Literature DB >> 29873299

Carbon ions beam therapy monitoring with the INSIDE in-beam PET.

Francesco Pennazio1, Giuseppe Battistoni, Maria Giuseppina Bisogni, Niccolò Camarlinghi, Alfredo Ferrari, Veronica Ferrero, Elisa Fiorina, Matteo Morrocchi, Paola Sala, Giancarlo Sportelli, Richard Wheadon, Piergiorgio Cerello.   

Abstract

In vivo range monitoring techniques are necessary in order to fully take advantage of the high dose gradients deliverable in hadrontherapy treatments. Positron emission tomography (PET) scanners can be used to monitor beam-induced activation in tissues and hence measure the range. The INSIDE (Innovative Solutions for In-beam DosimEtry in Hadrontherapy) in-beam PET scanner, installed at the Italian National Center of Oncological Hadrontherapy (CNAO, Pavia, Italy) synchrotron facility, has already been successfully tested in vivo during a proton therapy treatment. We discuss here the system performance evaluation with carbon ion beams, in view of future in vivo tests. The work is focused on the analysis of activity images obtained with therapeutic treatments delivered to polymethyl methacrylate (PMMA) phantoms, as well as on the test of an innovative and robust Monte Carlo simulation technique for the production of reliable prior activity maps. Images are reconstructed using different integration intervals, so as to monitor the activity evolution during and after the treatment. Three procedures to compare activity images are presented, namely Pearson correlation coefficient, Beam's eye view and overall view. Images of repeated irradiations of the same treatments are compared to assess the integration time necessary to provide reproducible images. The range agreement between simulated and experimental images is also evaluated, so as to validate the simulation capability to provide sound prior information. The results indicate that at treatment end, or at most 20 s afterwards, the range measurement is reliable within 1-2 mm, when comparing both different experimental sessions and data with simulations. In conclusion, this work shows that the INSIDE in-beam PET scanner performance is promising towards its in vivo test with carbon ions.

Entities:  

Mesh:

Year:  2018        PMID: 29873299     DOI: 10.1088/1361-6560/aacab8

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  7 in total

1.  Ultrasound-assisted carbon ion dosimetry and range measurement using injectable polymer-shelled phase-change nanodroplets: in vitro study.

Authors:  Yosra Toumia; Marco Pullia; Fabio Domenici; Angelica Facoetti; Michele Ferrarini; Sophie V Heymans; Bram Carlier; Koen Van Den Abeele; Edmond Sterpin; Jan D'hooge; Emiliano D'Agostino; Gaio Paradossi
Journal:  Sci Rep       Date:  2022-05-14       Impact factor: 4.996

Review 2.  Biological Rationale and Clinical Evidence of Carbon Ion Radiation Therapy for Adenoid Cystic Carcinoma: A Narrative Review.

Authors:  Pierre Loap; Barbara Vischioni; Maria Bonora; Rossana Ingargiola; Sara Ronchi; Viviana Vitolo; Amelia Barcellini; Lucia Goanta; Ludovic De Marzi; Remi Dendale; Roberto Pacelli; Laura Locati; Valentin Calugaru; Hamid Mammar; Stefano Cavalieri; Youlia Kirova; Ester Orlandi
Journal:  Front Oncol       Date:  2021-11-30       Impact factor: 6.244

3.  Nuclear Fragmentation Imaging for Carbon-Ion Radiation Therapy Monitoring: an In Silico Study.

Authors:  Anissa Bey; Jiasen Ma; Keith M Furutani; Michael G Herman; Jedediah E Johnson; Robert L Foote; Chris J Beltran
Journal:  Int J Part Ther       Date:  2021-09-01

4.  Localization of anatomical changes in patients during proton therapy with in-beam PET monitoring: A voxel-based morphometry approach exploiting Monte Carlo simulations.

Authors:  Aafke Christine Kraan; Andrea Berti; Alessandra Retico; Guido Baroni; Giuseppe Battistoni; Nicola Belcari; Piergiorgio Cerello; Mario Ciocca; Micol De Simoni; Damiano Del Sarto; Marco Donetti; Yunsheng Dong; Alessia Embriaco; Veronica Ferrero; Elisa Fiorina; Marta Fischetti; Gaia Franciosini; Giuseppe Giraudo; Francesco Laruina; Davide Maestri; Marco Magi; Giuseppe Magro; Carlo Mancini Terracciano; Michela Marafini; Ilaria Mattei; Enrico Mazzoni; Paolo Mereu; Riccardo Mirabelli; Alfredo Mirandola; Matteo Morrocchi; Silvia Muraro; Alessandra Patera; Vincenzo Patera; Francesco Pennazio; Angelo Rivetti; Manuel Dionisio Da Rocha Rolo; Valeria Rosso; Alessio Sarti; Angelo Schiavi; Adalberto Sciubba; Elena Solfaroli Camillocci; Giancarlo Sportelli; Sara Tampellini; Marco Toppi; Giacomo Traini; Serena Marta Valle; Francesca Valvo; Barbara Vischioni; Viviana Vitolo; Richard Wheadon; Maria Giuseppina Bisogni
Journal:  Med Phys       Date:  2021-12-22       Impact factor: 4.506

5.  In-vivo range verification analysis with in-beam PET data for patients treated with proton therapy at CNAO.

Authors:  Martina Moglioni; Aafke Christine Kraan; Guido Baroni; Giuseppe Battistoni; Nicola Belcari; Andrea Berti; Pietro Carra; Piergiorgio Cerello; Mario Ciocca; Angelica De Gregorio; Micol De Simoni; Damiano Del Sarto; Marco Donetti; Yunsheng Dong; Alessia Embriaco; Maria Evelina Fantacci; Veronica Ferrero; Elisa Fiorina; Marta Fischetti; Gaia Franciosini; Giuseppe Giraudo; Francesco Laruina; Davide Maestri; Marco Magi; Giuseppe Magro; Etesam Malekzadeh; Michela Marafini; Ilaria Mattei; Enrico Mazzoni; Paolo Mereu; Alfredo Mirandola; Matteo Morrocchi; Silvia Muraro; Ester Orlandi; Vincenzo Patera; Francesco Pennazio; Marco Pullia; Alessandra Retico; Angelo Rivetti; Manuel Dionisio Da Rocha Rolo; Valeria Rosso; Alessio Sarti; Angelo Schiavi; Adalberto Sciubba; Giancarlo Sportelli; Sara Tampellini; Marco Toppi; Giacomo Traini; Antonio Trigilio; Serena Marta Valle; Francesca Valvo; Barbara Vischioni; Viviana Vitolo; Richard Wheadon; Maria Giuseppina Bisogni
Journal:  Front Oncol       Date:  2022-09-26       Impact factor: 5.738

6.  Monitoring Carbon Ion Beams Transverse Position Detecting Charged Secondary Fragments: Results From Patient Treatment Performed at CNAO.

Authors:  Marco Toppi; Guido Baroni; Giuseppe Battistoni; Maria Giuseppina Bisogni; Piergiorgio Cerello; Mario Ciocca; Patrizia De Maria; Micol De Simoni; Marco Donetti; Yunsheng Dong; Alessia Embriaco; Veronica Ferrero; Elisa Fiorina; Marta Fischetti; Gaia Franciosini; Aafke Christine Kraan; Carmela Luongo; Etesam Malekzadeh; Marco Magi; Carlo Mancini-Terracciano; Michela Marafini; Ilaria Mattei; Enrico Mazzoni; Riccardo Mirabelli; Alfredo Mirandola; Matteo Morrocchi; Silvia Muraro; Vincenzo Patera; Francesco Pennazio; Angelo Schiavi; Adalberto Sciubba; Elena Solfaroli-Camillocci; Giancarlo Sportelli; Sara Tampellini; Giacomo Traini; Serena Marta Valle; Barbara Vischioni; Viviana Vitolo; Alessio Sarti
Journal:  Front Oncol       Date:  2021-06-10       Impact factor: 6.244

7.  Inter-fractional monitoring of [Formula: see text]C ions treatments: results from a clinical trial at the CNAO facility.

Authors:  M Fischetti; G Baroni; G Battistoni; G Bisogni; P Cerello; M Ciocca; P De Maria; M De Simoni; B Di Lullo; M Donetti; Y Dong; A Embriaco; V Ferrero; E Fiorina; G Franciosini; F Galante; A Kraan; C Luongo; M Magi; C Mancini-Terracciano; M Marafini; E Malekzadeh; I Mattei; E Mazzoni; R Mirabelli; A Mirandola; M Morrocchi; S Muraro; V Patera; F Pennazio; A Schiavi; A Sciubba; E Solfaroli Camillocci; G Sportelli; S Tampellini; M Toppi; G Traini; S M Valle; B Vischioni; V Vitolo; A Sarti
Journal:  Sci Rep       Date:  2020-11-26       Impact factor: 4.379

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.