Literature DB >> 29944509

Intrasubject Repeatability and Interdevice Agreement of Anterior Chamber Depth Measurements by Orbscan and Pentacam in Different Grades of Keratoconus.

Hassan Hashemi1, Amir Asharlous, Mohammad Aghazadeh Amiri, Abbasali Yekta, Shahroukh Ramin, Azadeh Taheri, Mohamadreza Aghamirsalim, Mehdi Khabazkhoob.   

Abstract

OBJECTIVES: To evaluate the repeatability of anterior chamber depth (ACD) measurements by Orbscan and Pentacam imaging devices in different grades of keratoconus.
METHODS: One examiner performed 3 consecutive ACD measurements with both devices on 74 eyes of 42 keratoconus patient. Repeatability was assessed using intrasession test-retest variability. Within-subject SD was determined for repeatability, and the coefficient of variation was calculated for each measurement. The intraclass correlation coefficient (ICC) was also determined to assess the variance of repeated data.
RESULTS: Overall, the three ACD measurements were not significantly different either with Pentacam or Orbscan. The ICC index values were greater than 90% with both devices, and it significantly reduced at higher grades of keratoconus with Pentacam. Interdevice differences were statistically significant. The interdevice agreement with ACD measurements was 0.981, and the agreement was lower at higher grades of keratoconus. The 95% limits of agreement between the 2 devices for ACD was from -0.19 to 0.04.
CONCLUSIONS: Our results indicate acceptable repeatability for ACD measurements with both Orbscan and Pentacam in keratoconus patients. The progression of keratoconus has no significant effect on repeatability results of these devices. The good agreement between them allows their interchangeable use.

Entities:  

Mesh:

Year:  2019        PMID: 29944509     DOI: 10.1097/ICL.0000000000000515

Source DB:  PubMed          Journal:  Eye Contact Lens        ISSN: 1542-2321            Impact factor:   2.018


  4 in total

1.  Repeatability of Corneal Densitometry Measurements using a Scheimpflug Camera in Healthy Normal Corneas.

Authors:  Mojgan Pakbin; Mehdi Khabazkhoob; Mohammad Pakravan; Akbar Fotouhi; Ebrahim Jafarzadehpur; Mohamadreza Aghamirsalim; Hassan Hashemi
Journal:  J Curr Ophthalmol       Date:  2022-04-16

2.  Predictive factors of the accelerated transepithelial corneal cross-linking outcomes in keratoconus.

Authors:  Mi Tian; Weijun Jian; Xiaoyu Zhang; Ling Sun; Yang Shen; Xingtao Zhou
Journal:  BMC Ophthalmol       Date:  2022-01-03       Impact factor: 2.209

3.  Repeatability and reproducibility of corneal higher-order aberrations measurements after small incision lenticule extraction using the Scheimpflug-Placido topographer.

Authors:  Rui Ning; Rongrong Gao; David P Piñero; Jun Zhang; Qingyi Gao; Yili Jin; Yiran Wang; Chenxiao Wang; Jinhai Huang
Journal:  Eye Vis (Lond)       Date:  2022-01-04

4.  Agreement in anterior segment measurements between swept-source and Scheimpflug-based optical biometries in keratoconic eyes: a pilot study.

Authors:  Evangelia Chalkiadaki; Panos S Gartaganis; Thomas Ntravalias; Ioannis Giannakis; Evangelos Manousakis; Efthymios Karmiris
Journal:  Ther Adv Ophthalmol       Date:  2022-03-31
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.