Literature DB >> 29927208

Comparison of Sagittal Balance between Radiofrequency Targeted Vertebral Augmentation and Balloon Kyphoplasty in Treatment of Vertebral Compression Fracture: A Retrospective Study.

Werasak Sutipornpalangkul, Lester Zambrana, Arianna Gianakos, Joseph M Lane.   

Abstract

Objective: To compare the effectiveness of high viscosity cement radiofrequency targeted vertebral augmentation (RF-TVA) and balloon kyphoplasty on spinal sagittal balance through radiologic evaluation. Material and Method: The present retrospective study included patients whom underwent either balloon kyphoplasty utilizing the Kyphon system or RF-TVA utilizing the DFine system between 2007 and 2014. Medical record reviews included demographic data and radiographic findings including pre- and post-operative lateral radiographs of the whole spine and post-operative computerized topography. All spinal sagittal alignment parameters such as pelvic incidence (PI), sacral slope (SS), pelvic tilt (PT), lumbar lordosis (LL), sagittal vertical axis (SVA), and spinosacral angle (SSA) were measured and evaluated.
Results: Thirty-three vertebral compression fracture (VCF) patients were included in the present study. Sixteen of them underwent RF-TVA and 17 underwent balloon kyphoplasty. There were no significant differences in age, gender, and pre-operative spinal sagittal alignment parameters between these two groups of patients. In the RF-TVA group, there were no significant differences in percent of vertebral collapse and kyphotic angle between pre-and post-operative radiographs. In the balloon kyphoplasty group, there were significant improvement in both percent of vertebral collapse and kyphotic angle. The balloon kyphoplasty group also showed a statistically significant change in pelvic tilt (p = 0.02). Neither group demonstrated statistically significant changes in any other spinal sagittal alignment parameters (p>0.05).
Conclusion: The RF-TVA and balloon kyphoplasty did not play a role in improving the whole spine alignment in the treatment of VCF. However, balloon kyphoplasty did demonstrate regional improvement of the VCF.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 29927208

Source DB:  PubMed          Journal:  J Med Assoc Thai        ISSN: 0125-2208


  2 in total

1.  Percutaneous kyphoplasty for osteoporotic vertebral compression fractures improves spino-pelvic alignment and global sagittal balance maximally in the thoracolumbar region.

Authors:  Zhong Cao; Guodong Wang; Wenpeng Hui; Bo Liu; Zhiyong Liu; Jianmin Sun
Journal:  PLoS One       Date:  2020-01-30       Impact factor: 3.240

2.  Comparison of Percutaneous Kyphoplasty With or Without Posterior Pedicle Screw Fixation on Spinal Sagittal Balance in Elderly Patients With Severe Osteoporotic Vertebral Compression Fracture: A Retrospective Study.

Authors:  Quan Zhou; Junxin Zhang; Hao Liu; Wei He; Lei Deng; Xinfeng Zhou; Huilin Yang; Tao Liu
Journal:  Front Surg       Date:  2022-02-18
  2 in total