Literature DB >> 29878999

Optimizing Perforator Selection: A Multivariable Analysis of Predictors for Fat Necrosis and Abdominal Morbidity in DIEP Flap Breast Reconstruction.

Austin Hembd1, Sumeet S Teotia, Hong Zhu, Nicholas T Haddock.   

Abstract

BACKGROUND: This study aims to elucidate the important predicting factors for fat necrosis and abdominal morbidity in the patient undergoing deep inferior epigastric artery perforator flap reconstruction.
METHODS: The authors conducted a retrospective review of 866 free-flap breast reconstructions performed at one institution from 2010 to 2016. Twenty-eight potential predictors were included in multivariable analyses to control for possible confounding interactions.
RESULTS: Four hundred nine total deep inferior epigastric artery perforator flaps were included in the statistical analysis. Of these, 14.4 percent had flap fat necrosis, 21.3 percent had an abdominal wound or complication, and 6 percent had an abdominal bulge or hernia. Analysis showed an increase in the odds of fat necrosis with increasing flap weight (OR, 1.002 per 1-g increase; p = 0.0002). A decrease in the odds of fat necrosis was seen with lateral row (OR, 0.29; p = 0.001) and both medial and lateral row perforator flaps (OR, 0.21; p = 0.001), if indocyanine green angiography was used (OR, 0.46; p = 0.04), and with increasing total flow rate of the flap (OR, 0.62 per 1-mm/second increase; p = 0.05). Increased odds of abdominal bulge or hernia were seen with lateral row or both medial and lateral row perforators (OR, 3.21; p = 0.05) versus medial row perforator-based flaps, and with patients who had an abdominal wound postoperatively (OR, 2.59; p = 0.05).
CONCLUSIONS: The authors' results suggest that using larger caliber perforators and perforators from the lateral row alone, or in addition to medial row perforators, can decrease fat necrosis more than simply harvesting more perforators alone. However, lateral and both medial and lateral row perforator flaps come at the cost of increasing abdominal bulge rates. CLINICAL QUESTION/LEVEL OF EVIDENCE: Risk, III.

Entities:  

Mesh:

Year:  2018        PMID: 29878999     DOI: 10.1097/PRS.0000000000004631

Source DB:  PubMed          Journal:  Plast Reconstr Surg        ISSN: 0032-1052            Impact factor:   4.730


  3 in total

1.  [Multivariable analysis for flap-related complications in autologous breast reconstruction and economic analysis of intraoperative indocyanine green angiography].

Authors:  Zeyang Liu; Zan Li; Xiaowei Peng; Bo Zhou; Yuanyuan Tang; Peng Wu; Dajiang Song; Chunliu Lü; Wen Peng; Hui Li; Yan Ou; Anji Xu
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2020-01-15

2.  Efficient DIEP Flap: Bilateral Breast Reconstruction in Less Than Four Hours.

Authors:  Nicholas T Haddock; Sumeet S Teotia
Journal:  Plast Reconstr Surg Glob Open       Date:  2021-09-07

3.  Indocyanine Green Angiography in Breast Reconstruction: Utility, Limitations, and Search for Standardization.

Authors:  Ariel C Johnson; Salih Colakoglu; Tae W Chong; David W Mathes
Journal:  Plast Reconstr Surg Glob Open       Date:  2020-03-27
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.