Literature DB >> 29938501

Internal Calibration Potentiometric Aptasensors for Simultaneous Detection of Hg2+, Cd2+, and As3+ Based on a Screen-Printed Carbon Electrodes Array.

Wanxin Tang1, Zhenzhen Wang1, Juan Yu1, Fan Zhang1, Pingang He1.   

Abstract

An all-solid-state potentiometric aptasensor array based on a multichannel disposable screen-printed carbon electrode (SPCE) was demonstrated for the simultaneous detection of Hg2+, Cd2+, and As3+ by open circuit potential (OCP) technology. The potential of the channel with an internal calibration DNA sequence (IC-DNA) was employed as the internal calibration potential (ICP) to subtract the background signal generated by the detection system, providing a built-in correction methodology. As a result, the developed aptasensor array showed high sensitivity and accuracy for detecting Hg2+, Cd2+, and As3+ without mutual interference or interference from other ions. The linear response ranged from 2.5 pM to 2.5 μM, and the detection limits for Hg2+, Cd2+, and As3+ were 2.0, 0.62, and 0.17 pM, respectively. Furthermore, the potentiometric aptasensor array was successfully applied for the simultaneous detection of three ions in real samples. The results obtained from the developed approach agreed well with the results obtained from inductively coupled plasma mass spectrometry.

Entities:  

Year:  2018        PMID: 29938501     DOI: 10.1021/acs.analchem.7b04150

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  4 in total

Review 1.  From Small Molecules Toward Whole Cells Detection: Application of Electrochemical Aptasensors in Modern Medical Diagnostics.

Authors:  Robert Ziółkowski; Marta Jarczewska; Łukasz Górski; Elżbieta Malinowska
Journal:  Sensors (Basel)       Date:  2021-01-21       Impact factor: 3.576

2.  Recent Advances in Potentiometric Biosensing.

Authors:  Nicole L Walker; Anastasiya B Roshkolaeva; Andrei I Chapoval; Jeffrey E Dick
Journal:  Curr Opin Electrochem       Date:  2021-03-17

Review 3.  Bio- and Biomimetic Receptors for Electrochemical Sensing of Heavy Metal Ions.

Authors:  Angela Maria Stortini; Maria Antonietta Baldo; Giulia Moro; Federico Polo; Ligia Maria Moretto
Journal:  Sensors (Basel)       Date:  2020-11-28       Impact factor: 3.576

4.  A Co-Nanoparticles Modified Electrode for On-Site and Rapid Phosphate Detection in Hydroponic Solutions.

Authors:  Feng Xu; Peng Wang; Shiyuan Bian; Yuliang Wei; Deyi Kong; Huanqin Wang
Journal:  Sensors (Basel)       Date:  2021-01-05       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.