Literature DB >> 29940560

Cardiac Valve Annulus Diameters in Extremely Preterm Infants: A Cross-Sectional Echocardiographic Study.

Allard E van Ark1, Mirella C Molenschot1, Maria H Wesseling1, Willem B de Vries2, Jan L M Strengers1, Arthur Adams3, Johannes M P J Breur1.   

Abstract

BACKGROUND: With the increasing incidence of births of very preterm very-low-birth-weight infants, there is a demand for echocardiographic reference values of cardiac dimensions.
OBJECTIVES: The aim of this study was to provide reference values of cardiac valve annulus diameters in a cohort of extremely preterm very-low-birth-weight neonates and to correlate these with patient characteristics.
METHODS: Valve diameters of 376 infants of < 32 weeks' gestation and with a birth weight of ≤2,000 g were measured using 2-dimensional echocardiography. Correlations between valve diameters and patient characteristics (birth length/weight, body surface area, gestational age, and sex) were assessed. Birth weight was used to establish linear regression models. Inter- and intraobserver agreement was assessed through intraclass correlation coefficient (ICC) analysis.
RESULTS: Substantial variability was found (aortic valve mean [standard deviation; range]: 5.0 mm [0.6; 3.7-6.5]; pulmonic valve: 5.8 mm [0.8; 3.4-7.9]; mitral valve: 8.0 mm [1.0; 5.5-10.5]; tricuspid valve: 7.6 mm [1.2; 4.9-10.6]). There was a moderate correlation between birth weight and valve diameter (R2 aortic valve: 0.36; pulmonic valve: 0.20; mitral valve: 0.24; tricuspid valve: 0.24). Adequate intraobserver (ICC range 0.74-0.91) and interobserver agreement (ICC range 0.77-0.89) was found.
CONCLUSIONS: Our study provides ready-to-use reference values for cardiac valve annulus diameters for extremely preterm infants.
© 2018 The Author(s) Published by S. Karger AG, Basel.

Entities:  

Keywords:  Cardiac valves; Echocardiography; Extremely preterm infants; Low birth weight; Reference values

Mesh:

Year:  2018        PMID: 29940560      PMCID: PMC6191879          DOI: 10.1159/000488387

Source DB:  PubMed          Journal:  Neonatology        ISSN: 1661-7800            Impact factor:   4.035


  30 in total

1.  Development of Z-scores for fetal cardiac dimensions from echocardiography.

Authors:  C Schneider; B W McCrindle; J S Carvalho; L K Hornberger; K P McCarthy; P E F Daubeney
Journal:  Ultrasound Obstet Gynecol       Date:  2005-11       Impact factor: 7.299

2.  Two-dimensional echocardiographic valve measurements in healthy children: gender-specific differences.

Authors:  M V Zilberman; P R Khoury; R T Kimball
Journal:  Pediatr Cardiol       Date:  2005 Jul-Aug       Impact factor: 1.655

Review 3.  Prenatal diagnosis of critical congenital heart disease reduces risk of death from cardiovascular compromise prior to planned neonatal cardiac surgery: a meta-analysis.

Authors:  B J Holland; J A Myers; C R Woods
Journal:  Ultrasound Obstet Gynecol       Date:  2015-06       Impact factor: 7.299

4.  Cerebral oxygenation and echocardiographic parameters in preterm neonates with a patent ductus arteriosus: an observational study.

Authors:  Laura Dix; Mirella Molenschot; Johannes Breur; Willem de Vries; Daniel Vijlbrief; Floris Groenendaal; Frank van Bel; Petra Lemmers
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2016-03-31       Impact factor: 5.747

5.  Early end-tidal carbon monoxide levels, patency of the ductus arteriosus and regional cerebral oxygenation in preterm infants.

Authors:  Laura M L Dix; Cornelie A Blok; Petra M A Lemmers; Niek van der Aa; Mirella C Molenschot; Hendrik J Vreman; Tannette Krediet; Frank van Bel
Journal:  Neonatology       Date:  2013-12-19       Impact factor: 4.035

6.  Echocardiographic nomograms for ventricular, valvular and arterial dimensions in caucasian children with a special focus on neonates, infants and toddlers.

Authors:  Massimiliano Cantinotti; Marco Scalese; Bruno Murzi; Nadia Assanta; Isabella Spadoni; Pierluigi Festa; Vittoria De Lucia; Maura Crocetti; Marco Marotta; Sabrina Molinaro; Leo Lopez; Giorgio Iervasi
Journal:  J Am Soc Echocardiogr       Date:  2013-12-07       Impact factor: 5.251

7.  Mitral and tricuspid valve anular diameter in normal children determined by two-dimensional echocardiography.

Authors:  D H King; E O Smith; J C Huhta; H P Gutgesell
Journal:  Am J Cardiol       Date:  1985-03-01       Impact factor: 2.778

8.  Geometric method for measuring body surface area: a height-weight formula validated in infants, children, and adults.

Authors:  G B Haycock; G J Schwartz; D H Wisotsky
Journal:  J Pediatr       Date:  1978-07       Impact factor: 4.406

9.  Regression equations for calculation of z scores of cardiac structures in a large cohort of healthy infants, children, and adolescents: an echocardiographic study.

Authors:  Michael D Pettersen; Wei Du; Mary Ellen Skeens; Richard A Humes
Journal:  J Am Soc Echocardiogr       Date:  2008-04-11       Impact factor: 5.251

10.  Preterm birth and congenital heart defects: a population-based study.

Authors:  Enora Laas; Nathalie Lelong; Anne-Claire Thieulin; Lucile Houyel; Damien Bonnet; Pierre-Yves Ancel; Gilles Kayem; François Goffinet; Babak Khoshnood
Journal:  Pediatrics       Date:  2012-09-03       Impact factor: 7.124

View more
  1 in total

1.  Fetal cardiac parameters for predicting postnatal operation type of fetuses with tetralogy of Fallot.

Authors:  Suyeon Park; Hye-Sung Won; Rina Kim; Mijin Kim; Jeong Jin Yu; Chun Soo Park; Tae-Jin Yun; Yewon Jung; Usamah Al Harbi; Mi-Young Lee
Journal:  Cardiovasc Ultrasound       Date:  2022-02-21       Impact factor: 2.062

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.