Rune Becher1,2, Hanne Wellendorf1, Amrit Kaur Sakhi2, Jan Tore Samuelsen1, Cathrine Thomsen2, Anette Kocbach Bølling2, Hilde Molvig Kopperud1.
Abstract
BPA has been reported to leach from some resin based dental restorative materials and materials used for orthodontic treatment. To confirm and update previous findings, especially in light of the new temporary lower threshold value for tolerable daily BPA intake, we have investigated the leaching of BPA from 4 composite filling materials, 3 sealants and 2 orthodontic bonding materials. The materials were either uncured and dissolved in methanol or cured. The cured materials were kept in deionized water for 24 hours or 2 weeks. Samples were subsequently analyzed by ultra-performance liquid chromatography coupled to mass spectrometry (UPLC-MS-MS). The composite filling material Tetric EvoFlow® and the fissure sealant DELTON® showed significantly higher levels of BPA leaching compared to control samples for all test conditions (uncured, 24 h leaching and 2 weeks leaching). There were no significant differences in amount of leached BPA for any of the tested materials after 24 hours compared to 2 weeks. These results show that BPA is still released from some dental materials despite the general concern about potential adverse effects of BPA. However, the amounts of BPA were relatively low and most likely represent a very small contribution to the total BPA exposure.Entities:
Keywords: BPA leaching; Dental materials; health impact
Year: 2018 PMID: 29868625 PMCID: PMC5974758 DOI: 10.1080/23337931.2018.1476869
Source DB: PubMed Journal: Acta Biomater Odontol Scand ISSN: 2333-7931
Materials tested.
| Composites | Fissure sealants | Orthodontic bonding |
|---|---|---|
| Ceram.X® | Clinpro™ Sealant | Transbond™PLUS |
| Grandio® Flow | DELTON® | Band-Lok® |
| Filtek™ Supreme XTE | Helioseal® F | |
| Tetric EvoFlow® |
Study 1. Presence of BPA in uncured materials. Only materials with leaching significantly above control are shown.
| Material | Sample number | BPA leaching | BPA in thousands of sample weight |
|---|---|---|---|
| Control | 2 | 2.7 ± 0.2 | n.a |
| Tetric EvoFlow® | 3 | 22 ± 3 | 0.005 ± 0.001 |
| DELTON® | 3 | 87 ± 26 | 0.013 ± 0.001 |
Study 1. Total leaching of BPA from cured materials after immersion in deionized water for 24 h. Only materials with leaching significantly above controls are shown.
| Material | Sample number | BPA leaching | BPA leaching |
|---|---|---|---|
| Control | 3 | 1.7 ± 0.2 | n. a. |
| Tetric EvoFlow® | 3 | 7.3 ± 1.3 | 2.6 ± 0.5 |
| DELTON® | 3 | 6.2 ± 0.3 | 1.9 ± 0.1 |
Study 1. Total leaching of BPA from cured materials after immersion in deionized water for 2 weeks. Only materials with leaching significantly above controls are shown.
| Material | Sample number | BPA leaching | BPA leaching |
|---|---|---|---|
| Control | 3 | 1.6 ± 0.4 | n. a. |
| Tetric EvoFlow® | 3 | 8.7 ± 1.6. | 3.1 ± 0.6 |
| DELTON® | 3 | 9.2 ± 2.1 | 2.8 ± 0.7 |
Figure 1.Study 1. Total leaching of BPA from cured materials after immersion in deionized water for 24 h and 2 weeks (n = 3). Bars are shown as mean ± SD. p values <.05 was considered statistically significant. In the two-way ANOVA, there was a significant effect of the dental material factor, but not for the time factor. Moreover, there was no interaction between the two factors, allowing for Bonferroni post-tests within the dental material factor. *indicates significantly different from control at the same leaching time.
Study 2. Total leaching of BPA from cured materials after immersion in deionized water for 24 h.
| Material | Sample number | BPA leaching | BPA leaching |
|---|---|---|---|
| Control (Blank) | 3 | 0.00 ± 0.01 | n.a. |
| ceram.X® | 5 | 0.36 ± 0.06 | 0.13 ± 0.02 |
| Grandio® Flow | 5 | 0.08 ± 0.01 | 0.029 ± 0.005 |
| Filtek™ Supreme XTE | 5 | 0.6 ± 0.1 | 0.20 ± 0.04 |
| Tetric EvoFlow® | 5 | 6.5 ± 0.4 | 2.3 ± 0.2 |
| Clinpro™ Sealant | 5 | 0.17 ± 0.09 | 0.06 ± 0.03 |
| DELTON® | 5 | 9.6 ± 2.2 | 3.4 ± 0.8 |
| Helioseal® F | 5 | 0.04 ± 0.04 | 0.01 ± 0.01 |
| Transbond™ PLUS | 5 | 0.09 ± 0.02 | 0.033 ± 0.006 |
| Band-Lok® | 5 | 1.5 ± 0.6 | 0.5 ± 0.2 |
indicates significantly different from control.