Literature DB >> 29807953

Evaluation of a multiplex flow immunoassay versus conventional assays in detecting autoantibodies in systemic lupus erythematosus.

E Y Au1, W K Ip1, C S Lau2, Y T Chan1.   

Abstract

INTRODUCTION: Conventional diagnostic assays are being replaced with automated multiplex assays, but their performance needs to be evaluated. We compared a multiplex flow immunoassay with conventional techniques in the detection of antinuclear antibodies (ANAs) and antibodies to specific extractable nuclear antigens (ENAs) in serum samples from patients with systemic lupus erythematosus.
METHODS: A total of 140 consecutive Chinese patients with systemic lupus erythematosus and 41 healthy controls were included. The automated BioPlex 2200 ANA Screen assay (Bio-Rad Laboratories, Hercules [CA], US) was compared with indirect immunofluorescence. In addition, use of BioPlex 2200 to detect anti-ENA antibodies was compared with in-house assays of countercurrent immunoelectrophoresis (CIEP), enzyme-linked immunosorbent assay (ELISA), and line blot.
RESULTS: The sensitivity and specificity of BioPlex in detecting ANAs (91.4% and 95.1%, respectively) were comparable to those of indirect immunofluorescence (90.7% and 85.4%, respectively). Overall, BioPlex achieved the best agreement with ELISA in detecting anti-ENA antibodies: agreement was >90% for most antibody types (κ=0.79-0.94). In contrast, agreement was poorest with CIEP, ranging from 85.6% (κ=0.33) for anti-Sm antibodies to 93.9% (κ=0.88) for anti-Ro antibodies. Overall, BioPlex and ELISA had the highest sensitivity, whereas CIEP had the highest specificity. In terms of disease association, anti-Sm detected by CIEP had the best positive predictive value and specificity for lupus nephritis.
CONCLUSIONS: In a local lupus cohort, BioPlex showed comparable sensitivity to indirect immunofluorescence in detecting ANAs and comparable performance to ELISA in detecting anti-ENA antibodies. However, CIEP was the best method in terms of disease specificity.

Entities:  

Keywords:  Antibodies; Enzyme-linked immunosorbent assay; Methods

Mesh:

Substances:

Year:  2018        PMID: 29807953     DOI: 10.12809/hkmj177007

Source DB:  PubMed          Journal:  Hong Kong Med J        ISSN: 1024-2708            Impact factor:   2.227


  2 in total

1.  Prevalence of autoantibody responses in acute coronavirus disease 2019 (COVID-19).

Authors:  L Angelica Lerma; Anu Chaudhary; Andrew Bryan; Chihiro Morishima; Mark H Wener; Susan L Fink
Journal:  J Transl Autoimmun       Date:  2020-11-27

2.  Detection of Anti-Extractable Nuclear Antigens in Patients with Systemic Rheumatic Disease via Fluorescence Enzyme Immunoassay and Its Clinical Utility.

Authors:  Joowon Oh; Younhee Park; Kyung A Lee; Hyon Suk Kim
Journal:  Yonsei Med J       Date:  2020-01       Impact factor: 2.759

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.