Literature DB >> 29945320

A Rare Non-Hemolytic Case of Idiopathic Cold Agglutinin Disease.

Edip Erkus, Mehmet Z Kocak, Gulali Aktas, Mehmet Ozen, Burcin M Atak, Tuba T Duman, Buket K Tekce, Haluk Savli.   

Abstract

BACKGROUND: Cold agglutinin disease is a very rare condition associated with agglutination of erythrocytes in cold environment usually due to IgM type antibodies. Other than hemolytic anemias, it may interfere with routine hemogram tests due to miscalculation of red blood cell count (RBC) and other hemogram parameters calculated with involvement of RBC. Awareness of the condition is important to overcome laboratory errors.
METHODS: We studied a peripheral blood smear and repeated the hemogram test at 37°C to establish the diagnosis of cold agglutinin disease.
RESULTS: Initial hemogram test results of the fifty-eight year-old man was as follows: RBC: 1.34 M/µL, hemoglobin (Hb): 12.4 g/dL, hematocrit (Htc): 11.8%, mean corpuscular hemoglobin (MCH): 92.4 pg, and mean corpuscular hemoglobin concentration (MCHC): 105 gr/dL. Despite the standard indirect Coombs test being negative, repeated tests at room temperature was 4+. We suspected cold agglutinin disease and repeated the hemogram test using the Bain-Marie method at 37°C and the test results showed RBC: 3.4 M/µL, hemoglobin: 12.6 g/dL, hematocrit: 30.2%, MCH: 31.7 pg, and MCHC: 41.8 g/dL.
CONCLUSIONS: Inappropriate hemogram results may be a sign of underlying cold agglutinin disease. Hemolytic anemia not always accompanies the disease; however, cold exposure may trigger erythrocyte agglutination in vitro and may cause erratic laboratory results.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 29945320     DOI: 10.7754/Clin.Lab.2018.180114

Source DB:  PubMed          Journal:  Clin Lab        ISSN: 1433-6510            Impact factor:   1.138


  3 in total

1.  Analysis of preanalytical errors in a clinical chemistry laboratory: A 2-year study.

Authors:  Jerold C Alcantara; Bandar Alharbi; Yasser Almotairi; Mohammad Jahoor Alam; Abdel Rahim Mahmoud Muddathir; Khalid Alshaghdali
Journal:  Medicine (Baltimore)       Date:  2022-07-08       Impact factor: 1.817

2.  A Reference chart for clinical biochemical tests of hemolyzed serum samples.

Authors:  Jun Ni; Wenbo Zhu; Yanyang Wang; Xuefei Wei; Jingjing Li; Lu Peng; Kui Zhang; Bing Bai
Journal:  J Clin Lab Anal       Date:  2020-09-02       Impact factor: 2.352

3.  Resolution of serologic problems due to cold agglutinin mediated autoimmune hemolytic anemia and its transfusion decision.

Authors:  Qiming Ying; Dingfeng Lv; Xiaomei Fu; Shuanglu Shi; Luyan Chen; Yiwen He; Jing Yang; Shujun Yang; Qitian Mu
Journal:  J Clin Lab Anal       Date:  2021-07-03       Impact factor: 2.352

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.