Literature DB >> 29901674

Aptamer immobilization on amino-functionalized metal-organic frameworks: an ultrasensitive platform for the electrochemical diagnostic of Escherichia coli O157:H7.

Saeed Shahrokhian1, Saba Ranjbar2.   

Abstract

Herein, we report the development of an electrochemical biosensor for Escherichia coli O157:H7 diagnostic based on amino-functionalized metal-organic frameworks (MOFs) as a new generation of organic-inorganic hybrid nanocomposites. The electrical and morphological properties of MOFs were enhanced by interweaving each isolated MOF crystal with polyaniline (PANI). Subsequent attachment of the amine-modified aptamer to the polyanilinated MOFs was accomplished using glutaraldehyde (GA) as a cross-linking agent. The prepared biocompatible platform was carefully characterized by means of field-emission scanning electron microscopy (FESEM), energy-dispersive spectroscopy (EDS), Fourier transform infrared spectroscopy (FT-IR), and X-ray powder diffraction (XRD) techniques. The biosensor fabrication and its electrochemical characterizations were monitored by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) techniques. Differential pulse voltammetry (DPV) was applied to monitoring and quantitation of the interaction between the aptamer and E. coli O157:H7 using methylene blue (MB) as an electrochemical indicator. Changes in the reduction peak current of MB in the presence of E. coli O157:H7 was recorded as an analytical signal and indicated a relationship with the logarithm of the E. coli O157:H7 concentration in the range of 2.1 × 101 to 2.1 × 107 CFU mL-1 with a LOQ of 21 CFU mL-1 and LOD of 2 CFU mL-1. The electrochemical aptasensor displayed good recovery values for the detection of E. coli O157:H7 in environmental real samples and also could act as a smart device to investigate the effects of antibacterial agents against E. coli O157:H7.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 29901674     DOI: 10.1039/c8an00725j

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  12 in total

1.  Point-of-care detection of Escherichia coli O157:H7 in water using AuNPs-based aptasensor.

Authors:  Vahid Soheili; Seyed Mohammad Taghdisi; Khalil Abnous; Mohsen Ebrahimi
Journal:  Iran J Basic Med Sci       Date:  2020-07       Impact factor: 2.699

2.  Single cell immunodetection of Escherichia coli O157:H7 on an indium-tin-oxide electrode by using an electrochemical label with an organic-inorganic nanostructure.

Authors:  Dung Quang Nguyen; Kengo Ishiki; Hiroshi Shiigi
Journal:  Mikrochim Acta       Date:  2018-09-17       Impact factor: 5.833

Review 3.  Aptamer-functionalized metal-organic frameworks (MOFs) for biosensing.

Authors:  Mengzhen Lv; Wan Zhou; Hamed Tavakoli; Cynthia Bautista; Jianfei Xia; Zonghua Wang; XiuJun Li
Journal:  Biosens Bioelectron       Date:  2020-12-30       Impact factor: 10.618

4.  On-site detection of food and waterborne bacteria - current technologies, challenges, and future directions.

Authors:  Sabrina Petrucci; Connor Costa; David Broyles; Emre Dikici; Sylvia Daunert; Sapna Deo
Journal:  Trends Food Sci Technol       Date:  2021-06-29       Impact factor: 16.002

Review 5.  Electrochemical Aptasensors Based on Hybrid Metal-Organic Frameworks.

Authors:  Gennady Evtugyn; Svetlana Belyakova; Anna Porfireva; Tibor Hianik
Journal:  Sensors (Basel)       Date:  2020-12-05       Impact factor: 3.576

Review 6.  Recent Progress in the Identification of Aptamers Against Bacterial Origins and Their Diagnostic Applications.

Authors:  Nevina E Trunzo; Ka Lok Hong
Journal:  Int J Mol Sci       Date:  2020-07-18       Impact factor: 5.923

Review 7.  Pathogen detection with electrochemical biosensors: Advantages, challenges and future perspectives.

Authors:  Hüseyin Oğuzhan Kaya; Arif E Cetin; Mostafa Azimzadeh; Seda Nur Topkaya
Journal:  J Electroanal Chem (Lausanne)       Date:  2021-01-09       Impact factor: 4.464

Review 8.  Selection and applications of functional nucleic acids for infectious disease detection and prevention.

Authors:  Lin Zhu; Jiajun Ling; Zhi Zhu; Tian Tian; Yanling Song; Chaoyong Yang
Journal:  Anal Bioanal Chem       Date:  2021-01-28       Impact factor: 4.478

9.  Highly Sensitive and Cost-Effective Portable Sensor for Early Gastric Carcinoma Diagnosis.

Authors:  Saw-Lin Oo; Shishir Venkatesh; Vaithinathan Karthikeyan; Clement Manohar Arava; Spoorthy Pathikonda; Peter K N Yu; Terrence C K Lau; Xianfeng Chen; Vellaisamy A L Roy
Journal:  Sensors (Basel)       Date:  2021-04-09       Impact factor: 3.576

Review 10.  Aptamer-Based Biosensors for Environmental Monitoring.

Authors:  Erin M McConnell; Julie Nguyen; Yingfu Li
Journal:  Front Chem       Date:  2020-05-29       Impact factor: 5.221

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.