Literature DB >> 29912740

Homograft Versus Conventional Prosthesis for Surgical Management of Aortic Valve Infective Endocarditis: A Systematic Review and Meta-analysis.

Bobby Yanagawa1, Amine Mazine1, Derrick Y Tam1, Peter Jüni, Deepak L Bhatt2, Stephen Spindel3, John D Puskas3, Subodh Verma1, Jan O Friedrich.   

Abstract

OBJECTIVE: Surgical management of aortic valve infective endocarditis (IE) with cryopreserved homograft has been associated with lower risk of recurrent IE, but there is equipoise with regard to the optimal prosthesis. This systematic review and meta-analysis were performed to compare outcomes between homograft and conventional prosthesis for aortic valve IE.
METHODS: We searched MEDLINE database to September 2017 for studies comparing homograft versus conventional prosthesis. The main outcomes were all-cause mortality, recurrent IE, and reoperation.
RESULTS: There were 18 included comparative observational studies with 2232 patients (median follow up = 5 [interquartile range: 2-7] years, 30% prosthetic valve endocarditis); four studies were adjusted for baseline differences. There were no differences in perioperative mortality or stroke despite a greater proportion of staphylococcal endocarditis, abscess, and root replacements but less multivalve involvement in the homograft group. Long-term outcomes of all-cause mortality [incidence rate ratio (IRR) = 1.03, 95% confidence interval (CI) = 0.81-1.31, P = 0 .83, for unmatched, and IRR = 0.82, 95% CI = 0.36-1.84, P = 0.63, for matched studies], recurrent endocarditis (IRR = 1.01, 95% CI = 0.53-1.93, P = 0.96, for unmatched, and IRR = 1.04, 95% CI = 0.49-2.19, P = 0.92, for matched studies), and reoperation (IRR = 1.60, 95% CI = 0.80-3.21, P = 0.18, for unmatched, and IRR = 3.17, 95% CI = 0.52-19.44, P = 0.21, for matched studies) were not different comparing homograft versus conventional prosthesis. There was a significantly increased need for reoperation with homograft versus mechanical prosthetic valves, but this comparison was based on limited data.
CONCLUSIONS: Homografts and conventional prostheses offer similar survival and freedom from recurrent endocarditis and reoperation for aortic valve IE. Homografts may be associated with greater risk of reoperation compared with mechanical valves.

Entities:  

Mesh:

Year:  2018        PMID: 29912740     DOI: 10.1097/IMI.0000000000000510

Source DB:  PubMed          Journal:  Innovations (Phila)        ISSN: 1556-9845


  4 in total

1.  Homograft Versus Valves and Valved Conduits for Extensive Aortic Valve Endocarditis with Aortic Root Involvement/Destruction: A Systematic Review and Meta-Analysis.

Authors:  Michael L Williams; John D L Brookes; Joseph S Jaya; Eren Tan
Journal:  Aorta (Stamford)       Date:  2022-08-07

2.  A 20-year experience with cryopreserved allografts as the valve replacement of choice in aortic root reconstruction for destructive endocarditis with abscess formation.

Authors:  Afram Yousif; Khaldoun Ali; Marcel Anssar; Wolfgang Harringer; Aschraf El-Essawi; René Brouwer
Journal:  Interact Cardiovasc Thorac Surg       Date:  2022-07-09

3.  Infective Endocarditis After Surgical and Transcatheter Aortic Valve Replacement: A State of the Art Review.

Authors:  Sophia L Alexis; Aaqib H Malik; Isaac George; Rebecca T Hahn; Omar K Khalique; Karthik Seetharam; Deepak L Bhatt; Gilbert H L Tang
Journal:  J Am Heart Assoc       Date:  2020-08-08       Impact factor: 5.501

Review 4.  Pathology of the Aorta and Aorta as Homograft.

Authors:  Gaetano Thiene; Cristina Basso; Mila Della Barbera
Journal:  J Cardiovasc Dev Dis       Date:  2021-06-29
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.