| Literature DB >> 29912714 |
Timothy J J Inglis, Chantal Spittle, Hilary Carmichael, Jaala Downes, Marilina Chiari, Adrian McQueen-Mason, Adam J Merritt, Meredith Hodge, Ronan J Murray, Gary K Dowse.
Abstract
Two cases of Legionnaires' disease and 1 of Pontiac fever occurred among the crew of a merchant ship operating off the shores of Australia. PCR assays identified potential sources in the ship's cabins. Modification of maritime regulations for Legionnaires' disease prevention in commercial vessels is needed for nonpassenger merchant ships.Entities:
Keywords: Australia; Indian Ocean; Legionella pneumophila; Legionnaires’ disease; PCR; Pontiac fever; bacteria; biofilm; cruise; deployable microbiology; environmental control; fomite; health threat assessment; merchant ship; occupational risk; outbreak investigation; pneumonia; pneumothorax; reservoir; respiratory; vessel
Mesh:
Year: 2018 PMID: 29912714 PMCID: PMC6038751 DOI: 10.3201/eid2407.171978
Source DB: PubMed Journal: Emerg Infect Dis ISSN: 1080-6040 Impact factor: 6.883
Figure 1Dismantled showerhead from nonpassenger merchant vessel showing multiple inner parts, including 7 O-rings, all of which were in contact with water passing through shower, Australia, 2015.
Summary of confirmed legionellosis cases and results of environmental PCR testing in the case-patients’ merchant vessel cabins, August 2015*
| Case-patient | Age, y | Onset | Infection | Hospital | UAT | Serology | PCR† | Cabin no. | Cabin samples (Aug 27) | ||
| Shower water | Shower-head swab | Bathroom sink faucet | |||||||||
| 1 | 54 | Aug 12 | Lower respiratory | Regional | + | _ | + | 22 | + | _ | + |
| 2 | 55 | Aug 19 | Lower respiratory | Tertiary | + | _ | + | 18 | + | + | + |
| 3 | 48 | Aug 10 | Mild respiratory | Not required | _ | Conversion (0–2,048) | _ | 29 | NA‡ | NA‡ | NA‡ |
*NA, not available; UAT, urinary antigen test; +, positive; –-, negative. †PCR-positive Legionella pneumophila. ‡Cabin in use on August 27, 2015. Water from hand basin faucet collected on August 20 by private agency was culture negative.
Figure 2Accommodation deck plan, Australia, 2015. Cabins (n = 10) and other rooms (ACU, air conditioning unit) from which environmental samples were collected on August 27, 2015 are indicated in dark gray. PCR-positive locations are indicated by red semicircles; upper, shower water or swab; lower, mixer tap water or swab. The 3 case-patients occupied cabins 18, 22, and 29.
Legionella pneumophila species PCR results from environmental samples collected on merchant vessel, Australia, 2015
| Sample type | Samples collected on vessel, by date |
| Dismantled showerheads | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| August 27 |
| September 4 |
| October 12 | ||||||||||
| Reference laboratory testing | Reference laboratory testing | In-field testing |
| Reference laboratory testing | Reference laboratory testing | |||||||||
| Total | PCR+ | Total | PCR+ | Total | PCR+ | Total | PCR+ | Total | PCR+ | |||||
| Cabin shower heads | 6 | 3 | 36 | 0 | 12 | 0 | 29 | 0 | 32 | 19 | ||||
| Cabin faucets | 14 | 9 | 33 | 1 | 12 | 0 | 29 | 1 | NA | NA | ||||
| Air conditioning | 4 | 0 | NA | NA | NA | NA | NA | NA | NA | NA | ||||
| Water supply | 2 | 0 | NA | NA | NA | NA | NA | NA | NA | NA | ||||
| Others | 1 | 1 | 10 | 1 | NA | NA | NA | NA | NA | NA | ||||
| Total results | 27 | 13 |
| 79 | 2 |
| 24 | 0 |
| 58 | 1 |
| 32 | 19 |
| PCR controls | ||||||||||||||
| Positive, | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | ||||
| Negative, ultrapure
water | 6 | 0 |
| 16 | 0 |
| 5 | 0 |
| 12 | 0 |
| 6 | 0 |
| *NA, not applicable; +, positive. | ||||||||||||||