Literature DB >> 29850956

PEKK-made indirect temporary crowns and bridges: a clinical pilot study.

T Klur1, Istabrak Hasan2,3, K Ottersbach4, H Stark5, M Fichte5, C Dirk6, C Bourauel6.   

Abstract

OBJECTIVES: The aim of the present study was to find out whether the high-performance polymer PEKK is an equivalent alternative compared to cobalt chrome (CoCr)-made restorations, regarding to biocompatibility, stability, and comfort.
MATERIALS AND METHODS: Twenty-two patients (m, 10; f, 12) who were indicated for a long-term temporary-fixed restoration were included. They were randomized through a lottery procedure into two groups: the first group was restored with veneered PEKK-made crowns and bridges (Pekkton ivory), while the second group was restored with veneered CoCr crowns. Clinical parameters (plaque index (PI), probing depth (PD), fracture, and chipping) were documented in a period of 3-5 months from the insertion of restoration. Furthermore, every patient completed the OHIP-14 questionnaire. An exchange of the restorations from the first to the alternative material was performed after a period of 3-5 months.
RESULTS: All patients showed an improvement of the oral hygiene and probing depth after insertion of the temporary restorations. However, there were no significant differences between PEKK and CoCr-made restorations (P > 0.05). There was no chipping after 5 months for both kinds of materials. There was a noticeable reduction of pain and discomfort of patients after insertion of temporary restorations. However, there were no significant differences between the two materials (P > 0.05).
CONCLUSIONS: PEKK-made temporary restorations offer a good and stable alternative to CoCr-made restorations. They have a high aesthetical advantage over CoCr restoration. CLINICAL RELEVANCE: Esthetic and price-efficient temporary crowns can be offered for the patient during periodontal therapy to improve its success, in particular by improving the oral hygiene.

Entities:  

Keywords:  Bridges; CoCr; Indirect temporary crowns; PEKK

Mesh:

Substances:

Year:  2018        PMID: 29850956     DOI: 10.1007/s00784-018-2493-z

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  3 in total

1.  Combination of Polydopamine Coating and Plasma Pretreatment to Improve Bond Ability Between PEEK and Primary Teeth.

Authors:  Rui Teng; Yuchen Meng; Xiaodan Zhao; Jie Liu; Rui Ding; Yilong Cheng; Yunhe Zhang; Yanfeng Zhang; Dandan Pei; Ang Li
Journal:  Front Bioeng Biotechnol       Date:  2021-01-29

2.  Comparison of two resilient attachment systems for implant-/mucosa-supported overdentures with a PEKK framework: a clinical pilot study.

Authors:  Christoph Bourauel; Helmut Stark; Istabrak Dörsam; Anastasia Hombach
Journal:  Clin Oral Investig       Date:  2021-12-21       Impact factor: 3.573

3.  New Intraoral Scanner-Based Chairside Measurement Method to Investigate the Internal Fit of Crowns: A Clinical Trial.

Authors:  Maximiliane Amelie Schlenz; Jonas Vogler; Alexander Schmidt; Peter Rehmann; Bernd Wöstmann
Journal:  Int J Environ Res Public Health       Date:  2020-03-25       Impact factor: 3.390

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.