Literature DB >> 29856617

Protocol for Determining Ultraviolet Light Emitting Diode (UV-LED) Fluence for Microbial Inactivation Studies.

Ataollah Kheyrandish1, Madjid Mohseni1, Fariborz Taghipour1.   

Abstract

Determining fluence is essential to derive the inactivation kinetics of microorganisms and to design ultraviolet (UV) reactors for water disinfection. UV light emitting diodes (UV-LEDs) are emerging UV sources with various advantages compared to conventional UV lamps. Unlike conventional mercury lamps, no standard method is available to determine the average fluence of the UV-LEDs, and conventional methods used to determine the fluence for UV mercury lamps are not applicable to UV-LEDs due to the relatively low power output, polychromatic wavelength, and specific radiation profile of UV-LEDs. In this study, a method was developed to determine the average fluence inside a water suspension in a UV-LED experimental setup. In this method, the average fluence was estimated by measuring the irradiance at a few points for a collimated and uniform radiation on a Petri dish surface. New correction parameters were defined and proposed, and several of the existing parameters for determining the fluence of the UV mercury lamp apparatus were revised to measure and quantify the collimation and uniformity of the radiation. To study the effect of polychromatic output and radiation profile of the UV-LEDs, two UV-LEDs with peak wavelengths of 262 and 275 nm and different radiation profiles were selected as the representatives of typical UV-LEDs applied to microbial inactivation. The proper setup configuration for microorganism inactivation studies was also determined based on the defined correction factors.

Entities:  

Mesh:

Year:  2018        PMID: 29856617     DOI: 10.1021/acs.est.7b05797

Source DB:  PubMed          Journal:  Environ Sci Technol        ISSN: 0013-936X            Impact factor:   9.028


  2 in total

1.  Application of a novel, continuous-feeding ultraviolet light emitting diode (UV-LED) system to disinfect domestic wastewater for discharge or agricultural reuse.

Authors:  Thi Minh Hong Nguyen; Poonyanooch Suwan; Thammarat Koottatep; Sara E Beck
Journal:  Water Res       Date:  2019-01-16       Impact factor: 11.236

2.  Ultraviolet disinfection of Schistosoma mansoni cercariae in water.

Authors:  Lucinda Hazell; Fiona Allan; Aidan M Emery; Michael R Templeton
Journal:  PLoS Negl Trop Dis       Date:  2021-07-06
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.