Abstract
BACKGROUND: Evidences suggest that central hemodynamics indexes are independent predictors of future cardiovascular events and all-cause mortality. Multiple factors have been pointed to have potential influence on central aortic function: height, heart rate, left ventricular ejection duration and blood pressure level. Data related to the influence of gender and postmenopausal status on aortic waveform reflection is scarce. We aim to evaluate the impact of gender and menopause on central blood pressure of hypertensive patients.Entities:
Keywords: Arterial hypertension; Arterial stiffness; Augmentation index; Central aortic blood pressure; Menopause; Pulse wave reflection
Mesh:
Year: 2018 PMID: 29921220 PMCID: PMC6008932 DOI: 10.1186/s12872-018-0855-8
Source DB: PubMed Journal: BMC Cardiovasc Disord ISSN: 1471-2261 Impact factor: 2.298
Fig. 1Flow chart of the study population
Clinical characteristics distributed by gender
| Variables | men ( | women ( |
|
|---|---|---|---|
| Age (years) | 49.7 ± 10.5 | 52.6 ± 11.0 | 0.15 |
| SBP (mmHg) | 137 ± 20 | 145 ± 26 | 0.06 |
| DBP (mmHg) | 86 ± 12 | 87 ± 15 | 0.60 |
| HR | 71.4 ± 13 | 68.2 ± 11.9 | 0.18 |
| Weight (kg) | 85.3 ± 11.4 | 76.2 ± 14.0 | < 0.01* |
| Height (m) | 1.72 ± 0.08 | 1.59 ± 0.06 | < 0.01* |
| Hypertension time (years) | 9.4 ± 7.1 | 10.8 ± 8.6 | 0.35 |
| AIx (%) | 20.1 ± 11.7 | 32.7 ± 9.8 | < 0.01* |
| AIx75 (%) | 18.3 ± 9.4 | 29.6 ± 6.7 | < 0.01* |
| C_SP (mmHg) | 125 ± 23 | 136 ± 30 | 0.03* |
| C_DP (mmHg) | 88 ± 15 | 88 ± 16 | 0.90 |
SPB systolic blood pressure, DBP diastolic blood pressure, HR heart rate, AIx aortic augmentation index, AIx75 aortic augmentation index adjusted for heart rate of 75, C_SP central systolic blood pressure, C_DP central diastolic blood pressure. (*) Differences in AIx (22.2 ± 12.7 vs 30.9 ± 12.2) and AIx75 (20.5 ± 9.41 vs 27.7 ± 8.12) persist even after adjustments for: height 1.64 m, weight 80.1Kg, SBP 142 mmHg p < 0.01
Fig. 2Values of aortic augmentation index (AIx) and AIx adjusted for a heart rate of 75 (AIx75) according to respective group. (m:male; f:female). a) group 1 vs. group 2 and group 4 (p < 0.01); b) group 2 vs. group 1 and group 4 (p < 0.01); c) group 3 vs. group 4 (p < 0.01); d) group 4 vs. all (p < 0.01); e) group 1 vs. all (p < 0.01);f) group 3 vs. group 1 and group 4 (p < 0.01)
Fig. 3Values of carotid diameter and distention according to respective group. (m:male; f:female). a) group 1 vs. group 3 and group 4 (p < 0.01);b) group 2 vs. all (p < 0.01);c) group 2 vs. group 3 and group 4