Literature DB >> 29901441

Optical coherence tomography substudy of a prospective multicentre randomised post-market trial to assess the safety and effectiveness of the Firehawk cobalt-chromium coronary stent (rapamycin target-eluting) system for the treatment of atherosclerotic lesions: TARGET All Comers.

Andreas Baumbach1, Alexandra J Lansky, Yoshinobu Onuma, Taku Asano, Thomas Johnson, Richard Anderson, Ferdinand Kiemeneij, Ming Zheng, Niels Van Royen, Ton Slagboom, Georg Vlachojannis, Bo Xu, Patrick W Serruys, William Wijns.   

Abstract

AIMS: Durable polymer drug-eluting stents (DP-DES) may contribute to persistent inflammation, delayed endothelial healing and subsequent late DES thrombosis. The aim of this optical coherence tomography (OCT) substudy was to compare healing and neointimal coverage of a novel bioabsorbable polymer sirolimus-eluting stent (Firehawk®) (BP-DES) versus the DP-DES (XIENCE) at 90 days in an all-comers patient population. METHODS AND
RESULTS: The TARGET All Comers study is a prospective multicentre randomised post-market trial of 1,656 patients randomised 1:1 to Firehawk or XIENCE at 21 centres in 10 European countries. The TARGET OCT substudy enrolled 36 consecutive patients with 52 lesions at six centres proficient in OCT. Follow-up OCT was performed at three months or prior to revascularisation when occurring before the three-month window. The substudy was designed for non-inferiority of the primary endpoint of neointimal thickness. At follow-up, the mean neointimal thickness by OCT (52 lesions: Firehawk, n=24; XIENCE, n=28), was not significantly different between groups (Firehawk 75.5 μm vs. XIENCE V 82.3 μm) meeting the primary endpoint of non-inferiority (pnoninferiority<0.001). The percentage of stent strut coverage was high in both groups (strut level: 99.9±0.3% vs. 100±0.1%, p=0.26), and the proportion of malapposed struts (1.0±1.6% vs. 1.2±2.0%, p=0.51) was low in both groups.
CONCLUSIONS: Based on OCT, the Firehawk BP-DES has a similar healing response three months after implantation compared to the DP-DES, with near complete strut coverage, moderate neointima formation and minimal strut malapposition.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 29901441     DOI: 10.4244/EIJ-D-18-00226

Source DB:  PubMed          Journal:  EuroIntervention        ISSN: 1774-024X            Impact factor:   6.534


  3 in total

1.  A Randomized Comparison of the Healing Response Between the Firehawk Stent and the Xience Stent in Patients With ST-Segment Elevation Myocardial Infarction at 6 Months of Follow-Up (TARGET STEMI OCT China Trial): An Optical Coherence Tomography Study.

Authors:  Yuan He; Rutao Wang; Jianzheng Liu; Fei Li; Jiayi Li; Chengxiang Li; Jingyu Zhou; Zhijing Zhao; Wangwei Yang; Fangjun Mou; Jing Wang; Jing Kan; Xiaobo Li; Yan Li; Ming Zheng; Shaoliang Chen; Chao Gao; Ling Tao
Journal:  Front Cardiovasc Med       Date:  2022-06-01

2.  Prospective multicentre open-label randomised controlled trial of 3-month versus 12-month dual antiplatelet therapy after implantation of the new generation biodegradable polymer sirolimus TARGET-eluting coronary stent: protocol of the TARGET DAPT trial.

Authors:  Hongbo Yang; Feng Zhang; Ji'e Yang; Ming Zheng; Ruifen Cao; Yuxiang Dai; Chenguang Li; Kang Yao; Juying Qian; Junbo Ge
Journal:  BMJ Open       Date:  2019-12-17       Impact factor: 2.692

3.  Comparison of neointimal coverage between ultrathin biodegradable polymer-coated sirolimus-eluting stents and durable polymer-coated everolimus-eluting stents: 6 months optical coherence tomography follow-up from the TAXCO study.

Authors:  Atul Abhyankar; Alexandre Abizaid; Daniel Chamié; Mihir Rathod
Journal:  Catheter Cardiovasc Interv       Date:  2020-04-03       Impact factor: 2.692

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.