Literature DB >> 29925094

Wearable Cardioverter-Defibrillators following Cardiac Surgery-A Single-Center Experience.

Jan Heimeshoff1, Constanze Merz1, Marcel Ricklefs1, Felix Kirchhoff1, Axel Haverich1, Christoph Bara1, Christian Kühn1.   

Abstract

BACKGROUND: A wearable cardioverter-defibrillator (WCD) can terminate ventricular fibrillation and ventricular tachycardias via electrical shock and thus give transient protection from sudden cardiac death. We investigated its role after cardiac surgery.
METHODS: We retrospectively analyzed all patients who were discharged with a WCD from cardiac surgery department. The WCD was prescribed for patients with a left ventricular ejection fraction (LVEF) of ≤35% or an explanted implantable cardioverter-defibrillator (ICD).
RESULTS: A total of 100 patients were included in this study, the majority (n = 59) had received coronary artery bypass graft surgery. The median wearing time of a WCD patient was 23.5 hours per day. LVEF was 28.9 ± 8% after surgery and improved in the follow-up to 36.7 ± 11% (p < 0.001). Three patients were successfully defibrillated. Ten patients experienced ventricular tachycardias. No inappropriate shocks were given. An ICD was implanted in 25 patients after the WCD wearing period.
CONCLUSION: Ventricular arrhythmias occurred in 13% of the investigated patients. LVEF improved significantly after 3 months, and thus a permanent ICD implantation was avoided in several cases. Sternotomy did not impair wearing time of the WCD. A WCD can effectively protect patients against ventricular tachyarrhythmias after cardiac surgery. Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Year:  2018        PMID: 29925094     DOI: 10.1055/s-0038-1660802

Source DB:  PubMed          Journal:  Thorac Cardiovasc Surg        ISSN: 0171-6425            Impact factor:   1.827


  3 in total

Review 1.  [Wearable defibrillator : Current evidence].

Authors:  David Duncker; Christian Veltmann
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2018-10-24

2.  Experience with a Wearable Cardioverter-defibrillator in 436 Patients.

Authors:  Herbert Nägele; Eike Groene; Daniel Stierle; Matin Ali Khan; Matthias P Nägele
Journal:  J Innov Card Rhythm Manag       Date:  2022-01-15

3.  Wearable cardioverter defibrillator multicentre experience in a large cardiac surgery cohort at transient risk of sudden cardiac death.

Authors:  Christian Kuehn; Stefan Ruemke; Philipp Rellecke; Artur Lichtenberg; Dominik Joskowiak; Christian Hagl; Mohamed Hassan; Rainer G Leyh; Stefan Erler; Jens Garbade; Sandra Eifert; Philippe Grieshaber; Andreas Boening; Torsten Doenst; Ilia Velichkov; Tomas Madej; Michael Knaut; Andreas Hain; Heiko Burger
Journal:  Eur J Cardiothorac Surg       Date:  2022-05-02       Impact factor: 4.534

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.