Literature DB >> 29852384

Ractopamine analysis in pig kidney, liver and lungs: A validation of the method scope extension using QuEChERS as a sample preparation step.

Vivian Feddern1, Carolina Naves Aroeira2, Luciano Molognoni3, Vanessa Gressler4, Heitor Daguer3, Osmar Antonio Dalla Costa4, Carmen Josefina Contreras Castillo2, Gustavo Julio Mello Monteiro de Lima4.   

Abstract

Ractopamine has been allowed by some countries as a repartitioning additive in pig diet, since it promotes protein synthesis and fat lipolysis. Most regulatory agencies only propose the ractopamine assessment in meat, kidney, liver and fat. Aiming at contributing to the scarcity data regarding this analyte in pig lungs, we extended the scope of a LC-MS method to evaluate pig offals. Homogenized tissue samples were extracted by a QuEChERS procedure; following by clean up steps and further tandem mass spectrometry determination. Method performance was evaluated through specificity, recovery, linearity, reproducibility, repeatability, decision limit (CCα), and detection capability (CCβ), in accordance to the Commission Decision 2002/657/EC. Regression coefficients (R2) between 0.994 and 0.999 were achieved for kidney, liver and lungs. Recoveries ranged from 92.0 to 127%. CCα and CCβ values ranged from 3.65 to 4.86 μg kg-1, and from 6.27 to 7.21 μg kg-1, respectively. These values were under the maximum residue limits suggested by Codex Alimentarius, which are 90 and 40 μg kg-1 for kidney and liver, respectively. When applied to real samples up to 22.5, 92 and 1003 μg kg-1 of ractopamine residues were detected in pig liver, kidney and lungs, respectively. The results allowed concluding that the proposed analytical method is capable to detect ractopamine residues in all evaluated matrices. Therefore, it can be successfully applied and used as a routine method in laboratories of residue analysis.
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Food safety; Hydrolysis; LC-MS; Matrix effect; Maximum residue limit; β-Agonists

Mesh:

Substances:

Year:  2018        PMID: 29852384     DOI: 10.1016/j.jchromb.2018.05.033

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  1 in total

1.  Determination of the Metabolites and Metabolic Pathways for Three β-Receptor Agonists in Rats Based on LC-MS/MS.

Authors:  Ying Liang; Lin Wang; Ruipeng Zhang; Jiadi Pan; Wenhong Wu; Yuanyuan Huang; Zifan Zhang; Renbang Zhao
Journal:  Animals (Basel)       Date:  2022-07-23       Impact factor: 3.231

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.