Literature DB >> 29907516

Repeatability of tibial acceleration measurements made on children during walking and running.

Oren Tirosh1, Guy Orland2, Alon Eliakim3, Dan Nemet3, Nili Steinberg2.   

Abstract

OBJECTIVES: To determine the between-visit reliability of an accelerometer as a measure of lower-extremity impact acceleration at a variety of gait speeds in children.
DESIGN: Absolute reliability assessment.
METHODS: Ten children with no known gait pathology attended two testing sessions, three weeks apart. A tri-axial accelerometer was fixed to the child's distal tibia to measure peak positive acceleration responses while walking and running on the treadmill at three different speeds (comfortable walking, threshold walking, and jogging). Reliability of the average and standard deviation Peak Positive Acceleration (avgPPA and sdPPA, respectively) was calculated by intra-class correlation coefficients (ICC) and Minimum Detectable Change (MDC).
RESULTS: Excellent reliability was indicated with ICC values for avgPPA of 0.90, 0.95, and 0.81 for comfortable walking, threshold walking, and jogging, respectively. Moderate reliability was found for the sdPPA measures. MDC values were calculated to be 18%, 26%, and 23% for comfortable walking, threshold walking, and jogging, respectively, indicating the amount by which an avgPPA value would need to change to ensure that the change is greater than a measurement error.
CONCLUSIONS: An accelerometer attached to the distal tibia is practical for use in a clinical environment to collect lower extremity acceleration data in children. Clinicians can utilise this technique for assessing a change following an intervention, such as biofeedback gait retraining.
Copyright © 2018 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Gait; Ground impact acceleration; Tibial accelerometer

Mesh:

Year:  2018        PMID: 29907516     DOI: 10.1016/j.jsams.2018.04.006

Source DB:  PubMed          Journal:  J Sci Med Sport        ISSN: 1878-1861            Impact factor:   4.319


  2 in total

1.  Criterion Validity of Linear Accelerations Measured with Low-Sampling-Frequency Accelerometers during Overground Walking in Elderly Patients with Knee Osteoarthritis.

Authors:  Arash Ghaffari; Ole Rahbek; Rikke Emilie Kildahl Lauritsen; Andreas Kappel; Søren Kold; John Rasmussen
Journal:  Sensors (Basel)       Date:  2022-07-15       Impact factor: 3.847

Review 2.  Is This the Real Life, or Is This Just Laboratory? A Scoping Review of IMU-Based Running Gait Analysis.

Authors:  Lauren C Benson; Anu M Räisänen; Christian A Clermont; Reed Ferber
Journal:  Sensors (Basel)       Date:  2022-02-23       Impact factor: 3.576

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.