Literature DB >> 29890910

3rd generation ceramic-on-ceramic cementless total hip arthroplasty: a minimum 10-year follow-up study.

Yeong J Lau1, Shashank Sarmah1, Johan D Witt1.   

Abstract

INTRODUCTION: 3rd generation ceramic bearings were introduced in total hip arthroplasty (THA) with the potential to have better mechanical strength and wear properties than their predecessors. At present, there are few studies looking at the long-term results of this latest generation of ceramic bearings. The purpose of our study was to investigate the long-term clinical and radiographic results of 3rd generation ceramic-on-ceramic THA and the incidence of ceramic specific complications such as squeaking and bearing surface fracture.
METHODS: The database of the senior author (J.D.W.) was reviewed. A total of 126 hip replacements performed in 108 patients (average age 39.6 years) with an average follow-up of 12.1 years (10-16 years) was identified. Clinical notes and plain radiographs were reviewed. To measure function, patients were contacted and an Oxford Hip Questionnaire was completed. Patients were also directly questioned about the presence of squeaking or any other sounds from the hip. Radiographs were evaluated for signs of wear, osteolysis, loosening and heterotopic ossification. The abduction angle of the acetabular component was measured.
RESULTS: The average Oxford Hip Score was 39.8 out of 48. Survivorship at 10 years was 94.6% (95% CI) with revision for any cause as the endpoint. There was 1 femoral head fracture, no osteolysis, no squeaking and no detectable wear.
CONCLUSIONS: The good clinical and radiographic results for this series of patients are similar to other recent long-term studies looking at 3rd generation ceramic-on-ceramic THA. The results compare favourably with other bearing surfaces. The lack of osteolysis associated with this articulation is encouraging and may also make it a good choice for younger patients requiring total hip replacement.

Entities:  

Keywords:  Arthroplasty; Ceramics; Hip; Replacement

Mesh:

Year:  2018        PMID: 29890910     DOI: 10.1177/1120700018768617

Source DB:  PubMed          Journal:  Hip Int        ISSN: 1120-7000            Impact factor:   2.135


  2 in total

1.  Effect of continuous nursing combined with salcatonin on postoperative pains in elderly patients after hip replacement.

Authors:  Liyu Zhu; Lin Li; Binyan Yin; Xian Jiang; Huanchuan Peng; Xiaomin Hou
Journal:  Am J Transl Res       Date:  2021-05-15       Impact factor: 4.060

Review 2.  Ten-year survival of ceramic-on-ceramic total hip arthroplasty in patients younger than 60 years: a systematic review and meta-analysis.

Authors:  Ihab Ibraheam El-Desouky; Albaraa Hassan Helal; Ali Mohamed Reda Mansour
Journal:  J Orthop Surg Res       Date:  2021-11-18       Impact factor: 2.359

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.