Literature DB >> 29848162

Using near-infrared reflectance spectroscopy (NIRS) to assess distal-limb perfusion on venoarterial (V-A) extracorporeal membrane oxygenation (ECMO) patients with femoral cannulation.

Killian Patton-Rivera1, James Beck1, Kenmond Fung1, Christine Chan1, Matthew Beck1, Hiroo Takayama1, Koji Takeda1.   

Abstract

BACKGROUND: Patients requiring V-A ECMO who receive femoral cannulation have an associated risk of distal, lower-limb hypoperfusion and ischemia of the cannulated leg. This pilot study evaluated the usefulness of non-invasive lower-limb oximetry, using near-infrared reflectance spectroscopy (NIRS) to detect limb ischemia.
METHODS: Between June 2016 and January 2017, 25 patients receiving femoral V-A ECMO were continuously monitored using the CASMED Fore-Sight Elite (CAS Medical Systems Inc., Branford, CT) tissue oximeter. A retrospective pilot study was conducted to review the correlation between NIRS tissue saturations (StO2) and clinical indications of limb ischemia. Patients were monitored for StO2s less than 50% for more than four minutes or StO2 differentials between the cannulated and non-cannulated legs greater than 15%.
RESULTS: Twenty-five patients (age 22-78) were monitored with NIRS. Six patients had clinical indications of lower-limb ischemia: cold limb, mottled skin and pulseless Doppler ultrasound. All six patients had StO2s below 50% that persisted for longer than four minutes. Of the 25 patients, one patient had a false-positive indication of hypoperfusion with StO2 below 50% for more than four minutes due to a venous saturation below 30%. Another patient had a false-positive pulseless Doppler ultrasound caused by high doses of pressor support. The StO2 was greater than 60%, which confirmed the clinical determination of adequate perfusion. Five patients had StO2s below 50% for less than four minutes and none of these patients had clinical indications of lower-limb hypoperfusion. All patients with cannula-related obstruction of flow to the distal portion of the leg had StO2 differentials greater than 15%. No patients without cannula-related obstruction to flow had StO2 differentials greater than 15%.
CONCLUSION: Advancements in NIRS technology seem to have improved its accuracy for continuous, non-invasive monitoring of regional tissue and may provide clinicians with an additional metric to protect the distal portion of the cannulated leg.

Entities:  

Keywords:  distal-limb perfusion; extracorporeal membrane oxygenation; femoral cannulation; limb ischemia; near-infrared reflectance spectroscopy; non-invasive monitoring

Mesh:

Year:  2018        PMID: 29848162     DOI: 10.1177/0267659118777670

Source DB:  PubMed          Journal:  Perfusion        ISSN: 0267-6591            Impact factor:   1.972


  10 in total

1.  Vascular complications based on mode of extracorporeal membrane oxygenation.

Authors:  Juliet Blakeslee-Carter; Connie Shao; Ryan LaGrone; Irina Gonzalez-Sigler; Danielle C Sutzko; Benjamin Pearce; Kyle Eudailey; Emily Spangler; Adam W Beck; Graeme E McFarland
Journal:  J Vasc Surg       Date:  2022-01-26       Impact factor: 4.860

2.  Diagnosis of skin and soft tissue infections using near-infrared spectroscopy.

Authors:  Marina Oi; Takaaki Maruhashi; Kenichi Kumazawa; Saori Iwakawa; Yutaro Kurihara; Jyunpei Wato; Yuta Niimi; Akira Takeda; Yasushi Asari
Journal:  Acute Med Surg       Date:  2021-05-03

3.  A modified axillo-femoral perfusion for acute type a aortic dissection accompanied with lower limb malperfusion.

Authors:  Qianzhen Li; Liangwan Chen; Yue Shen; Jiahui Li; Yi Dong
Journal:  J Cardiothorac Surg       Date:  2020-01-09       Impact factor: 1.637

4.  Arterial and venous vascular complications in patients requiring peripheral venoarterial extracorporeal membrane oxygenation.

Authors:  Christoph Fisser; Corina Armbrüster; Clemens Wiest; Alois Philipp; Maik Foltan; Dirk Lunz; Karin Pfister; Roland Schneckenpointner; Christof Schmid; Lars S Maier; Thomas Müller; Matthias Lubnow
Journal:  Front Med (Lausanne)       Date:  2022-07-28

5.  Limb Ischemia Complications of Veno-Arterial Extracorporeal Membrane Oxygenation.

Authors:  Sixiong Hu; Andong Lu; Chenliang Pan; Bo Zhang; Yong Ling Wa; Wenjing Qu; Ming Bai
Journal:  Front Med (Lausanne)       Date:  2022-07-15

6.  Near-Infrared Spectroscopy for Determination of Cardiac Output Augmentation in a Swine Model of Ischemia-Reperfusion Injury.

Authors:  Nathan T P Patel; T Wesley Templeton; Magan R Lane; Timothy K Williams; Lucas P Neff; Eduardo J Goenaga-Diaz
Journal:  Crit Care Explor       Date:  2022-08-15

7.  When to use central mechanical support devices.

Authors:  Michael Salna; Yoshifumi Naka
Journal:  JTCVS Open       Date:  2020-03-21

Review 8.  Overview of Veno-Arterial Extracorporeal Membrane Oxygenation (VA-ECMO) Support for the Management of Cardiogenic Shock.

Authors:  Adamantios Tsangaris; Tamas Alexy; Rajat Kalra; Marinos Kosmopoulos; Andrea Elliott; Jason A Bartos; Demetris Yannopoulos
Journal:  Front Cardiovasc Med       Date:  2021-07-07

9.  Commentary: Axillary or femoral cannulation-Which is the lesser of 2 evils?

Authors:  Koji Takeda; Serge Kobsa; Yuji Kaku; Hiroo Takayama
Journal:  JTCVS Tech       Date:  2020-12-07

10.  Assessment of bedside lower limb angiography combined with continuous NIRS monitoring for the detection of lower limb complications of VA-ECMO: an observational monocentric study.

Authors:  Matthieu Koszutski; Mathieu Mattei; Juan Pablo Maureira; Antoine Kimmoun; Bruno Levy
Journal:  Crit Care       Date:  2021-07-31       Impact factor: 9.097

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.