Literature DB >> 29912714

Legionnaires' Disease Outbreak on a Merchant Vessel, Indian Ocean, Australia, 2015.

Timothy J J Inglis, Chantal Spittle, Hilary Carmichael, Jaala Downes, Marilina Chiari, Adrian McQueen-Mason, Adam J Merritt, Meredith Hodge, Ronan J Murray, Gary K Dowse.   

Abstract

Two cases of Legionnaires' disease and 1 of Pontiac fever occurred among the crew of a merchant ship operating off the shores of Australia. PCR assays identified potential sources in the ship's cabins. Modification of maritime regulations for Legionnaires' disease prevention in commercial vessels is needed for nonpassenger merchant ships.

Entities:  

Keywords:  Australia; Indian Ocean; Legionella pneumophila; Legionnaires’ disease; PCR; Pontiac fever; bacteria; biofilm; cruise; deployable microbiology; environmental control; fomite; health threat assessment; merchant ship; occupational risk; outbreak investigation; pneumonia; pneumothorax; reservoir; respiratory; vessel

Mesh:

Year:  2018        PMID: 29912714      PMCID: PMC6038751          DOI: 10.3201/eid2407.171978

Source DB:  PubMed          Journal:  Emerg Infect Dis        ISSN: 1080-6040            Impact factor:   6.883


The risk for Legionnaires’ disease (LD) is known on cruise liners (–) and is matched by recommendations for preventive measures (,). Environmental sources of Legionella pneumophila in ships are prone to transmit LD over several years through resistance to decontamination (,). As opposed to cruise liners, there are few reports of LD on working vessels, where occupational health risks differ (). Legionella was detectable in potable water systems on 58% of 350 merchant vessels in a recent survey (). There was no established precedent for environmental risk assessment or control when 2 LD cases occurred on a merchant ship off the northwestern Australian Indian Ocean coast in 2015. We therefore conducted an extended field investigation.

The Study

The first LD case-patient on the merchant ship sought treatment at the nearest hospital emergency department, and provided no alternative exposure source. After laboratory confirmation of this case, the crew disembarked and the vessel was required to lie at anchor offshore. After emergency control measures by a private contractor, we obtained information on the ship’s plumbing, including potable, fresh, and hot water systems, water storage, air conditioning; food preparation areas, and sleeping quarters. We then boarded the ship for environmental investigation on August 27, 2015, to collect samples from potential fomites around the vessel at 33 locations, including cabins and potable water outlets. We collected PCR swab samples in duplicate from inside showerheads and sink faucets (also known as mixer taps) aerators in sleeping quarters and food preparation areas, including those used by LD case-patients and their neighbors. The contractor disinfected the water system by using super chlorination the next day, and collected a second environmental sample series on September 4. Additional targeted control measures included replacement of showerheads and removal of faucet aerators from cabins. We collected a series of PCR swab samples from original test locations on October 12 to assess the residual health threat, and tested 24 of these samples on the ship (). Duplicate samples were then tested in the reference laboratory (). We analyzed showerheads removed from cabins (Figure 1). We tested samples of the inside surface of each showerhead and its O-ring gaskets by using PCR assays. We collected swab samples from potential reservoirs and tested for Legionella species: the O-rings; rinse samples from showerhead parts in sterile 0.08% NaCl solution for Legionella species; peptone water washings, showerhead contents, debris from a thermal mixing valve, fresh and pre–UV-treated water, showerheads, air conditioners, and faucets from cabins (). We identified presumptive Legionella cultures on MWY and BMPA agars by using Legionella Latex Agglutination antisera (Oxoid; ThermoFisher Scientific Australia Pty Ltd, Scoresby, Melbourne, Victoria, Australia), and cultured for amoeba on showerhead rinse specimens. Detailed methods are provided in Technical Appendix Part 1.
Figure 1

Dismantled showerhead from nonpassenger merchant vessel showing multiple inner parts, including 7 O-rings, all of which were in contact with water passing through shower, Australia, 2015.

Dismantled showerhead from nonpassenger merchant vessel showing multiple inner parts, including 7 O-rings, all of which were in contact with water passing through shower, Australia, 2015. In August 2015, the Western Australia Department of Health was notified of Legionnaires’ disease confirmed by L. pneumophila serogroup 1 urinary antigen test in a member of the vessel’s crew (case-patient 1), and was informed that other crew members had mild febrile respiratory illness (Table 1). Later that day, another crew member, who had symptoms of severe bilateral pneumonia and pneumothorax, arrived at the regional hospital and required aeromedical evacuation for intensive care (case-patient 2). LD was confirmed by urinary antigen testing and PCR assay on bronchial washings. Other crew members who had nonpneumonic respiratory and other symptoms were investigated for legionellosis by using urinary antigen tests and serologic tests which proved negative, except in case-patient 3, who had L. pneumophila seroconversion and Pontiac fever that did not require hospital admission. The 3 cases all satisfied Australian LD case definitions (). Case-patients 1 and 2 occupied adjacent cabins and case-patient 3 was 2 cabins away from case-patient 2 (Figure 2).
Table 1

Summary of confirmed legionellosis cases and results of environmental PCR testing in the case-patients’ merchant vessel cabins, August 2015*

Case-patient
Age, y
Onset
Infection
Hospital
UAT
Serology
PCR†
Cabin no.
Cabin samples (Aug 27)
Shower water
Shower-head swab
Bathroom sink faucet
154Aug 12 Lower respiratoryRegional+_+22+_+
255Aug 19Lower respiratoryTertiary+_+18+++
348Aug 10Mild respiratoryNot required_Conversion (0–2,048)_29NA‡NA‡NA‡

*NA, not available; UAT, urinary antigen test; +, positive; –-, negative.
†PCR-positive Legionella pneumophila. 
‡Cabin in use on August 27, 2015. Water from hand basin faucet collected on August 20 by private agency was culture negative.

Figure 2

Accommodation deck plan, Australia, 2015. Cabins (n = 10) and other rooms (ACU, air conditioning unit) from which environmental samples were collected on August 27, 2015 are indicated in dark gray. PCR-positive locations are indicated by red semicircles; upper, shower water or swab; lower, mixer tap water or swab. The 3 case-patients occupied cabins 18, 22, and 29.

*NA, not available; UAT, urinary antigen test; +, positive; –-, negative.
†PCR-positive Legionella pneumophila. 
‡Cabin in use on August 27, 2015. Water from hand basin faucet collected on August 20 by private agency was culture negative. Accommodation deck plan, Australia, 2015. Cabins (n = 10) and other rooms (ACU, air conditioning unit) from which environmental samples were collected on August 27, 2015 are indicated in dark gray. PCR-positive locations are indicated by red semicircles; upper, shower water or swab; lower, mixer tap water or swab. The 3 case-patients occupied cabins 18, 22, and 29. L. pneumophila was not isolated from any environmental samples. Legionella PCR result was positive in 7/10 cabins tested (13/27 samples) (Table 2). A PCR result was positive for showerheads or residual water from sink faucets in the cabins of 2 LD cases. In 5 other cabins, only faucets were positive (Figure 2). Detection of sludge or biofilm in the shower heads and faucets prompted replacement with better-designed showerheads and removal of faucet aerators. Only 2/79 samples collected on the second visit on September 4 were Legionella PCR positive; a significant reduction (χ2, Yates’ correction; 15.98, p<0.001). Only 1 of the 58 samples from the third series of samples was clearly PCR positive, from a faucet in a cabin unconnected to LD cases. The in-field PCR results were identical to the confirmatory reference laboratory replicate results. All 10 types of showerhead were rust-stained inside and smelled of chlorine. The most common showerhead types had either 7 silicone rubber O-rings or 1 complex silicone rubber gasket. Showerhead swabs and agar O-ring impressions grew profuse mixed bacteria, commonly Pseudomonas aeruginosa. Nonpneumophila Legionella sp. was isolated from 1 showerhead. Legionella PCR assays produced unambiguous positives in 13/16 showerheads (19/32 samples). Almost all O-rings from the common showerhead types were Legionella positive (Technical Appendix Part 2).
Table 2

Legionella pneumophila species PCR results from environmental samples collected on merchant vessel, Australia, 2015

Sample type
Samples collected on vessel, by date

Dismantled showerheads
August 27
September 4
October 12
Reference laboratory testing
Reference laboratory testing
In-field testing

Reference laboratory testing
Reference laboratory testing
Total
PCR+
Total
PCR+
Total
PCR+
Total
PCR+
Total
PCR+
Cabin shower heads633601202903219
Cabin faucets149331120291NANA
Air conditioning40NANANANANANANANA
Water supply20NANANANANANANANA
Others11101NANANANANANA
Total results
27
13

79
2

24
0

58
1

32
19
PCR controls
Positive, Legionella 
 DNA extract2222222222
Negative, ultrapure 
 water
6
0

16
0

5
0

12
0

6
0
*NA, not applicable; +, positive.
A recent study of nonpassenger merchant vessels (NPMVs) highlighted the risk for Legionella contamination of potable water systems (), but did not establish a link with confirmed infections. Our investigation of L. pneumophila serogroup 1 infection in a merchant vessel’s crew highlights the need to control Legionella in NPMV water systems, and the challenge of using PCR assays, which do not detect viable bacteria. Culture-dependent methods did not contribute to determination of the environmental source or route of dissemination. Preliminary control measures by external contractors may have prevented Legionella isolation from our environmental samples, but have doubtful long-term preventive value without sustained control measures because environmental persistence occurs in ships despite biocide treatment (). The survey vessel had a gross tonnage of 2,620, was 64 m long, 16 m wide, a draft of 4.7 m, and a crew of 27. It had 2 water storage tanks with 60,000 L capacity, an ultraviolet water sterilization unit, and 2 hot water geysers. These tanks were refilled from bunkers while in port, and replenished at sea by reverse osmosis. Showers were highlighted in a previous study of NPMV potable water systems (), and aerator devices have been implicated as bacterial amplification sites in tropical and nosocomial outbreaks (,). Multiple positive PCR results from water outlets in the cabins implicated the showers and faucets as means of infection. All showerheads on the vessel had interior moving parts to control spray settings and were the leading PCR-positive location. A rust-colored biofilm inside most showerheads indicated possible deterioration of iron pipes in the ship’s distribution system, and persistence of Legionella in biofilms (). The silicone rubber O-rings from the showerheads supported profuse growth of aquatic bacteria and were PCR positive for L. pneumophila. The O-rings formed a permanently wet niche for bacterial growth, and their movement will shear bacteria from biofilms. Faucet aerators also promote turbulent flow by mixing water and air under pressure. These results highlight the potential for Legionella aerosol generation. We recommended replacing the showerheads with a simpler plastic design, more suited to periodic removal, decontamination, and cleaning, and gravity drainage after daily use.

Conclusions

A cluster of L. pneumophila serogroup 1 infections in a vessel working in waters near Australia led to an environmental health assessment in which molecular methods enabled the field investigation team to implicate water outlets in crew quarters and tailor environmental controls. Deployment of quantitative PCR assays extended our investigative reach offshore, enabling faster return of the vessel to active service. The leadership and crew of nonpassenger merchant vessels operating in tropical waters need heightened Legionella awareness and require control measures more stringent than those applied in passenger vessels.

Technical Appendix

Detailed descriptions of environmental sample collection on the non-passenger merchant vessel at sea and in port, emergency control measures, and detailed results of PCR and culture to identify pathogens.
  13 in total

1.  Emergence of multi-resistant Pseudomonas aeruginosa in a Western Australian hospital.

Authors:  T J J Inglis; K A Benson; L O'Reilly; R Bradbury; M Hodge; D Speers; C H Heath
Journal:  J Hosp Infect       Date:  2010-05-06       Impact factor: 3.926

2.  Cruise-ship--associated Legionnaires disease, November 2003-May 2004.

Authors: 
Journal:  MMWR Morb Mortal Wkly Rep       Date:  2005-11-18       Impact factor: 17.586

3.  Water Safety Plan on cruise ships: a promising tool to prevent waterborne diseases.

Authors:  Varvara A Mouchtouri; Christopher L R Bartlett; Arthur Diskin; Christos Hadjichristodoulou
Journal:  Sci Total Environ       Date:  2012-05-17       Impact factor: 7.963

4.  Growth of Legionella anisa in a model drinking water system to evaluate different shower outlets and the impact of cast iron rust.

Authors:  Wilco van der Lugt; Sjoerd M Euser; Jacob P Bruin; Jeroen W Den Boer; Jimmy T Walker; Sebastian Crespi
Journal:  Int J Hyg Environ Health       Date:  2017-08-18       Impact factor: 5.840

Review 5.  Legionnaires' Disease in Hotels and Passenger Ships: A Systematic Review of Evidence, Sources, and Contributing Factors.

Authors:  Varvara A Mouchtouri; James W Rudge
Journal:  J Travel Med       Date:  2015-07-29       Impact factor: 8.490

6.  Persistence of chlorine-sensitive Legionella pneumophila in hyperchlorinated installations.

Authors:  M T García; B Baladrón; V Gil; M L Tarancon; A Vilasau; A Ibañez; C Elola; C Pelaz
Journal:  J Appl Microbiol       Date:  2008-06-14       Impact factor: 3.772

7.  High prevalence of Legionella in non-passenger merchant vessels.

Authors:  S L Collins; D Stevenson; M Mentasti; A Shaw; A Johnson; L Crossley; C Willis
Journal:  Epidemiol Infect       Date:  2016-11-28       Impact factor: 4.434

8.  Prevalence study of Legionella spp. contamination in ferries and cruise ships.

Authors:  Antonio Azara; Andrea Piana; Giovanni Sotgiu; Marco Dettori; Maria Grazia Deriu; Maria Dolores Masia; Bianca Maria Are; Elena Muresu
Journal:  BMC Public Health       Date:  2006-04-18       Impact factor: 3.295

9.  Legionella species colonization of water distribution systems, pools and air conditioning systems in cruise ships and ferries.

Authors:  Georgia Goutziana; Varvara A Mouchtouri; Maria Karanika; Antonios Kavagias; Nikolaos E Stathakis; Kostantinos Gourgoulianis; Jenny Kremastinou; Christos Hadjichristodoulou
Journal:  BMC Public Health       Date:  2008-11-24       Impact factor: 3.295

10.  A single Legionella pneumophila genotype in the freshwater system in a ship experiencing three separate outbreaks of legionellosis in 6 years.

Authors:  Catrine Ahlen; Marianne Aas; Jadwiga Krusnell; Ole-Jan Iversen
Journal:  Microb Ecol Health Dis       Date:  2016-08-10
View more
  2 in total

1.  Epidemiologic Survey of Legionella Urine Antigen Testing Within a Large Wisconsin-Based Health Care System.

Authors:  Caroline P Toberna; Hannah M William; Jessica J F Kram; Kayla Heslin; Dennis J Baumgardner
Journal:  J Patient Cent Res Rev       Date:  2020-04-27

Review 2.  Persistence of Pathogens on Inanimate Surfaces: A Narrative Review.

Authors:  Jan Erik Wißmann; Lisa Kirchhoff; Yannick Brüggemann; Daniel Todt; Joerg Steinmann; Eike Steinmann
Journal:  Microorganisms       Date:  2021-02-09
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.