| Literature DB >> 29866177 |
Seoyoung Choi1, Yong Beom Shin2, Soo-Yeon Kim3, Jonghyun Kim4.
Abstract
BACKGROUND: To provide effective interventions for spasticity, accurate and reliable spasticity assessment is essential. For the assessment, the Modified Tardieu Scale (MTS) has been widely used owing to its simplicity and convenience. However, it has poor or moderate accuracy and reliability.Entities:
Keywords: Accuracy; Assessment; Cerebral palsy; Inertia measurement unit (IMU); Joint angle; Modified Tardieu scale; Reliability; Spasticity
Mesh:
Year: 2018 PMID: 29866177 PMCID: PMC5987429 DOI: 10.1186/s12984-018-0388-5
Source DB: PubMed Journal: J Neuroeng Rehabil ISSN: 1743-0003 Impact factor: 4.262
Comparison of MTS (spasticity) assessments using IMU
| Existing studies | Magnetometer | Calibration | Clonus | Regular PSV | Accuracy | Reliability | Target | |
|---|---|---|---|---|---|---|---|---|
| MTS assessment using IMU | [ | X | X | X | X | O | unknown | Knee joint |
| [ | X | X | X | △ | X | O | Elbow joint | |
| [ | O | X | X | X | X | unknown | Ankle joint | |
| Spasticity assessment using IMU | [ | X | X | X | △ | X | O | Knee joint |
| [ | O | X | X | X | X | O | Knee / ankle joints | |
| Proposed system | iMTS | O | O | O | O | O | O | Knee / ankle joints |
The symbol in the Magnetometer column indicates whether it requires a magnetometer (X) or not (O); the symbol for Calibration indicates whether it requires calibration (X) or not (O); the symbol for Clonus indicates whether it considers clonus (X) or not (O); the symbol for Regular PSV indicate if it is achieved (O), incompletely achieved (△), and not considered (X); the symbol for Accuracy indicates whether the root mean square error of the joint angle is less than 4 deg. (X) or not (O); and the symbol for Reliability denotes whether both test-retest and inter-rater reliabilities are consistent (ICC > 0.8) (X) or not (O)
Fig. 1Schematic diagram of the MTS assessment. Except ROM measurement. SG: spasticity grading; AMR: angle of muscle reaction; AOC: angle of catch; IAOC: initial angle of clonus
Instruction of MTS assessment
| Joint | Knee joint | Ankle joint | |
|---|---|---|---|
| Extensor | Flexor | Plantar flexor | |
| Hip | 90° flexion | neutral position | |
| Knee | maximum extension to maximum flexion | maximum flexion to maximum extension | full extension |
| Ankle | N/A | maximum plantarflexion to maximum dorsiflexion | |
Note that MTS assessment is conducted in supine position
Fig. 2Definition of segment/joint angles and coordinates
Anatomical landmarks for attaching the IMU
| Knee joint | Ankle joint | |
|---|---|---|
| Manipulated segment | Shank: the lateral 1/3 surface of the shank, from the malleolus | Foot: the anterior 2nd metatarsal bone |
| Held segment | Thigh: the lateral 1/3 surface of the thigh, from epicondyle of the femur | Shank: the anterior 1/3 surface of the shank, from the tibia |
Fig. 3Compensation scheme of the x-axis rotation using rotation matrix
Fig. 4IMU-based joint angle calculation algorithm
Fig. 5Typical angular acceleration profiles during fast stretching
Fig. 6Typical knee/ankle joint angles, angular accelerations, and EMG data during fast stretching
Fig. 7Graphic user interface of the proposed system
Characteristics of study population
| Characteristics | Group 1 ( | Group 2 ( |
|---|---|---|
| Age (years) | 7.5 ± 3.1 | 5.5 ± 3.5 |
| Weight (kg) | 25.1 ± 14.5 | 15.1 ± 8.3 |
| Height (cm) | 119.7 ± 21.1 | 101.8 ± 23.5 |
| Male / Female | 11 / 7 | 6 / 4 |
| hemiplegia / bilateral / quadriplegia | 5 / 9 / 4 | 2 / 5 / 3 |
| GMFCS | I: 3, II: 8, III: 2, | I: 1, II: 1, III: 4, |
GMFCS: gross motor function classification scale [1]
Fig. 8Protocol of the reliability study. The 1st rater performed the preparing session before the test, and the 2nd rater performed the actual test. The 1st rater performed a re-test within 3 days after the initial test
Fig. 9Representative joint angle comparison between the IMU and Mocap
RMSE between the Mocap and IMU
| Motion | ROM accuracy (deg) | AMR accuracy (deg) | |||
|---|---|---|---|---|---|
| Mean (SD) | RMSE (SD) | Mean (SD) | RMSE (SD) | ||
| Knee extension | Mocap | 165.05 (6.48) | 2.24 (1.55) | 145.68 (7.31) | 2.95 (1.07) |
| IMU | 164.16 (7.20) | 147.53 (7.47) | |||
| Knee flexion | Mocap | 72.92 (5.43) | 3.05 (1.84) | 104.21 (8.34) | 3.97 (2.02) |
| IMU | 74.58 (6.91) | 105.53 (9.78) | |||
| Ankle dorsiflexion | Mocap | 32.92 (5.11) | 3.11 (2.91) | 5.91 (6.61) | 3.86 (1.86) |
| IMU | 30.08 (3.03) | 7.62 (7.65) | |||
SD denotes standard deviation
Test-retest and inter-rater reliabilities
| Test-retest reliability | Inter-rater reliability | |||||||
|---|---|---|---|---|---|---|---|---|
| Test (deg) | Re-test (deg) | ICC (95% CI) | 1st Rater (deg) | 2nd Rater (deg) | ICC (95% CI) | |||
| Knee flexor | ROM | cMTS | 139.19 (10.48) | 140.01 (8.59) | 0.71 (0.38–0.80) | 139.19 (10.48) | 139.66 (8.35) | 0.65 (0.43–0.77) |
| iMTS | 144.73 (11.61) | 142.34 (8.94) | 0.84 (0.55–0.92) | 144.73 (11.61) | 142.34 (8.94) | 0.81 (0.65–0.89) | ||
| AMR | cMTS | 122.94 (15.74) | 120.27 (12.60) | 0.50 (0.31–0.70) | 122.94 (15.74) | 125.88 (15.05) | 0.50 (0.17–0.73) | |
| iMTS | 126.59 (14.82) | 126.06 (14.32) | 0.89 (0.80–0.95) | 126.59 (14.82) | 126.78 (14.75) | 0.86 (0.63–0.95) | ||
| SA | cMTS | 16.25 (12.38) | 19.74 (11.09) | 0.63 (0.27–0.78) | 16.25 (12.38) | 19.74 (11.09) | 0.41 (0.48–0.61) | |
| iMTS | 18.63 (10.30) | 17.76 (10.01) | 0.81(0.74–0.91) | 18.63 (10.30) | 17.47 (10.56) | 0.80 (0.53–0.90) | ||
| Knee extensor | ROM | cMTS | 37.43 (16.16) | 46.00 (14.82) | 0.73 (0.35–0.79) | 37.43 (16.16) | 45.01 (19.02) | 0.79 (0.50–0.85) |
| iMTS | 47.91 (15.61) | 46.94 (9.86) | 0.83 (0.73–0.93) | 47.91 (15.61) | 45.25 (17.28) | 0.88 (0.57–0.92) | ||
| AMR | cMTS | 39.49 (18.38) | 45.76 (14.82) | 0.64 (0.32–0.78) | 39.49 (18.38) | 54.68 (17.82) | 0.59 (0.46–0.84) | |
| iMTS | 49.97 (16.08) | 47.73 (8.92) | 0.86 (0.74–0.93) | 49.97 (16.08) | 58.59 (16.01) | 0.84 (0.70–0.92) | ||
| SA | cMTS | −4.48 (3.59) | −5.15 (4.92) | 0.40 (0.24–0.59) | − 4.48 (3.59) | −9.67 (5.38) | 0.50 (0.10–0.73) | |
| iMTS | −5.20 (5.43) | −4.96 (4.46) | 0.81 (0.63–0.91) | −5.20 (5.43) | −12.13 (9.47) | 0.80 (0.54–0.86) | ||
| Ankle plantar-flexor | ROM | cMTS | 22.77 (7.49) | 24.44 (9.50) | 0.94 (0.43–0.97) | 22.77 (7.49) | 21.21 (7.82) | 0.94 (0.76–0.91) |
| iMTS | 22.29 (10.57) | 21.59 (8.78) | 0.92 (0.65–0.89) | 22.29 (10.57) | 24.78 (8.86) | 0.92 (0.66–0.92) | ||
| AMR | cMTS | 3.33 (7.57) | 4.67 (6.12) | 0.71 (0.46–0.78) | 3.33 (7.57) | 8.24 (9.82) | 0.63 (0.38–0.83) | |
| iMTS | 8.27 (3.29) | 6.40 (4.88) | 0.83 (0.55–0.90) | 8.27 (3.29) | 10.27 (6.92) | 0.83 (0.61–0.91) | ||
| SA | cMTS | 19.44 (7.72) | 19.47 (2.63) | 0.63 (0.01–0.45) | 19.44 (7.72) | 12.97 (9.92) | 0.19 (0.04–0.59) | |
| iMTS | 14.02 (8.44) | 15.19 (9.87) | 0.80 (0.68–0.96) | 14.02 (8.44) | 14.51 (9.46) | 0.81 (0.68–0.89) | ||
CI denotes the confidence interval
Cause of reliability deterioration of AMR in the MTS assessment
| Test-retest (ICC) | Knee flexor | Knee extensor | Ankle |
| cMTS | 0.50 (0.31–0.70) | 0.64 (0.32–0.78) | 0.71 (0.46–0.78) |
| cMTS with IMU | 0.78 (0.51–0.88) | 0.74 (0.44–0.90) | 0.77 (0.54–0.87) |
| cMTS with VB | 0.71 (0.49–0.79) | 0.82 (0.60–0.91) | 0.79 (0.67–0.86) |
| iMTS | 0.89 (0.80–0.95) | 0.86 (0.74–0.93) | 0.83 (0.55–0.90) |
| Inter-rater (ICC) | Knee flexor | Knee extensor | Ankle |
| cMTS | 0.50 (0.17–0.73) | 0.59 (0.46–0.84) | 0.63 (0.38–0.83) |
| cMTS with IMU | 0.65 (0.49–0.76) | 0.78 (0.67–0.84) | 0.69 (0.59–0.77) |
| cMTS with VB | 0.76 (0.53–0.81) | 0.75 (0.66–0.82) | 0.72 (0.61–0.82) |
| iMTS | 0.86 (0.63–0.95) | 0.84 (0.70–0.92) | 0.83 (0.61–0.91) |
All data are presented as ICCs (95% CI); VB denotes visual biofeedback
Duration of clonus
| Mean (SD) | ICC (95% CI) | |
|---|---|---|
| iMTS | 7.02 (5.01) | 0.96 (0.89–0.98) |
| EMG | 7.09 (4.78) |
Achieving rate of the target PSV
| 1st rater | 2nd rater | ||
|---|---|---|---|
| Test (%) | Re-test (%) | Test (%) | |
| Knee flexor | 75 | 80 | 78 |
| Knee extensor | 77 | 75 | 83 |
| Ankle plantar-flexor | 80 | 76 | 77 |
| Average (%) | 77 | ||