Masashi Nakamura1, Tomoyuki Kido2, Teruhito Kido2, Kouki Watanabe3, Michaela Schmidt4, Christoph Forman4, Teruhito Mochizuki2. 1. Department of Radiology, Ehime University Graduate School of Medicine, Matsuyama, Ehime, Japan. Electronic address: m.nakamura1230@gmail.com. 2. Department of Radiology, Ehime University Graduate School of Medicine, Matsuyama, Ehime, Japan. 3. Department of Cardiology, Saiseikai Matsuyama Hospital, Matsuyama, Ehime, Japan. 4. Siemens Healthcare GmbH, Germany.
Abstract
OBJECTIVES: Whole-heart coronary magnetic resonance angiography (MRA) is a promising non-contrast, radiation-free technique for assessing the coronary artery. Yet, a disadvantage of coronary MRA is the relatively long acquisition time. The purpose of this study was to evaluate the scan time and image quality of compressed sensing (CS) coronary MRA compared with conventional coronary MRA. MATERIALS AND METHODS: Twenty healthy volunteers underwent navigator-gated coronary MRA with a CS prototype sequence and conventional navigator-gated coronary MRA on a clinical 3T MRI scanner without contrast medium. The spatial resolutions were 1.33 × 1.33 × 1.20 mm3 for CS and 1.33 × 1.33 × 1.48 mm3 interpolated to 0.70 × 0.70 × 1.20 mm3 for conventional, respectively. We compared acquisition times, rated image quality on a 4-point scale (RCA; proximal, middle, and distal, LAD; main, proximal, middle, and distal, LCX; proximal and distal), and measured the visualized vessel lengths of three vessels. RESULTS: The mean acceptance rates were 44.9% for CS coronary MRA and 48.7% for conventional coronary MRA (p = .39). The mean effective scan time was 3 min 45 s for CS coronary MRA and 15 min 6 s for conventional coronary MRA (p < 0.001). Image quality scores were significantly lower for CS coronary MRA than for conventional coronary MRA (3.4 ± 0.7 for CS vs. 3.8 ± 0.4 for conventional; p < 0.0001). Conventional coronary MRA images were scored >3.4 in all segments on average, while CS coronary MRA images were scored >3.2 (good quality for diagnosis) in almost all segments, with only the distal RCA segment graded 2.9 on average. The average visible vessel lengths for CS and conventional coronary MRA were as follows: 11.5 ± 4.4 cm and 12.5 ± 4.8 cm for the RCA, respectively (p < 0.05, 95% limits of agreement [LOA]; -3.6 to 1.6 cm); 10.6 ± 3.0 cm and 11.1 ± 2.9 cm for the LAD, respectively (p = .15, 95% LOA -4.0 to 2.8 cm); and 7.1 ± 2.2 cm and 8.2 ± 2.5 cm for the LCX, respectively (p < 0.05, 95% LOA -4.0 to 1.7 cm). CONCLUSIONS: Non-contrast coronary MRA using CS could largely shorten acquisition time, compared with conventional navigator-gated coronary MRA, while maintaining acceptable visualization at 3T.
OBJECTIVES: Whole-heart coronary magnetic resonance angiography (MRA) is a promising non-contrast, radiation-free technique for assessing the coronary artery. Yet, a disadvantage of coronary MRA is the relatively long acquisition time. The purpose of this study was to evaluate the scan time and image quality of compressed sensing (CS) coronary MRA compared with conventional coronary MRA. MATERIALS AND METHODS: Twenty healthy volunteers underwent navigator-gated coronary MRA with a CS prototype sequence and conventional navigator-gated coronary MRA on a clinical 3T MRI scanner without contrast medium. The spatial resolutions were 1.33 × 1.33 × 1.20 mm3 for CS and 1.33 × 1.33 × 1.48 mm3 interpolated to 0.70 × 0.70 × 1.20 mm3 for conventional, respectively. We compared acquisition times, rated image quality on a 4-point scale (RCA; proximal, middle, and distal, LAD; main, proximal, middle, and distal, LCX; proximal and distal), and measured the visualized vessel lengths of three vessels. RESULTS: The mean acceptance rates were 44.9% for CS coronary MRA and 48.7% for conventional coronary MRA (p = .39). The mean effective scan time was 3 min 45 s for CS coronary MRA and 15 min 6 s for conventional coronary MRA (p < 0.001). Image quality scores were significantly lower for CS coronary MRA than for conventional coronary MRA (3.4 ± 0.7 for CS vs. 3.8 ± 0.4 for conventional; p < 0.0001). Conventional coronary MRA images were scored >3.4 in all segments on average, while CS coronary MRA images were scored >3.2 (good quality for diagnosis) in almost all segments, with only the distal RCA segment graded 2.9 on average. The average visible vessel lengths for CS and conventional coronary MRA were as follows: 11.5 ± 4.4 cm and 12.5 ± 4.8 cm for the RCA, respectively (p < 0.05, 95% limits of agreement [LOA]; -3.6 to 1.6 cm); 10.6 ± 3.0 cm and 11.1 ± 2.9 cm for the LAD, respectively (p = .15, 95% LOA -4.0 to 2.8 cm); and 7.1 ± 2.2 cm and 8.2 ± 2.5 cm for the LCX, respectively (p < 0.05, 95% LOA -4.0 to 1.7 cm). CONCLUSIONS: Non-contrast coronary MRA using CS could largely shorten acquisition time, compared with conventional navigator-gated coronary MRA, while maintaining acceptable visualization at 3T.
Authors: Uzair Ansari; Sonja Janssen; Stefan Baumann; Martin Borggrefe; Stephan Waldeck; Stefan Schönberg; Theano Papavassiliu; Daniel Overhoff Journal: Herz Date: 2022-01-10 Impact factor: 1.443
Authors: Adriana Argentiero; Giuseppe Muscogiuri; Mark G Rabbat; Chiara Martini; Nicolò Soldato; Paolo Basile; Andrea Baggiano; Saima Mushtaq; Laura Fusini; Maria Elisabetta Mancini; Nicola Gaibazzi; Vincenzo Ezio Santobuono; Sandro Sironi; Gianluca Pontone; Andrea Igoren Guaricci Journal: J Clin Med Date: 2022-05-19 Impact factor: 4.964
Authors: Aryan Zahergivar; Madison Kocher; Jeffrey Waltz; Ismail Kabakus; Jordan Chamberlin; Selcuk Akkaya; Ali M Agha; U Joseph Schoepf; Jeremy R Burt Journal: Heliyon Date: 2021-03-18