Literature DB >> 29925710

Effects of scanning technique on in vitro performance of CAD/CAM-fabricated fiber posts.

Nino Tsintsadze1, Jelena Juloski1,2, Michele Carrabba1, Cecilia Goracci1, Alessandro Vichi1, Simone Grandini1, Marco Ferrari1.   

Abstract

This study assessed push-out strength, cement layer thickness, and interfacial nanoleakage of luted fiber posts fabricated with computer-aided design/computer-assisted manufacture (CAD/CAM) technology after use of 1 of 3 scanning techniques, namely, direct scanning of the post space (DS), scanning of a polyether impression of the post space (IS), and scanning of a plaster model of the post space (MS). Thirty premolars were randomly assigned to three groups corresponding to the scanning technique. Posts were computer-designed and milled from experimental fiber-reinforced composite blocks. The mean (±SD) values for push-out strength and cement thickness were 17.1 ± 7.7 MPa and 162 ± 24 μm, respectively, for DS, 10.7 ± 4.6 MPa and 187 ± 50 μm for IS, and 12.0 ± 7.2 MPa and 258 ± 78 μm for MS specimens. Median (interquartile range) interfacial nanoleakage scores were 3 (2-4) for DS, 2.5 (2-4) for IS, and 3 (2-4) for MS. Post retention was better for fiber posts fabricated by DS technique than for those fabricated by IS and MS. Cement thickness did not differ between DS and IS specimens, but the cement layer was significantly thicker in the MS group than in the other two groups. Scanning technique did not affect sealing ability, as the three groups had comparable nanoleakage values.

Entities:  

Keywords:  CAD/CAM; cement thickness; fiber post; nanoleakage; post retention; scanning techniques

Mesh:

Year:  2018        PMID: 29925710     DOI: 10.2334/josnusd.17-0254

Source DB:  PubMed          Journal:  J Oral Sci        ISSN: 1343-4934            Impact factor:   1.556


  4 in total

1.  Accuracy of Digital Impression Taking with Intraoral Scanners and Fabrication of CAD/CAM Posts and Cores in a Fully Digital Workflow.

Authors:  Robert Leven; Alexander Schmidt; Roland Binder; Marian Kampschulte; Jonas Vogler; Bernd Wöstmann; Maximiliane Amelie Schlenz
Journal:  Materials (Basel)       Date:  2022-06-13       Impact factor: 3.748

Review 2.  Customized Post and Cores Fabricated with CAD/CAM Technology: A Literature Review.

Authors:  Faisal D Al-Qarni
Journal:  Int J Gen Med       Date:  2022-05-06

3.  CAD/CAM Customized Glass Fiber Post and Core With Digital Intraoral Impression: A Case Report.

Authors:  Antonio Libonati; Virginia Di Taranto; Gianni Gallusi; Edoardo Montemurro; Vincenzo Campanella
Journal:  Clin Cosmet Investig Dent       Date:  2020-02-10

4.  In vitro Results of Scanning Technique on Assessing Cement Thickness and Interfacial Nanoleakage of Luted CAD/CAM-Fabricated Fiber Posts.

Authors:  Sunil Kumar Vaddamanu; Rajesh Vyas; Shashit Shetty Bavabeedu; Suraj Arora; Bhumika Kamal Badiyani; Amit Kumar
Journal:  J Pharm Bioallied Sci       Date:  2021-06-05
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.