Literature DB >> 29877827

A Wearable Detector for Simultaneous Finger Joint Motion Measurement.

Xiaodong Li, Rongwei Wen, Zhong Shen, Zheng Wang, Keith Dip Kei Luk, Yong Hu.   

Abstract

This paper presents a wearable and stretchable detector for simultaneous finger joint motion measurement, providing the feasible technical solutions to solve the problems existing in the current devices. The sensor array installed in the detector consists of 14 custom-made bending sensors and an inertial measurement unit with high accuracy. The glove support for a sensor array, which is made of three silicone materials with different elasticity, not only overcomes the drawbacks of cloth support, but also addresses the compatibility between the stretch substrate and the inelastic sensing components. Besides, two-section electrical connection avoids the problems caused by the external wires in traditional solutions to enhance the durability of glove. The experiment results indicated that the wearable detector offers a good user experience by exerting a small force on fingers. The device also shows a strong durability as it worked properly after tens of thousands of bending. The measurement tests on a single sensor demonstrated that two kinds of sensors are both with high accuracy. Besides, the hand goniometric system has an excellent performance in terms of hand motion detection. The measurement error of the device in subjects with different hand sizes is within a reasonable range. The good properties of the sensory detector allow it to be applied in clinical applications.

Entities:  

Mesh:

Year:  2018        PMID: 29877827     DOI: 10.1109/TBCAS.2018.2810182

Source DB:  PubMed          Journal:  IEEE Trans Biomed Circuits Syst        ISSN: 1932-4545            Impact factor:   3.833


  5 in total

1.  Development and Operation of an Experimental System to Measure the Moments Generated in the Finger Joints.

Authors:  Gregory Chagnon; Khouloud Achouri; Nathanael Connesson; Julien Gerbelot; Aurelien Courvoisier
Journal:  Bioengineering (Basel)       Date:  2022-04-22

2.  The use of three-dimensional model construction of virtual technology in orthopedic treatment.

Authors:  Chenguang Li; Feng Xue; Fengxin Zhou
Journal:  Saudi J Biol Sci       Date:  2020-03-10       Impact factor: 4.219

3.  Clip-On IMU System for Assessing Age-Related Changes in Hand Functions.

Authors:  Seungjae Lee; Hyejeong Lee; Jongshill Lee; Hokyoung Ryu; In Young Kim; Jieun Kim
Journal:  Sensors (Basel)       Date:  2020-11-05       Impact factor: 3.576

4.  3D-Printed Soft Pneumatic Robotic Digit Based on Parametric Kinematic Model for Finger Action Mimicking.

Authors:  Shumi Zhao; Ziwen Wang; Yisong Lei; Jie Zhang; Yuyao Li; Zeji Sun; Zidan Gong
Journal:  Polymers (Basel)       Date:  2022-07-07       Impact factor: 4.967

5.  Wearable Hand Module and Real-Time Tracking Algorithms for Measuring Finger Joint Angles of Different Hand Sizes with High Accuracy using FBG Strain Sensor.

Authors:  Jun Sik Kim; Byung Kook Kim; Minsu Jang; Kyumin Kang; Dae Eun Kim; Byeong-Kwon Ju; Jinseok Kim
Journal:  Sensors (Basel)       Date:  2020-03-30       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.