Assessment of acetabular version in total hip arthroplasty: an application of Widmer's technique in a regional setting.

Jason Trieu1, Alexandra E F Hadden2, Alasdair G Sutherland1,3.   

Abstract

BACKGROUND: Acetabular prosthesis positioning in total hip arthroplasty is important in reducing the risk of dislocation. Assessment of version by computed tomography scan is expensive and involves a large radiation dose. We wished to assess the value of Widmer's technique, utilizing readily available radiographs, to determine cup anteversion.
METHODS: Patients who underwent primary total hip arthroplasty by the senior author (AGS) at a single regional hospital over a 5-year period were eligible for inclusion. Measurements were performed using the technique described by Widmer, utilizing standard post-operative radiographs. Statistical analysis was undertaken in SPSS v22. Significance was accepted at P < 0.05.
RESULTS: Assessment included 109 hips in 99 patients; 63 hips with cemented cups and 46 hips with uncemented cups. Mean acetabular anteversion in the cemented group was 11.9° (0-27.7, SD: 7) and in the uncemented group was 14.1° (10.3-32.7, SD: 7.1); this difference trended towards statistical significance (P = 0.09). Test-retest measurements showed high degree of correlation (Pearson test: 0.927, P < 0.001). There were 96 of 109 hips positioned in the Lewinnek safe zone of 5-25° anteversion. The crude dislocation rate in our cohort was 6.4% (7 of 109 hips) with all dislocations occurring in hips placed in the safe zone.
CONCLUSION: Widmer's technique is a reliable method for calculating acetabular version in a regional hospital setting and offers the individual surgeon a ready technique of personal quality control. Cup version was not a significant factor contributing to dislocation rates in our series.
© 2018 Royal Australasian College of Surgeons.

Entities:  

Keywords:  acetabular anteversion; acetabular prosthesis; hip dislocation; plain radiograph; total hip arthroplasty

Mesh:

Substances:

Year:  2018        PMID: 29864258     DOI: 10.1111/ans.14506

Source DB:  PubMed          Journal:  ANZ J Surg        ISSN: 1445-1433            Impact factor:   1.872


  1 in total

1.  Lewinnek Safe Zone References are Frequently Misquoted.

Authors:  Aonnicha Burapachaisri; Ameer Elbuluk; Edem Abotsi; Jim Pierrepont; Seth A Jerabek; Aaron J Buckland; Jonathan M Vigdorchik
Journal:  Arthroplast Today       Date:  2020-11-26
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.