Hybrid 99mTc-magnetite tracer for dual modality sentinel lymph node mapping.

Aidan Cousins1, Chris Tsopelas2, George Balalis3, Sarah K Thompson3, Dylan Bartholomeusz2, A Bruce Wedding4, Benjamin Thierry5.   

Abstract

Accuracy of sentinel lymph node identification using radioactive tracers in non-superficial cancers can be limited by radiation shine through and low spatial resolution of detection systems such as intraoperative gamma probes. By utilising a dual radioactive/magnetic tracer, sensitive lymphoscintigraphy can be paired with high spatial resolution intraoperative magnetometer probes to improve the accuracy of sentinel node detection in cancers with complex multidirectional lymphatic drainage. Dextran-coated magnetite nanoparticles (33 nm mean hydrodynamic diameter) were labelled with 99mTc and applied as a lymphotropic tracer in small and large animal models. The dual tracer could be radiolabelled with 98 ± 2% efficiency after 10 min of incubation at room temperature. Biodistribution studies of the tracer were conducted in normal rats (subdermal and intravenous tail delivery, n = 3) and swine (subdermal hind limb delivery, n = 5). In rats the dual tracer migrated through four tiers of lymph node, 20 min after subdermal injection. Results from intravenous biodistribution test for radiocolloids demonstrated no aggregation in vivo, however indicated the presence of some lower-molecular weight radioactive impurities (99mTc-dextran). In swine, the dual tracer could be effectively used to map lymphatic drainage from hind hoof to popliteal and inguinal basins using intraoperative gamma and magnetometer probes. Of the eight primary nodes excised, eight were positively identified by gamma probe and seven by magnetometer probe. The high-purity dual tracer shows early promise for sentinel node identification in complex lymphatic environments by combining sensitive preoperative lymphoscintigraphy with a high-resolution intraoperative magnetometer probe.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 29845339     DOI: 10.1007/s10856-018-6080-2

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  38 in total

Review 1.  Multifunctional radiolabeled nanoparticles for targeted therapy.

Authors:  G Ferro-Flores; B E Ocampo-García; C L Santos-Cuevas; E Morales-Avila; E Azorín-Vega
Journal:  Curr Med Chem       Date:  2014       Impact factor: 4.530

Review 2.  Hybrid tracers for sentinel node biopsy.

Authors:  N S Van Den Berg; T Buckle; G I Kleinjan; W M Klop; S Horenblas; H G Van Der Poel; R A Valdés-Olmos; F I Van Leeuwen
Journal:  Q J Nucl Med Mol Imaging       Date:  2014-06       Impact factor: 2.346

3.  Non-invasive mapping of deep-tissue lymph nodes in live animals using a multimodal PET/MRI nanoparticle.

Authors:  Daniel L J Thorek; David Ulmert; Ndeye-Fatou M Diop; Mihaela E Lupu; Michael G Doran; Ruimin Huang; Diane S Abou; Steven M Larson; Jan Grimm
Journal:  Nat Commun       Date:  2014       Impact factor: 14.919

4.  In vivo evaluation of (64)Cu-labeled magnetic nanoparticles as a dual-modality PET/MR imaging agent.

Authors:  Charles Glaus; Raffaella Rossin; Michael J Welch; Gang Bao
Journal:  Bioconjug Chem       Date:  2010-04-21       Impact factor: 4.774

5.  Three-field lymphadenectomy and pattern of lymph node spread in T3 adenocarcinoma of the distal esophagus and the gastro-esophageal junction.

Authors:  C van de Ven; P De Leyn; W Coosemans; D Van Raemdonck; T Lerut
Journal:  Eur J Cardiothorac Surg       Date:  1999-06       Impact factor: 4.191

6.  Intraoperative laparoscopic fluorescence guidance to the sentinel lymph node in prostate cancer patients: clinical proof of concept of an integrated functional imaging approach using a multimodal tracer.

Authors:  Henk G van der Poel; Tessa Buckle; Oscar R Brouwer; Renato A Valdés Olmos; Fijs W B van Leeuwen
Journal:  Eur Urol       Date:  2011-04-01       Impact factor: 20.096

7.  Concomitant radio- and fluorescence-guided sentinel lymph node biopsy in squamous cell carcinoma of the oral cavity using ICG-(99m)Tc-nanocolloid.

Authors:  Nynke S van den Berg; Oscar R Brouwer; W Martin C Klop; Bariş Karakullukcu; Charlotte L Zuur; I Bing Tan; Alfons J M Balm; Michiel W M van den Brekel; Renato A Valdés Olmos; Fijs W B van Leeuwen
Journal:  Eur J Nucl Med Mol Imaging       Date:  2012-04-18       Impact factor: 9.236

8.  99mTc-labeled superparamagnetic iron oxide nanoparticles for multimodality SPECT/MRI of sentinel lymph nodes.

Authors:  Renata Madru; Pontus Kjellman; Fredrik Olsson; Karin Wingårdh; Christian Ingvar; Freddy Ståhlberg; Johan Olsrud; Jimmy Lätt; Sarah Fredriksson; Linda Knutsson; Sven-Erik Strand
Journal:  J Nucl Med       Date:  2012-02-09       Impact factor: 10.057

9.  Novel handheld magnetometer probe based on magnetic tunnelling junction sensors for intraoperative sentinel lymph node identification.

Authors:  A Cousins; G L Balalis; S K Thompson; D Forero Morales; A Mohtar; A B Wedding; B Thierry
Journal:  Sci Rep       Date:  2015-06-03       Impact factor: 4.379

10.  A novel method for intraoperative sentinel lymph node detection in prostate cancer patients using superparamagnetic iron oxide nanoparticles and a handheld magnetometer: the initial clinical experience.

Authors:  Alexander Winter; Joachim Woenkhaus; Friedhelm Wawroschek
Journal:  Ann Surg Oncol       Date:  2014-09-05       Impact factor: 5.344

View more
  1 in total

1.  Raman Nanotags-Guided Intraoperative Sentinel Lymph Nodes Precise Location with Minimal Invasion.

Authors:  Binge Deng; Yaohui Wang; Yifan Wu; Wenjin Yin; Jinsong Lu; Jian Ye
Journal:  Adv Sci (Weinh)       Date:  2021-11-05       Impact factor: 16.806

  1 in total