Literature DB >> 29868662

A blood-serum sulfide selective electrochemical sensor based on a 9,10-phenanthrenequinone-tethered graphene oxide modified electrode.

K S Shalini Devi1, Annamalai Senthil Kumar2.   

Abstract

The sulfide ion and its associated species (H2S and HS-) are widely referred to as toxic chemicals. However, at concentrations of ∼10-100 μM, it serves as a neurotransmitter and signaling agent in biological systems. Abnormalities in blood serum sulfide can be an indication of several diseases, including diabetes, wherein there is a significant reduction in the sulfide ion concentration (<10 μM). Herein, we wish report a 9,10-phenanthrenequinone (PQn) tethered graphene oxide (GO) modified glassy carbon electrode (GCE/GO@PQn) for the highly selective and stable electrocatalytic oxidation and flow injection analysis (FIA) of sulfide ions. The electrode exhibits a detection range of 1-100 μM, and is suitable for the common biochemical interference-free detection of blood serum sulfide in pH 7 phosphate buffer solution. The modified electrode was found to be tolerant of interfering chemicals such as cysteine, uric acid, ascorbic acid, nitrate, glucose, hydrogen peroxide, nitrate, nitrite and dissolved oxygen. This is unlike conventional redox mediator modified electrodes, which all show marked interference with the above-mentioned chemicals during sulfide detection. A constructed FIA calibration plot (applied potential, Eapp = 0.15 V vs. Ag/AgCl) was linear in the sulfide concentration ranges of 1-100 μM (1st region) and 300 μM-5 mM (2nd region) with a detection limit value of 700 nM. The selective and quick FIA of sulfide ions in three diabetic patient blood samples along with a control was demonstrated as a proof of concept.

Entities:  

Year:  2018        PMID: 29868662     DOI: 10.1039/c8an00756j

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  5 in total

1.  A turn-on fluorescent sulfide probe prepared from carbon dots and MnO2 nanosheets.

Authors:  Jinshui Liu; Chenfu Liu; Zihan Zhou
Journal:  Mikrochim Acta       Date:  2019-04-13       Impact factor: 5.833

Review 2.  Nitric Oxide and Hydrogen Sulfide Regulation of Ischemic Vascular Growth and Remodeling.

Authors:  Saranya Rajendran; Xinggui Shen; John Glawe; Gopi K Kolluru; Christopher G Kevil
Journal:  Compr Physiol       Date:  2019-06-12       Impact factor: 9.090

3.  Porous Carbon Nanofiber-Modified Carbon Fiber Microelectrodes for Dopamine Detection.

Authors:  Blaise J Ostertag; Michael T Cryan; Joel M Serrano; Guoliang Liu; Ashley E Ross
Journal:  ACS Appl Nano Mater       Date:  2022-01-21

4.  One-pot synthesis of AuAgPd trimetallic nanoparticles with peroxidase-like activity for colorimetric assays.

Authors:  Jiao Kong; Jie Zheng; Zimu Li; Jiabao Huang; Fanghui Cao; Qiong Zeng; Fang Li
Journal:  Anal Bioanal Chem       Date:  2021-07-07       Impact factor: 4.142

5.  Cellulose nanofiber-based electrode as a component of an enzyme-catalyzed biofuel cell.

Authors:  Masato Tominaga; Kazufumi Kuwahara; Masayuki Tsushida; Kenji Shida
Journal:  RSC Adv       Date:  2020-06-09       Impact factor: 4.036

  5 in total