Performance of a Factory-Calibrated Real-Time Continuous Glucose Monitoring System Utilizing an Automated Sensor Applicator.

Viral N Shah1, Lori M Laffel2, R Paul Wadwa1, Satish K Garg1.   

Abstract

BACKGROUND: This study assessed the accuracy of a factory-calibrated 10-day real-time continuous glucose monitoring (CGM) system (G6), which includes an automated sensor applicator.
METHODS: Seventy-six participants with insulin-treated diabetes were enrolled at four U.S. sites as part of a larger study of G6 system performance. In-clinic visits for frequent comparative blood glucose measurements using a reference instrument (YSI) were conducted on days 1, 4-5, 7, and/or 10 of system use. Accuracy evaluation included the proportion of CGM values that were within ±20% of YSI reference value for glucose levels >100 mg/dL and ±20 mg/dL for YSI glucose levels ≤100 mg/dL (%20/20), the analogous %15/15 and %30/30, and the mean absolute relative difference (MARD) between temporally matched CGM and YSI values. Participants calibrated the systems once daily. Raw sensor data were reprocessed using assigned sensor codes and a factory-calibration algorithm.
RESULTS: Reprocessed data from 62 participants (25 adults and 37 children and adolescents of ages 6-17 years; 3532 YSI-CGM pairs) were analyzed. The G6 system's overall %20/20 was 93.9% (adults, 92.5%; children and adolescents, 96.2%), its %15/15 was 83.3% (adults, 78.3%; children and adolescents, 91.1%), and its MARD was 9.0% (adults, 9.8%; children and adolescents, 7.7%). Overall day-1 %20/20 accuracy was 92.2%, %15/15 was 81.5%, and MARD was 9.3%. Accuracy was maintained across 10 days of use and various glucose concentration ranges in both adults and children and adolescents.
CONCLUSIONS: The G6 system utilizing an automated sensor applicator provides accurate glucose readings in adults and children and adolescents throughout the 10-day sensor life.

Entities:  

Keywords:  Advanced algorithm; Clinical accuracy; Continuous glucose monitoring; Factory-calibrated; Glucose sensor performance; MARD

Mesh:

Substances:

Year:  2018        PMID: 29923775      PMCID: PMC6422005          DOI: 10.1089/dia.2018.0143

Source DB:  PubMed          Journal:  Diabetes Technol Ther        ISSN: 1520-9156            Impact factor:   6.118


  44 in total

1.  Use of Artificial Intelligence to Improve Diabetes Outcomes in Patients Using Multiple Daily Injections Therapy.

Authors:  Gregory P Forlenza
Journal:  Diabetes Technol Ther       Date:  2019-06       Impact factor: 6.118

2.  A Clinical Guide to Advanced Diabetes Devices and Closed-Loop Systems Using the CARES Paradigm.

Authors:  Laurel H Messer; Cari Berget; Gregory P Forlenza
Journal:  Diabetes Technol Ther       Date:  2019-05-29       Impact factor: 6.118

3.  Safety and Accuracy of Factory-Calibrated Continuous Glucose Monitoring in Pediatric Patients Undergoing Hematopoietic Stem Cell Transplantation.

Authors:  Jenna Sopfe; Tim Vigers; Laura Pyle; Roger H Giller; Gregory P Forlenza
Journal:  Diabetes Technol Ther       Date:  2020-03-17       Impact factor: 6.118

4.  Continuous Glucose Monitoring Predicts Progression to Diabetes in Autoantibody Positive Children.

Authors:  Andrea K Steck; Fran Dong; Iman Taki; Michelle Hoffman; Kimber Simmons; Brigitte I Frohnert; Marian J Rewers
Journal:  J Clin Endocrinol Metab       Date:  2019-08-01       Impact factor: 5.958

5.  Continuous glucose monitoring in the neonatal intensive care unit: not quite ready for 'plug and play'.

Authors:  Teri L Hernandez; William W Hay; Paul Joseph Rozance
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2018-11-13       Impact factor: 5.747

6.  A Head-to-Head Comparison Study of the First-Day Performance of Two Factory-Calibrated CGM Systems.

Authors:  Douglas Denham
Journal:  J Diabetes Sci Technol       Date:  2020-01-08

7.  Benefits and Barriers of Continuous Glucose Monitoring in Young Children with Type 1 Diabetes.

Authors:  Marisa E Hilliard; Wendy Levy; Barbara J Anderson; Amanda L Whitehouse; Persis V Commissariat; Kara R Harrington; Lori M Laffel; Kellee M Miller; Michelle Van Name; William V Tamborlane; Daniel J DeSalvo; Linda A DiMeglio
Journal:  Diabetes Technol Ther       Date:  2019-07-09       Impact factor: 6.118

8.  Factory-Calibrated Continuous Glucose Monitoring: How and Why It Works, and the Dangers of Reuse Beyond Approved Duration of Wear.

Authors:  Gregory P Forlenza; Taisa Kushner; Laurel H Messer; R Paul Wadwa; Sriram Sankaranarayanan
Journal:  Diabetes Technol Ther       Date:  2019-02-28       Impact factor: 6.118

9.  Accuracy of a Factory-Calibrated, Real-Time Continuous Glucose Monitoring System During 10 Days of Use in Youth and Adults with Diabetes.

Authors:  R Paul Wadwa; Lori M Laffel; Viral N Shah; Satish K Garg
Journal:  Diabetes Technol Ther       Date:  2018-06-14       Impact factor: 6.118

Review 10.  Continuous Glucose Monitoring Integration in Clinical Practice: A Stepped Guide to Data Review and Interpretation.

Authors:  Grazia Aleppo; Kimberly Webb
Journal:  J Diabetes Sci Technol       Date:  2018-11-19
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.