Impact of dose engine algorithm in pencil beam scanning proton therapy for breast cancer.

Francesco Tommasino1, Francesco Fellin2, Stefano Lorentini2, Paolo Farace2.   

Abstract

PURPOSE: Proton therapy for the treatment of breast cancer is acquiring increasing interest, due to the potential reduction of radiation-induced side effects such as cardiac and pulmonary toxicity. While several in silico studies demonstrated the gain in plan quality offered by pencil beam scanning (PBS) compared to passive scattering techniques, the related dosimetric uncertainties have been poorly investigated so far.
METHODS: Five breast cancer patients were planned with Raystation 6 analytical pencil beam (APB) and Monte Carlo (MC) dose calculation algorithms. Plans were optimized with APB and then MC was used to recalculate dose distribution. Movable snout and beam splitting techniques (i.e. using two sub-fields for the same beam entrance, one with and the other without the use of a range shifter) were considered. PTV dose statistics were recorded. The same planning configurations were adopted for the experimental benchmark. Dose distributions were measured with a 2D array of ionization chambers and compared to APB and MC calculated ones by means of a γ analysis (agreement criteria 3%, 3 mm).
RESULTS: Our results indicate that, when using proton PBS for breast cancer treatment, the Raystation 6 APB algorithm does not allow obtaining sufficient accuracy, especially with large air gaps. On the contrary, the MC algorithm resulted into much higher accuracy in all beam configurations tested and has to be recommended.
CONCLUSIONS: Centers where a MC algorithm is not yet available should consider a careful use of APB, possibly combined with a movable snout system or in any case with strategies aimed at minimizing air gaps.
Copyright © 2018 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Breast cancer; Monte carlo; Pencil beam scanning; Proton therapy

Mesh:

Year:  2018        PMID: 29891097     DOI: 10.1016/j.ejmp.2018.05.018

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  3 in total

1.  Pitfalls in the beam modelling process of Monte Carlo calculations for proton pencil beam scanning.

Authors:  Carla Winterhalter; Adam Aitkenhead; David Oxley; Jenny Richardson; Damien C Weber; Ranald I MacKay; Antony J Lomax; Sairos Safai
Journal:  Br J Radiol       Date:  2020-02-06       Impact factor: 3.039

2.  Is an analytical dose engine sufficient for intensity modulated proton therapy in lung cancer?

Authors:  Suliana Teoh; Francesca Fiorini; Ben George; Katherine A Vallis; Frank Van den Heuvel
Journal:  Br J Radiol       Date:  2019-11-20       Impact factor: 3.629

3.  Comparative photon and proton dosimetry for patients with mediastinal lymphoma in the era of Monte Carlo treatment planning and variable relative biological effectiveness.

Authors:  Yolanda D Tseng; Shadonna M Maes; Gregory Kicska; Patricia Sponsellor; Erik Traneus; Tony Wong; Robert D Stewart; Jatinder Saini
Journal:  Radiat Oncol       Date:  2019-12-30       Impact factor: 3.481

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.