Literature DB >> 29843078

Quantifying the uncertainty in model parameters using Gaussian process-based Markov chain Monte Carlo in cardiac electrophysiology.

Jwala Dhamala1, Hermenegild J Arevalo2, John Sapp3, B Milan Horácek3, Katherine C Wu2, Natalia A Trayanova2, Linwei Wang4.   

Abstract

Model personalization requires the estimation of patient-specific tissue properties in the form of model parameters from indirect and sparse measurement data. Moreover, a low-dimensional representation of the parameter space is needed, which often has a limited ability to reveal the underlying tissue heterogeneity. As a result, significant uncertainty can be associated with the estimated values of the model parameters which, if left unquantified, will lead to unknown variability in model outputs that will hinder their reliable clinical adoption. Probabilistic estimation of model parameters, however, remains an unresolved challenge. Direct Markov Chain Monte Carlo (MCMC) sampling of the posterior distribution function (pdf) of the parameters is infeasible because it involves repeated evaluations of the computationally expensive simulation model. To accelerate this inference, one popular approach is to construct a computationally efficient surrogate and sample from this approximation. However, by sampling from an approximation, efficiency is gained at the expense of sampling accuracy. In this paper, we address this issue by integrating surrogate modeling of the posterior pdf into accelerating the Metropolis-Hastings (MH) sampling of the exact posterior pdf. It is achieved by two main components: (1) construction of a Gaussian process (GP) surrogate of the exact posterior pdf by actively selecting training points that allow for a good global approximation accuracy with a focus on the regions of high posterior probability; and (2) use of the GP surrogate to improve the proposal distribution in MH sampling, in order to improve the acceptance rate. The presented framework is evaluated in its estimation of the local tissue excitability of a cardiac electrophysiological model in both synthetic data experiments and real data experiments. In addition, the obtained posterior distributions of model parameters are interpreted in relation to the factors contributing to parameter uncertainty, including different low-dimensional representations of the parameter space, parameter non-identifiability, and parameter correlations.
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Cardiac electrophysiology; Gaussian process; Markov chain Monte Carlo; Probabilistic local parameter estimation; Uncertainty quantification

Mesh:

Year:  2018        PMID: 29843078      PMCID: PMC6076346          DOI: 10.1016/j.media.2018.05.007

Source DB:  PubMed          Journal:  Med Image Anal        ISSN: 1361-8415            Impact factor:   8.545


  23 in total

Review 1.  Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart. A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association.

Authors:  Manuel D Cerqueira; Neil J Weissman; Vasken Dilsizian; Alice K Jacobs; Sanjiv Kaul; Warren K Laskey; Dudley J Pennell; John A Rumberger; Thomas Ryan; Mario S Verani
Journal:  Circulation       Date:  2002-01-29       Impact factor: 29.690

Review 2.  Models of cardiac tissue electrophysiology: progress, challenges and open questions.

Authors:  R H Clayton; O Bernus; E M Cherry; H Dierckx; F H Fenton; L Mirabella; A V Panfilov; F B Sachse; G Seemann; H Zhang
Journal:  Prog Biophys Mol Biol       Date:  2010-05-27       Impact factor: 3.667

3.  Application of stochastic finite element methods to study the sensitivity of ECG forward modeling to organ conductivity.

Authors:  Sarah E Geneser; Robert M Kirby; Robert S MacLeod
Journal:  IEEE Trans Biomed Eng       Date:  2008-01       Impact factor: 4.538

4.  MRI Based Bayesian Personalization of a Tumor Growth Model.

Authors:  Matthieu Le; Herve Delingette; Jayashree Kalpathy-Cramer; Elizabeth R Gerstner; Tracy Batchelor; Jan Unkelbach; Nicholas Ayache
Journal:  IEEE Trans Med Imaging       Date:  2016-04-29       Impact factor: 10.048

5.  Personalization of a cardiac electrophysiology model using optical mapping and MRI for prediction of changes with pacing.

Authors:  Jatin Relan; Mihaela Pop; Hervé Delingette; Graham A Wright; Nicholas Ayache; Maxime Sermesant
Journal:  IEEE Trans Biomed Eng       Date:  2011-01-20       Impact factor: 4.538

6.  Feasibility of using patient-specific models and the "minimum cut" algorithm to predict optimal ablation targets for left atrial flutter.

Authors:  Sohail Zahid; Kaitlyn N Whyte; Erica L Schwarz; Robert C Blake; Patrick M Boyle; Jonathan Chrispin; Adityo Prakosa; Esra G Ipek; Farhad Pashakhanloo; Henry R Halperin; Hugh Calkins; Ronald D Berger; Saman Nazarian; Natalia A Trayanova
Journal:  Heart Rhythm       Date:  2016-04-19       Impact factor: 6.343

7.  Velocity-based cardiac contractility personalization from images using derivative-free optimization.

Authors:  Ken C L Wong; Maxime Sermesant; Kawal Rhode; Matthew Ginks; C Aldo Rinaldi; Reza Razavi; Hervé Delingette; Nicholas Ayache
Journal:  J Mech Behav Biomed Mater       Date:  2014-12-13

8.  A collocation--Galerkin finite element model of cardiac action potential propagation.

Authors:  J M Rogers; A D McCulloch
Journal:  IEEE Trans Biomed Eng       Date:  1994-08       Impact factor: 4.538

9.  Coupled personalization of cardiac electrophysiology models for prediction of ischaemic ventricular tachycardia.

Authors:  Jatin Relan; Phani Chinchapatnam; Maxime Sermesant; Kawal Rhode; Matt Ginks; Hervé Delingette; C Aldo Rinaldi; Reza Razavi; Nicholas Ayache
Journal:  Interface Focus       Date:  2011-03-30       Impact factor: 3.906

10.  Physiological-model-constrained noninvasive reconstruction of volumetric myocardial transmembrane potentials.

Authors:  Linwei Wang; Heye Zhang; Ken C L Wong; Huafeng Liu; Pengcheng Shi
Journal:  IEEE Trans Biomed Eng       Date:  2009-06-16       Impact factor: 4.538

View more
  10 in total

1.  ML and MAP estimation of parameters for the Kalman filter and smoother applied to electrocardiographic imaging.

Authors:  Taha Erenler; Yesim Serinagaoglu Dogrusoz
Journal:  Med Biol Eng Comput       Date:  2019-07-30       Impact factor: 2.602

Review 2.  An audit of uncertainty in multi-scale cardiac electrophysiology models.

Authors:  Richard H Clayton; Yasser Aboelkassem; Chris D Cantwell; Cesare Corrado; Tammo Delhaas; Wouter Huberts; Chon Lok Lei; Haibo Ni; Alexander V Panfilov; Caroline Roney; Rodrigo Weber Dos Santos
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2020-05-25       Impact factor: 4.226

Review 3.  How personalized heart modeling can help treatment of lethal arrhythmias: A focus on ventricular tachycardia ablation strategies in post-infarction patients.

Authors:  Natalia A Trayanova; Ashish N Doshi; Adityo Prakosa
Journal:  Wiley Interdiscip Rev Syst Biol Med       Date:  2020-01-09

4.  Impact of the Endocardium in a Parameter Optimization to Solve the Inverse Problem of Electrocardiography.

Authors:  Gwladys Ravon; Yves Coudière; Mark Potse; Rémi Dubois
Journal:  Front Physiol       Date:  2019-01-22       Impact factor: 4.566

5.  Creation and application of virtual patient cohorts of heart models.

Authors:  S A Niederer; Y Aboelkassem; C D Cantwell; C Corrado; S Coveney; E M Cherry; T Delhaas; F H Fenton; A V Panfilov; P Pathmanathan; G Plank; M Riabiz; C H Roney; R W Dos Santos; L Wang
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2020-05-25       Impact factor: 4.226

6.  EP-PINNs: Cardiac Electrophysiology Characterisation Using Physics-Informed Neural Networks.

Authors:  Clara Herrero Martin; Alon Oved; Rasheda A Chowdhury; Elisabeth Ullmann; Nicholas S Peters; Anil A Bharath; Marta Varela
Journal:  Front Cardiovasc Med       Date:  2022-02-03

7.  Fast Posterior Estimation of Cardiac Electrophysiological Model Parameters via Bayesian Active Learning.

Authors:  Md Shakil Zaman; Jwala Dhamala; Pradeep Bajracharya; John L Sapp; B Milan Horácek; Katherine C Wu; Natalia A Trayanova; Linwei Wang
Journal:  Front Physiol       Date:  2021-10-25       Impact factor: 4.566

8.  Pacemaking function of two simplified cell models.

Authors:  Maxim Ryzhii; Elena Ryzhii
Journal:  PLoS One       Date:  2022-04-11       Impact factor: 3.240

Review 9.  Computational models in cardiology.

Authors:  Steven A Niederer; Joost Lumens; Natalia A Trayanova
Journal:  Nat Rev Cardiol       Date:  2019-02       Impact factor: 32.419

10.  Effects of Anti-Diabetic Drugs on Fracture Risk: A Systematic Review and Network Meta-Analysis.

Authors:  Yu-Sheng Zhang; Yan-Dan Zheng; Yan Yuan; Shi-Chun Chen; Bao-Cheng Xie
Journal:  Front Endocrinol (Lausanne)       Date:  2021-10-14       Impact factor: 5.555

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.