based on the documents provided by the laboratory of the purgation unit for the other seasons of the year and also Table 1, the employed ranges of COD and TDS were selected to be 1000 to 2500 mg L− 1 and 4500 to 11,500 mg L− 1, respectively.

Experiments conditions and procedure

Experiments were conducted at common lab temperature of 25 ± 2 °C. The pH of all the samples which are entering the reactor were adjusted on 3 using 0.1 M NaOH and 0.1 M H2SO4 [39]. Then, a specific amount of hydrated iron sulfate was added to the reactor. The sample was then mixed with the chemicals and homogenized with the electrical stirrer. The materials were dissolved in the wastewater under UV radiation for 30 min. Photo-Fenton experiment was initiated by gradual addition of hydrogen peroxide (H2O2) [29]. To prevent excess reactions in the sample, 0.1 mL methanol was added to the reactor, at the end of the experiment [40]. Eventually, COD and BOD5 of the outlets were measured by HACH DR/2800 and HACH BOD (HACH, US) instruments, respectively. The procedure was repeated for all trials.

Experimental design and statistical analysis

Response surface method (RSM) has been frequently used to perform statistical analysis and define optimum conditions. The advantages of this method are a reduced number of necessary experiments for result analysis and decreased experimental attempts [41]. In this study, central composite design (CCD) approach was adopted to carry out multi-variable modeling and analysis [42]. The experiment design in this study was through CCD method and by relying on four variable parameters of inlet COD concentration, H2O2 concentration, Fe2+ injected dosage and TDS concentration. Also, Design Expert® 10.01 software was used to devise the experiments, carry out statistical analysis, model and determine optimum conditions. The variables were analyzed at 5 levels (Table 2). The suggested number of experiments was randomly obtained to be 54 trials by considering 6 central repetitions and 2 repetitions in other points. Interactions between the variables and variance analysis of the data (ANOVA) were performed through RSM.
Table 2

The levels used in the parameters used in the test

Parameters-alphaLowCenterHigh+alpha
COD initial10001375175021252500
H2O210001750250032504000
Fe2+5001125175023753000
TDS450062508000975011,500
(BOD/COD)IN0.09
pH3
The levels used in the parameters used in the test Quality of the model and the predicted values can be determined by an R2 coefficient. The variables used in this part are recorded by Eq.5.where Xi is the encoded value of the i-th independent parameter, xi the desired independent parameter, xcp is the value of the independent parameter in the central point, and ∆xi is the value of the parameter change in each step. In the RSM method, the general form of the quadratic fitted equation is in accordance with Eq.6 [43].where Y is the response variable and BOD5/COD ratio in the reactor outlet, β is a constant, β is linear coefficient, β refers to the second order effect of the model, β corresponds to the coefficient of mutual interaction and ε is the statistical error.

Results and discussion

Development and regression equations of the model

The basis of the experimental procedure is the varying values of the independent variable, which was defined according to experimental results and literature review. Experimental design and the measured response are reported in Table 3. As the results illustrate, the empirical relationship between the independent variables and the response was obtained to be Eq.7 using Design expert software, in the framework of CCD method.
Table 3

Experiment design according to RSM method and the measured response

Test numberInput variable parameters (mg L−1)ResponseTest numberInput variable parameters (mg L− 1)Response
CODH2O2Fe2+TDSBOD/CODCODH2O2Fe2+TDSBOD/COD
117501000175080000.2997562817504000175080000.451106
213751750112597500.3856592925002500175080000.356573
321253250112597500.3742843017502500175080000.474479
417502500175011,5000.4211663117502500175080000.396539
513751750112597500.389323213753250112562500.503843
613753250237562500.5814913313753250112562500.501281
717504000175080000.449113413751750112562500.388727
817502500175045000.4241553521253250112562500.374841
917502500175080000.374373621251750237562500.336815
1013753250237597500.5813573713751750237597500.444746
1110002500175080000.598673821253250237562500.428827
1221251750112597500.3004573921253250112562500.374444
1317502500175080000.4601014013751750237597500.444746
`1413753250237597500.5813574121253250237597500.426278
1513751750237562500.4445454213751750237562500.443841
1621251750112562500.3013074317502500175011,5000.422882
171750250050080000.3191154421251750237597500.337247
1810002500175080000.5997774525002500175080000.356953
1917502500300080000.4411974617502500300080000.442775
2013753250237562500.5818334721251750237597500.337247
2121253250237562500.4267864821251750112597500.30085
2221253250237597500.4263574921251750237562500.337467
2321251750112562500.30085501750250050080000.319653
2413753250112597500.4703565121253250112597500.375318
2517502500175080000.4224955213751750112562500.387379
2617502500175080000.4227995317501000175080000.300979
2717502500175045000.4227995413753250112597500.501288
Experiment design according to RSM method and the measured response Regression analysis was performed on the appropriate performance of the response. In the developed second order equation, A, B, and C stand for COD, H2O2, and Fe2+, respectively. Eq.7 describes how BOD5/COD ratio is affected by each individual input variable or by mutual interaction of the variables. BOD5/COD ratio demonstrates linear and second order variations with respect to COD, H2O2, and Fe2+, suggesting that the input independent parameters interact with each other [44]. As shown in Fig. 2, the photo-Fenton method has been very successful in the promoting the biodegradability of petrochemical wastewater. The rate of increase in all tested samples was more than 100%, which in the most rate increased as 506%. The BOD5/COD ratio also increased from 232 to 574%.
Fig. 2

The Photo-Fenton method results in increase BOD5 and (BOD5/COD) ratio

The Photo-Fenton method results in increase BOD5 and (BOD5/COD) ratio

Analysis of variance of the data (ANOVA)

ANOVA results (Table 4) show the success of the model and influence of the input factors on each other and the employed response.
Table 4

Analysis of variance (ANOVA) for BOD5/COD

SourceSUM of SquareDegree of FreedomMean SquareF ValueP- Value Prob > F
Model0.3470.049151.26<0.0001significant
A-COD0.1710.17520.54<0.0001
B-H2O20.1010.10319.78<0.0001
C-Fe2+0.04210.042130.14<0.0001
BC1.087E-00311.087E-0033.360.0732
A29.264E-00319.264E-00328.65<0.0001
B26.679E-00316.679E-00320.66<0.0001
C25.226E-00315.226E-00316.160.0002
Residual0.015463.233E-004
Lack of Fit7.308E-003174.299E-0041.650.1149not significant
Pure Error7.565E-003292.608E-004
Cor Total0.3653
R2 = 95.84%
\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$ {R}_{adj}^2=95.20\% $$\end{document}Radj2=95.20%
Analysis of variance (ANOVA) for BOD5/COD The accuracy of the results and their consistency with the model was investigated through F values of the model and Lack of Fit. A model is accurate when its P and F values are significant while its Lack of Fit is insignificant [45]. F value of the model is 151.26 which is significant. There is 0.01% probability of F value error. Prob > F values below 0.0500 show that the model parameters are statistically significant. In this study, the important A, B, C, A2, B2, and C2 parameters are reported. F value for Lack of Fit is reported to be 1.65 that is negligible compared to the net error. There is an 11.49% possibility that a part of F value in Lack of Fit result from the error. The insignificance of Lack of Fit is a good sign and declares the validity of the model. It means that the model relationships are statistically significant and can predict satisfactory responses. Model consistency was evaluated by determining R2 coefficient. In this study, R2 was obtained to be 0.9584 for BOD5/COD ratio. As R2 approximates unity, the model is stronger and the predicted responses are more reliable. The R2adj value was calculated to be 0.9520 that is a high value for biological decomposition and indicates significance and appropriateness of the model. R2pred was 0.9454 that differs from the R2adj value as much as 0.2. This difference is logically acceptable. The low value of model’s variance coefficient (C.V%), i.e. 4.3, demonstrates precision and proper validity of the experiments [46, 47].

Interactive impacts between the variables

Influence of effective variable parameters on photo-Fenton process (i.e., COD, H2O2, Fe2+, and TDS) on degradation extent of hardly-decomposable organic compounds to molecules with high degradability is explained as follows. Fig. 3 presents interaction impacts of the selected parameters on degradability as a 3D graph.
Fig. 3

Effect of the variable parameters on degradability of wastewater in the outlet of photo-Fenton process. a Effect of input COD and H2O2 on degradability. b Effect of input COD and Fe2+ on degradability. c Effect of input COD and TDS on degradability. d Effect of Fe2+ and H2O2 on degradability

Effect of the variable parameters on degradability of wastewater in the outlet of photo-Fenton process. a Effect of input COD and H2O2 on degradability. b Effect of input COD and Fe2+ on degradability. c Effect of input COD and TDS on degradability. d Effect of Fe2+ and H2O2 on degradability Based on Fig. 3, input COD, H2O2, and Fe2+ parameters pose a noticeable impact on degradability but TDS does not show an effective role in biodegradation of wastewater contents. According to the results, the highest influence is due to input COD, Fe2+, and H2O2, respectively.

Evaluation of the effect of each independent variable on degradability

The effect of each parameter on output BOD5/COD is depicted in Fig. 4. The experiments on each parameter were performed at 5 different levels. As shown in Fig. 4a, wastewater degradability has decreased with input COD increase. This phenomenon is a consequence of the increased amount of materials that can be hardly decomposed in the wastewater inlet with an elevated amount of input COD. As less hardly-decomposable materials are in the wastewater, the OH radicals generated during photo-Fenton process decompose them more feasibly and widely. Accordingly, at the defined time, the organic molecules will be converted into biodegradable molecules more noticeably. The reported BOD5/COD ratio of this section varied from 0.36 to 0.60.
Fig. 4

Effect of each independent parameter on output BOD5/COD. a COD. b H202. c Fe2+. d TDS

Effect of each independent parameter on output BOD5/COD. a COD. b H202. c Fe2+. d TDS As can be seen from Fig. 4b, output BOD5/COD ratio increases with H2O2 concentration up to 3250 mg L− 1. This trend is an outcome of a promoted OH radical generation with accessibility to more H2O2 molecules. As can be seen from the figure, a degradability of 0.30 to 0.45 was achieved. According to Fig. 4c, higher concentrations of Fe2+ give an ascending trend of degradability due to a higher rate of OH radical production. The BOD5/COD ratio was reported to be within the range of 0.32 to 0.44. No BOD5/COD increasing or decreasing effect was observed for TDS parameter on photo-Fenton process. In all conducted evaluations, the BOD5/COD ratio of the wastewater was reported to be 0.3 to 0.6 in photo-Fenton process. This finding demonstrates a high efficiency of photo-Fenton process in the provision of biodegradability for wastewaters with high contents of hardly-decomposable organic materials in saline mediums.

Optimum conditions

According to the obtained results, selection of the optimum values of each parameter is crucial for the efficient performance of the reactor in purgation systems. Therefore, the outlined model was used to identify the optimum status in order to reach high degradability of the wastewater, from both operational and economic perspectives. According to Table 5, the values of H2O2, and Fe2+ consumption, which are economically important, were adjusted to their minimum values. Moreover, input COD and TDS, which varied with respect to the input wastewater, were kept in a certain range and the BOD5/COD ratio was considered to be the highest possible value in selecting the optimum points. A total of 24 optimum points were achieved by the model, among which the state provided in Table 6 was the best point.
Table 5

Selection of different economic and operational statuses for an optimum point

ParameterGOALImportance
Inlet CODin range***
H2O2minimize***
Fe2+minimize***
TDSin range***
BOD5 (OUT)in range***
COD (OUT)in range***
BOD5/COD (ratio)maximize*****
Table 6

The most appropriate observed optimum condition for promotion of biodegradability

Inlet COD (mg L−1)H2O2 (mg L−1)Fe2+ (mg L−1)TDS (mg L−1)Outlet COD (mg L−1)Outlet BOD5 (mg L−1)BOD5/COD (ratio)
1000.042668.091655.445287.449395820.6
Selection of different economic and operational statuses for an optimum point The most appropriate observed optimum condition for promotion of biodegradability As can be observed in Table 6, wastewater degradability is quite successful under optimum conditions. By maintaining the conditions of the wastewater entering treatment unit at the suggested values, the photo-Fenton process will provide a biological wastewater that can be treated by biological methods efficiently.

Conclusion

Using a successful modeling by Design Expert 10.0.1, it was found that three parameters of input COD, H2O2, and Fe2+ have great impacts on conversion of hardly-decomposable materials into biodegradable molecules that can be purged by biological methods. TDS that is an indication of medium salinity did not pose any significant effect on photo-Fenton process. In all stages of the experiments by photo-Fenton method, BOD5/COD ratio varied from 0.3 to 0.6. These values demonstrate the suitability of photo-Fenton process for decomposition of petrochemical industry wastewater into biodegradable materials in any experimental condition. The BOD5/COD ratio was reduced with input COD increase but enhanced by increasing injection dosages of H2O2 and Fe2+. The maximum BOD5/COD ratio was reported to be 0.6 that the high potential of photo-Fenton process in the decomposition of the wastewater materials into biodegradable compounds.
  19 in total

1.  Impact of salinity and pH on the UVC/H2O2 treatment of reverse osmosis concentrate produced from municipal wastewater reclamation.

Authors:  Kai Liu; Felicity A Roddick; Linhua Fan
Journal:  Water Res       Date:  2012-04-02       Impact factor: 11.236

2.  Biodegradation potential and bacterial diversity of a petrochemical wastewater treatment plant in Iran.

Authors:  S Shokrollahzadeh; F Azizmohseni; F Golmohammad; H Shokouhi; F Khademhaghighat
Journal:  Bioresour Technol       Date:  2008-02-05       Impact factor: 9.642

3.  Box-Behnken design: an alternative for the optimization of analytical methods.

Authors:  S L C Ferreira; R E Bruns; H S Ferreira; G D Matos; J M David; G C Brandão; E G P da Silva; L A Portugal; P S dos Reis; A S Souza; W N L dos Santos
Journal:  Anal Chim Acta       Date:  2007-07-23       Impact factor: 6.558

4.  Fenton treatment of complex industrial wastewater: optimization of process conditions by surface response method.

Authors:  Barbara Bianco; Ida De Michelis; Francesco Vegliò
Journal:  J Hazard Mater       Date:  2010-12-21       Impact factor: 10.588

5.  Advanced treatment of petrochemical wastewater by combined ozonation and biological aerated filter.

Authors:  Pengyuan Ding; Libing Chu; Jianlong Wang
Journal:  Environ Sci Pollut Res Int       Date:  2018-01-24       Impact factor: 4.223

6.  The role of hydroxyl radicals for the decomposition of p-hydroxy phenylacetic acid in aqueous solutions.

Authors:  F J Benitez; J L Acero; F J Real; F J Rubio; A I Leal
Journal:  Water Res       Date:  2001-04       Impact factor: 11.236

7.  Comparative study of Cd(II) and Cr(VI) biosorption on Staphylococcus xylosus and Pseudomonas sp. in single and binary mixtures.

Authors:  M Ziagova; G Dimitriadis; D Aslanidou; X Papaioannou; E Litopoulou Tzannetaki; M Liakopoulou-Kyriakides
Journal:  Bioresour Technol       Date:  2006-11-13       Impact factor: 9.642

8.  Fenton and photo-Fenton oxidation of textile effluents.

Authors:  Montserrat Pérez; Francesc Torrades; Xavier Domènech; José Peral
Journal:  Water Res       Date:  2002-06       Impact factor: 11.236

9.  Removal of some polycyclic aromatic hydrocarbons from petrochemical wastewater using low-cost adsorbents of natural origin.

Authors:  Rudy Crisafully; Maria Aparecida L Milhome; Rivelino M Cavalcante; Edilberto R Silveira; Denis De Keukeleire; Ronaldo F Nascimento
Journal:  Bioresour Technol       Date:  2007-10-25       Impact factor: 9.642

10.  Kinetics and mechanism of carbamazepine degradation by a modified Fenton-like reaction with ferric-nitrilotriacetate complexes.

Authors:  Sheng-Peng Sun; Xia Zeng; Ann T Lemley
Journal:  J Hazard Mater       Date:  2013-03-01       Impact factor: 10.588

View more
  1 in total

1.  CuO and CeO2 assisted Fe2O3/attapulgite catalyst for heterogeneous Fenton-like oxidation of methylene blue.

Authors:  Ting Zhang; Lingyu Dong; Jianhua Du; Chunyuan Qian; Yi Wang
Journal:  RSC Adv       Date:  2020-06-19       Impact factor: 4.036

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.