Literature DB >> 29936007

Improvements of Myocardial Deformation Assessment by Three-Dimensional Speckle-Tracking versus Two-Dimensional Speckle-Tracking Revealed by Cardiac Magnetic Resonance Tagging.

Mihaela S Amzulescu1, Hélène Langet2, Eric Saloux3, Alain Manrique4, Allison Slimani1, Pascal Allain5, Clotilde Roy1, Christophe de Meester1, Agnès Pasquet1, Oudom Somphone5, Mathieu De Craene5, David Vancraeynest1, Anne-Catherine Pouleur1, Jean-Louis Vanoverschelde1, Bernhard L Gerber6.   

Abstract

BACKGROUND: In prior work, the authors demonstrated that two-dimensional speckle-tracking (2DST) correlated well but systematically overestimated global longitudinal strain (LS) and circumferential strain (CS) compared with two-dimensional cardiac magnetic resonance tagging (2DTagg) and had poor agreement on a segmental basis. Because three-dimensional speckle-tracking (3DST) has recently emerged as a new, more comprehensive evaluation of myocardial deformation, this study was undertaken to evaluate whether it would compare more favorably with 2DTagg than 2DST.
METHODS: In a prospective two-center trial, 119 subjects (29 healthy volunteers, 63 patients with left ventricular dysfunction, and 27 patients with left ventricular hypertrophy) underwent 2DST, 3DST, and 2DTagg. Global, regional (basal, mid, and apical), and segmental (18 and 16 segments per patient) LS and CS by 2DST and 3DST were compared with 2DTagg using intraclass correlation coefficients (ICCs) and Bland-Altman analysis. Test-retest reproducibility of 3DST and 2DST was compared in 48 other patients.
RESULTS: Both global LS and CS by 3DST agreed better with 2DTagg (ICC = 0.89 and ICC = 0.83, P < .001 for both; bias = 0.5 ± 2.3% and 0.2 ± 3%) than 2DST (ICC = 0.65 and ICC = 0.55, P < .001 for both; bias = -5.5 ± 2.5% and -7 ± 5.3%). Unlike 2DST, 3DST did not overestimate deformation at the regional and particularly the apical levels and at the segmental level had lower bias (LS, 0.8 ± 2.8% vs -5.3 ± 2.4%; CS, -0.01 ± 2.8% vs -7 ± 2.8%, respectively) but similar agreement with 2DST (LS: ICC = 0.58 ± 0.16 vs 0.56 ± 0.12; CS: ICC = 0.58 ± 0.12 vs 0.51 ± 0.1) with 2DTagg. Finally, 3DST had similar global LS, but better global CS test-retest variability than 2DST.
CONCLUSIONS: Using 2DTagg as reference, 3DST had better agreement and less bias for global and regional LS and CS. At the segmental level, 3DST demonstrated comparable agreement but lower bias versus 2DTagg compared with 2DST. Also, test-retest variability for global CS by 3DST was better than by 2DST. This suggests that 3DST is superior to 2DST for analysis of global and regional myocardial deformation, but further refinement is needed for both 3DST and 2DST at the segmental level.
Copyright © 2018 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Magnetic resonance imaging; Speckle-tracking echocardiography; Strain; Three-dimensional; Two-dimensional

Mesh:

Year:  2018        PMID: 29936007     DOI: 10.1016/j.echo.2018.04.009

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  6 in total

1.  Displacement analysis of myocardial mechanical deformation (DIAMOND) reveals segmental susceptibility to doxorubicin-induced injury and regeneration.

Authors:  Junjie Chen; Yichen Ding; Michael Chen; Jonathan Gau; Nelson Jen; Chadi Nahal; Sally Tu; Cynthia Chen; Steve Zhou; Chih-Chiang Chang; Jintian Lyu; Xiaolei Xu; Tzung K Hsiai; René R Sevag Packard
Journal:  JCI Insight       Date:  2019-04-18

Review 2.  A review of current trends in three-dimensional analysis of left ventricular myocardial strain.

Authors:  Yosuke Nabeshima; Yoshihiro Seo; Masaaki Takeuchi
Journal:  Cardiovasc Ultrasound       Date:  2020-06-26       Impact factor: 2.062

3.  Myocardial strain imaging: review of general principles, validation, and sources of discrepancies.

Authors:  M S Amzulescu; M De Craene; H Langet; A Pasquet; D Vancraeynest; A C Pouleur; J L Vanoverschelde; B L Gerber
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2019-06-01       Impact factor: 6.875

4.  2D-echocardiography vs cardiac MRI strain: a prospective cohort study in patients with HER2-positive breast cancer undergoing trastuzumab.

Authors:  Nathalie I Bouwer; Crista Liesting; Marcel J M Kofflard; Jasper J Brugts; Marc C J Kock; Jos J E M Kitzen; Mark-David Levin; Eric Boersma
Journal:  Cardiovasc Ultrasound       Date:  2021-11-09       Impact factor: 2.062

5.  Evaluation of Cardiac Function before and after PAD Regimen in Patients with Multiple Myeloma by Three-Dimensional Speckle Tracking Imaging.

Authors:  Dongliang Chen; Zining Yan; Li Fan; Yifei Rui
Journal:  J Healthc Eng       Date:  2022-01-27       Impact factor: 2.682

6.  A systematic review and meta-analysis of the normal reference value of the longitudinal left atrial strain by three dimensional speckle tracking echocardiography.

Authors:  Reza Mohseni-Badalabadi; Tayebeh Mirjalili; Arash Jalali; Tahereh Davarpasand; Ali Hosseinsabet
Journal:  Sci Rep       Date:  2022-03-15       Impact factor: 4.379

  6 in total