Literature DB >> 29929053

Curvelet Transform-based volume fusion for correcting signal loss artifacts in Time-of-Flight Magnetic Resonance Angiography data.

Ahmadreza Baghaie1, Susanne Schnell2, Ali Bakhshinejad3, Mojtaba F Fathi3, Roshan M D'Souza3, Vitaliy L Rayz4.   

Abstract

Flow fields in cerebral aneurysms can be measured in vivo with phase-contrast MRI (4D Flow MRI), providing 3D anatomical magnitude images as well as 3-directional velocities through the cardiac cycle. The low spatial resolution of the 4D Flow MRI data, however, requires the images to be co-registered with higher resolution angiographic data for better segmentation of the blood vessel geometries to adequately quantify relevant flow descriptors such as wall shear stress or flow residence time. Time-of-Flight Magnetic Resonance Angiography (TOF MRA) is a non-invasive technique for visualizing blood vessels without the need to administer contrast agent. Instead TOF uses the blood flow-related enhancement of unsaturated spins entering into an imaging slice as means to generate contrast between the stationary tissue and the moving blood. Because of the higher resolutions, TOF data are often used to assist with the segmentation process needed for the flow analysis and Computational Fluid Dynamics (CFD) modeling. However, presence of slow moving and recirculating blood flow such as in brain aneurysms, especially regions where the blood flow is not perpendicular to the image plane, causes signal loss in these regions. In this work a 3D Curvelet Transform-based image fusion approach is proposed for signal loss artifact reduction of TOF volume data. Experiments show the superiority of the proposed approach in comparison to other multi-resolution 3D Wavelet-based image fusion methodologies. The proposed approach can further facilitate model-based fluid analysis and pre/post-operative treatment of patients with brain aneurysms.
Copyright © 2018 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  4D flow MRI; Curvelet transform; Phase contrast magnetic resonance imaging (PC-MRI); Time-of-flight magnetic resonance angiography (TOF MRA)

Mesh:

Year:  2018        PMID: 29929053      PMCID: PMC6077095          DOI: 10.1016/j.compbiomed.2018.06.008

Source DB:  PubMed          Journal:  Comput Biol Med        ISSN: 0010-4825            Impact factor:   4.589


  24 in total

1.  Improved optimization for the robust and accurate linear registration and motion correction of brain images.

Authors:  Mark Jenkinson; Peter Bannister; Michael Brady; Stephen Smith
Journal:  Neuroimage       Date:  2002-10       Impact factor: 6.556

2.  Image quality assessment: from error visibility to structural similarity.

Authors:  Zhou Wang; Alan Conrad Bovik; Hamid Rahim Sheikh; Eero P Simoncelli
Journal:  IEEE Trans Image Process       Date:  2004-04       Impact factor: 10.856

Review 3.  Medical image registration: a review.

Authors:  Francisco P M Oliveira; João Manuel R S Tavares
Journal:  Comput Methods Biomech Biomed Engin       Date:  2012-03-22       Impact factor: 1.763

4.  Multidimensional directional filter banks and surfacelets.

Authors:  Yue M Lu; Minh N Do
Journal:  IEEE Trans Image Process       Date:  2007-04       Impact factor: 10.856

5.  Encoding strategies for three-direction phase-contrast MR imaging of flow.

Authors:  N J Pelc; M A Bernstein; A Shimakawa; G H Glover
Journal:  J Magn Reson Imaging       Date:  1991 Jul-Aug       Impact factor: 4.813

6.  Accelerated dual-venc 4D flow MRI for neurovascular applications.

Authors:  Susanne Schnell; Sameer A Ansari; Can Wu; Julio Garcia; Ian G Murphy; Ozair A Rahman; Amir A Rahsepar; Maria Aristova; Jeremy D Collins; James C Carr; Michael Markl
Journal:  J Magn Reson Imaging       Date:  2017-02-02       Impact factor: 4.813

7.  Two-dimensional time-of-flight MR angiography of the lower extremities: artifacts and pitfalls.

Authors:  J A Kaufman; D McCarter; S C Geller; A C Waltman
Journal:  AJR Am J Roentgenol       Date:  1998-07       Impact factor: 3.959

8.  The AAPM/RSNA physics tutorial for residents. An introduction to MR angiography.

Authors:  D Saloner
Journal:  Radiographics       Date:  1995-03       Impact factor: 5.333

9.  Robust 4D flow denoising using divergence-free wavelet transform.

Authors:  Frank Ong; Martin Uecker; Umar Tariq; Albert Hsiao; Marcus T Alley; Shreyas S Vasanawala; Michael Lustig
Journal:  Magn Reson Med       Date:  2014-02-18       Impact factor: 4.668

Review 10.  4D flow imaging with MRI.

Authors:  Zoran Stankovic; Bradley D Allen; Julio Garcia; Kelly B Jarvis; Michael Markl
Journal:  Cardiovasc Diagn Ther       Date:  2014-04
View more