Literature DB >> 29851027

Impact of resuscitation fluid bag size availability on volume of fluid administration in the intensive care unit.

S Horst1, R Kawati1, J Rasmusson2, A Pikwer3, M Castegren4, M Lipcsey1,5.   

Abstract

BACKGROUND: Iatrogenic fluid overload is associated with increased mortality in the intensive care unit (ICU). Decisions on fluid therapy may, at times, be based on other factors than physiological endpoints. We hypothesized that because of psychological factors volume of available fluid bags would affect the amount of resuscitation fluid administered to ICU patients.
METHODS: We performed a prospective intervention cross-over study at 3 Swedish ICUs by replacing the standard resuscitation fluid bag of Ringer's Acetate 1000 mL with 500 mL bags (intervention group) for 5 separate months and then compared it with the standard bag size for 5 months (control group). Primary endpoint was the amount of Ringer's Acetate per patient during ICU stay. Secondary endpoints were differences between the groups in cumulative fluid balance and change in body weight, hemoglobin and creatinine levels, urine output, acute kidney failure (measured as the need for renal replacement therapy, RRT) and 90-day mortality.
RESULTS: Six hundred and thirty-five ICU patients were included (291 in the intervention group, 344 in the control group). There was no difference in the amount of resuscitation fluid per patient during the ICU stay (2200 mL [1000-4500 median IQR] vs 2245 mL [1000-5630 median IQR]), RRT rate (11 vs 9%), 90-day mortality (11 vs 10%) or total fluid balance between the groups. The daily amount of Ringer's acetate administered per day was lower in the intervention group (1040 (280-2000) vs 1520 (460-3000) mL; P = .03).
CONCLUSIONS: The amount of resuscitation fluid administered to ICU patients was not affected by the size of the available fluid bags. However, altering fluid bag size could have influenced fluid prescription behavior.
© 2018 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  adverse effects; critical care; crystalloid solutions; fluid therapy; psychological factors

Mesh:

Substances:

Year:  2018        PMID: 29851027     DOI: 10.1111/aas.13161

Source DB:  PubMed          Journal:  Acta Anaesthesiol Scand        ISSN: 0001-5172            Impact factor:   2.105


  1 in total

1.  An Effective Behavioral Nudge in the Operating Room.

Authors:  Nita Khandelwal; Sean D Sullivan
Journal:  Anesthesiology       Date:  2020-05       Impact factor: 7.892

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.