Literature DB >> 29843225

Acoustic radiation force impulse elastography in evaluation of triple-negative breast cancer: A preliminary experience.

Jing Wan1,2, Rong Wu1,2, Minghua Yao1,2, Guang Xu1,2, Hui Liu1,2, Huan Pu1,2, Lihua Xiang1,2, Shupin Zhang1,2,3.   

Abstract

PURPOSE: To assess the elastographic features of triple-negative breast cancers and evaluate the diagnostic value of acoustic radiation force impulse imaging (ARFI) for the characterization of triple-negative breast cancers.
MATERIALS AND METHODS: This study analyzed data from 234 women with breast cancer. Patients were categorized into three groups; 1) triple-negative breast cancers (n = 48); 2) ER-positive tumors (n = 128) and 3) HER2-positive tumors (n = 58). Mean tumor stiffness was evaluated by virtual touch tissue imaging (VTI) and virtual touch tissue quantification (VTQ) and quantified as both qualitative scores (1-5) and shear wave velocity (SWV) (m/s). The relationship between mean SWV and tumor parameters, including tumor size, tumor type, histologic grade and lymph node status, were investigated using multiple linear regression.
RESULTS: Triple-negative tumor were more likely to have a large invasive size (p = 0.002), high histological grade (p < 0.001), lymph node involvement (p = 0.022) and strong ki-67 expression (p < 0.001). The highest mean SWV value were recorded in triple-negative tumors (7.36 m/s±1.83), followed by HER2+ tumors (6.65 m/s±2.26) and ER+ tumors (6.60 m/s±2.35) (p = 0.122). Triple-negative tumors were also associated with increased stiffness than ER+ tumors and HER2+ tumors (p = 0.016), as measured by qualitative VTI scores. Tumor size was independently associated with mean SWV value on adjusted regression (p < 0.001).
CONCLUSIONS: Triple-negative breast cancer is associated with high stiffness scores and SWV in ARFI. The latter may be considered a useful complementary tool in evaluation of triple-negative breast cancer.

Entities:  

Keywords:  Ultrasound; elastography; triple-negative breast cancer; virtual touch tissue imaging; virtual touch tissue quantification

Mesh:

Year:  2018        PMID: 29843225     DOI: 10.3233/CH-170363

Source DB:  PubMed          Journal:  Clin Hemorheol Microcirc        ISSN: 1386-0291            Impact factor:   2.375


  2 in total

1.  Calcification, Posterior Acoustic, and Blood Flow: Ultrasonic Characteristics of Triple-Negative Breast Cancer.

Authors:  Kangjian Wang; Zongkai Zou; Haolin Shen; Guimei Huang; Shuping Yang
Journal:  J Healthc Eng       Date:  2022-09-26       Impact factor: 3.822

2.  Changes in Muscle Stiffness in Infants with Congenital Muscular Torticollis.

Authors:  Dongmin Hwang; Young Ju Shin; Ja Young Choi; Soo Jin Jung; Shin-Seung Yang
Journal:  Diagnostics (Basel)       Date:  2019-10-23
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.