Anh Q Vo1, Herman He2, Jiaxiang Zhang1, Scott Martin2, Rui Chen2, Michael A Repka3,4.
Abstract
Continuous manufacturing, a gaining interest paradigm in the pharmaceutical industry, requires in-process monitoring of critical process parameters to ensure product consistency. This study demonstrated the application of Fourier transform near-infrared (FT-NIR) spectroscopy in conjunction with chemometrics modeling for in-line hot melt extrusion process monitoring. The obtained results suggested that inline FT-NIR analysis, along with a tailored NIR reflector, is a viable process analytical tool to monitor active pharmaceutical ingredient concentration as well as processing parameters.Entities:
Keywords: NIR spectroscopy; continuous manufacturing; hot melt extrusion (HME); process analytical technology (PAT)
Mesh:
Year: 2018 PMID: 29948985 PMCID: PMC6283664 DOI: 10.1208/s12249-018-1091-3