| Literature DB >> 29899176 |
Manabu Nemoto1, Takashi Yamanaka1, Hiroshi Bannai1, Koji Tsujimura1, Takanori Ueno1, Hirohisa Mekata2, Ayako Yoshida2, Aki Koyama3, Hiroshi Kokado1.
Abstract
This study compared agar gel immunodiffusion (AGID) protocols for diagnosing equine infectious anemia. Two commercial testing kits were used: one following the Japanese Act on Domestic Animal Infectious Diseases Control and one following the World Organisation for Animal Health (OIE) manual. From 651 samples tested, both protocols gave identical results for 647 samples (23 samples tested positive; 624 tested negative). Non-specific reactions were observed in 21 samples testing negative by the Japanese protocol, but none were observed with the OIE protocol. The kappa coefficient value was 0.962, indicating almost perfect agreement between the two protocols. This study found no difference in diagnostic agreement between the two protocols, but the OIE protocol produced non-specific reactions less frequently than the Japanese protocol.Entities:
Keywords: Japanese act; OIE; agar gel immunodiffusion; equine infectious anemia
Mesh:
Substances:
Year: 2018 PMID: 29899176 PMCID: PMC6115256 DOI: 10.1292/jvms.18-0103
Source DB: PubMed Journal: J Vet Med Sci ISSN: 0916-7250 Impact factor: 1.267
Comparison of results of two agar gel immunodiffusion protocols for diagnosis of equine infectious anemia according to the Japanese act and according to the OIE manual using 651 serum samples
| Japanese protocol | Total | ||||
|---|---|---|---|---|---|
| + | − | ? | |||
| OIE protocol | + | 23 | 0 | 1 | 24 |
| − | 0 | 624 | 0 | 624 | |
| ? | 1 | 0 | 2 | 3 | |
| Total | 24 | 624 | 3 | 651 | |
+: positive, −: negative, ?: inconclusive.
Fig. 1.Results of agar gel immunodiffusion test in accordance with Japanese (A) and OIE (B) protocols. All four samples were diagnosed as negative for equine infectious anemia. Non-specific reactions were produced (A) or were not produced (B) in 1–4 samples. 1–4: Individual horse serum samples, AG: Antigen, PS: Positive serum sample.