The influence of the electrodes spacing of a mapping catheter on the atrial voltage substrate map.

Hitoshi Mori1, Ritsushi Kato2, Yoshifumi Ikeda1, Koji Goto1, Sayaka Tanaka1, So Asano1, Yuichiro Shiki1, Takahiko Nagase1, Mai Tahara1, Shiro Iwanaga1, Toshihiro Muramatsu1, Kazuo Matsumoto1.   

Abstract

BACKGROUND: Detailed substrate mapping is important for catheter ablation. However, the influence of the electrode spacing of the mapping catheter on the substrate map has not been well clarified. The aim of this study was to investigate the influence of the electrode spacing of the mapping catheter on the voltage of the substrate map.
METHODS: Protocol 1: We recorded the local atrial potentials of the left atrium (LA) using the ablation catheter during sinus rhythm in six atrial fibrillation (AF) patients. The voltage of each atrial potential was compared between a close-bipolar (1-2 electrode) recording and wide-bipolar (1-4 electrode) recording. Protocol 2: Two voltage-maps of the LA were constructed separately using a 20-pole circular catheter and 10-pole circular catheter during sinus rhythm in 42 AF patients. The low voltage zone (LVZ) (<0.5mV) areas obtained by 2 voltage maps using the 10-pole and 20-pole circular catheters were compared.
RESULTS: Protocol 1: The close-bipolar voltage of the local potentials was significantly smaller than that of the wide-bipolar voltages (0.76±0.39mV vs. 0.63±0.41mV, p<0.0001). Protocol 2: The size of the LVZ areas identified by the 10-pole and 20-pole catheters was 1.12±1.92cm2 (1.47±2.78%) and 8.30±7.80cm2 (8.83±8.32%), respectively (p<0.0001).
CONCLUSIONS: The voltage of the local atrial potential using the close-bipolar catheter was significantly smaller than that using the wide-bipolar catheter. Care should be given to the electrode spacing of mapping catheters when analyzing the voltage of the atrial myocardial potentials.
Copyright © 2018. Published by Elsevier Ltd.

Entities:  

Keywords:  Ablation; Arrhythmia; Atrial fibrillation; Low voltage zone; Substrate

Mesh:

Year:  2018        PMID: 29859827     DOI: 10.1016/j.jjcc.2018.04.012

Source DB:  PubMed          Journal:  J Cardiol        ISSN: 0914-5087            Impact factor:   3.159


  2 in total

1.  Comparison of Unipolar and Bipolar Voltage Mapping for Localization of Left Atrial Arrhythmogenic Substrate in Patients With Atrial Fibrillation.

Authors:  Deborah Nairn; Heiko Lehrmann; Björn Müller-Edenborn; Steffen Schuler; Thomas Arentz; Olaf Dössel; Amir Jadidi; Axel Loewe
Journal:  Front Physiol       Date:  2020-11-26       Impact factor: 4.566

2.  Comparison of the empirical linear ablation and low voltage area-guided ablation in addition to pulmonary vein isolation in patients with persistent atrial fibrillation: a propensity score-matched analysis.

Authors:  Noriyuki Suzuki; Shinji Kaneko; Masaya Fujita; Masanori Shinoda; Ryuji Kubota; Taiki Ohashi; Yosuke Tatami; Junya Suzuki; Hitomi Hori; Kentaro Adachi; Ryota Ito; Yoshinori Shirai; Satoshi Yanagisawa; Yasuya Inden; Toyoaki Murohara
Journal:  BMC Cardiovasc Disord       Date:  2022-01-22       Impact factor: 2.298

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.