Effects of High-Flow Nasal Cannula on End-Expiratory Lung Impedance in Semi-Seated Healthy Subjects.

Gustavo A Plotnikow1, Arnaud W Thille2, Daniela N Vasquez3, Romina A Pratto4, Corina M Quiroga4, María E Andrich4, Javier H Dorado4, Ramiro S Gomez4, Pablo A D'Annunzio4, José L Scapellato3, Dante Intile3.   

Abstract

BACKGROUND: High-flow nasal cannula (HFNC) enables delivery of humidified gas at high flow while controlling the FIO2 . Although its use is growing in patients with acute respiratory failure, little is known about the impact of HFNC on lung volume. Therefore, we aimed to assess lung volume changes in healthy subjects at different flows and positions.
METHODS: This was a prospective physiological study performed in 16 healthy subjects. The changes in lung volumes were assessed by measuring end-expiratory lung impedance by using electrical impedance tomography. All the subjects successively breathed during 5 min in these following conditions: while in a supine position without HFNC (T0) and 3 measurements in a semi-seated position at 45° without HFNC (T1), and with HFNC at a flow of 30 L/min (T2), and 50 L/min (T3).
RESULTS: Compared with the supine position, the values of end-expiratory lung impedance significantly increased with the subjects in a semi-seated position. End-expiratory lung impedance significantly increased after HFNC initiation in subjects in a semi-seated position and further increased by increasing flow at 50 L/min. When taking the end-expiratory lung impedance measurement in subjects in a semi-seated position (T1) as reference, the differences among the medians of global end-expiratory lung impedance were statistically significant (P < .001), which amounted to 1.05 units in T1; 1.12 units in T2; and 1.44 units in T3 (P < .05 for all comparisons, Wilcoxon test). The breathing frequency did not differ between the supine and semi-seated position (T0 and T1) but significantly decreased after initiation of HFNC and further decreased at high flow. T0 and T1 were not different (P = .13); whereas there was a statistically significant difference among T1, T2, and T3 (P < .05, post hoc test with Bonferroni correction).
CONCLUSIONS: In healthy subjects, the semi-seated position and the use of HFNC increased end-expiratory lung impedance globally. These changes were accompanied by a significant decrease in the breathing frequency.
Copyright © 2018 by Daedalus Enterprises.

Entities:  

Keywords:  electrical impedance tomography; end-expiratory lung impedance; end-expiratory lung volume; high-flow devices; high-flow nasal cannula; oxygen inhalation therapy

Mesh:

Year:  2018        PMID: 29945910     DOI: 10.4187/respcare.06031

Source DB:  PubMed          Journal:  Respir Care        ISSN: 0020-1324            Impact factor:   2.258


  3 in total

1.  Clinical efficacy of high-flow nasal humidified oxygen therapy in patients with hypoxemia.

Authors:  Qiliang Hou; Zhigang Zhang; Ting Lei; Maozhou Gan; Xiangjun Wu; Weigang Yue; Bin Li; Lin Deng; Hongchang Gong
Journal:  PLoS One       Date:  2019-06-06       Impact factor: 3.240

2.  Validation of an Electronic Phenotyping Algorithm for Patients With Acute Respiratory Failure.

Authors:  Patrick Essay; Julia M Fisher; Jarrod M Mosier; Vignesh Subbian
Journal:  Crit Care Explor       Date:  2022-03-01

3.  Effect of postextubation high-flow nasal cannula therapy on lung recruitment and overdistension in high-risk patient.

Authors:  Rui Zhang; Huaiwu He; Long Yun; Xiang Zhou; Xu Wang; Yi Chi; Siyi Yuan; Zhanqi Zhao
Journal:  Crit Care       Date:  2020-03-06       Impact factor: 9.097

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.