AIMS: Left atrial appendage occlusion (LAAO) is a stroke prevention therapy for patients with non-valvular atrial fibrillation (AF). This study reports one-year outcomes from patients enrolled in the prospective global Amulet registry. METHODS AND RESULTS: A total of 1,088 patients were recruited, aged 75±9 years; 65% of patients were male. The CHA2DS2-VASc and HAS-BLED scores were 4.2±1.6 and 3.3±1.1, respectively. Eighty-three percent (83%) of patients had contraindications to anticoagulation (OAC); 72% had a history of major bleeding. An AMPLATZER Amulet LAA occluder was successfully implanted in 99% of cases. Transoesophageal echocardiography one to three months after implant showed no residual flow or flow <3 mm in 98.4%. The observed ischaemic stroke rate was 2.9%/year. Device-related thrombus was noted in 1.7% of patients. There were ten cases between 0 and 90 days and eight cases between 91 and 365 days. Patients discharged without OAC (>80%), in particular those on single aspirin therapy, did not appear to have a higher risk of device-related thrombus. In the first year, major bleeding occurred at an annualised rate of 10.3%. All-cause mortality was 8.4% at one year. CONCLUSIONS: In the global prospective Amulet registry of patients at high risk of stroke and bleeding, the annualised ischaemic stroke rate was 2.9%. The LAA was sealed in 98.4% after one to three months and device-related thrombus was observed in 1.7% of cases with only a minority of all patients on anticoagulation treatment.
AIMS: Left atrial appendage occlusion (LAAO) is a stroke prevention therapy for patients with non-valvular atrial fibrillation (AF). This study reports one-year outcomes from patients enrolled in the prospective global Amulet registry. METHODS AND RESULTS: A total of 1,088 patients were recruited, aged 75±9 years; 65% of patients were male. The CHA2DS2-VASc and HAS-BLED scores were 4.2±1.6 and 3.3±1.1, respectively. Eighty-three percent (83%) of patients had contraindications to anticoagulation (OAC); 72% had a history of major bleeding. An AMPLATZER Amulet LAA occluder was successfully implanted in 99% of cases. Transoesophageal echocardiography one to three months after implant showed no residual flow or flow <3 mm in 98.4%. The observed ischaemic stroke rate was 2.9%/year. Device-related thrombus was noted in 1.7% of patients. There were ten cases between 0 and 90 days and eight cases between 91 and 365 days. Patients discharged without OAC (>80%), in particular those on single aspirin therapy, did not appear to have a higher risk of device-related thrombus. In the first year, major bleeding occurred at an annualised rate of 10.3%. All-cause mortality was 8.4% at one year. CONCLUSIONS: In the global prospective Amulet registry of patients at high risk of stroke and bleeding, the annualised ischaemic stroke rate was 2.9%. The LAA was sealed in 98.4% after one to three months and device-related thrombus was observed in 1.7% of cases with only a minority of all patients on anticoagulation treatment.
Authors: Tatiana Busu; Safi U Khan; Muhammad Alhajji; Fahad Alqahtani; David R Holmes; Mohamad Alkhouli Journal: Am J Cardiol Date: 2020-03-14 Impact factor: 2.778
Authors: Mohammed Osman; Tatiana Busu; Khansa Osman; Safi U Khan; Matthew Daniels; David R Holmes; Mohamad Alkhouli Journal: JACC Clin Electrophysiol Date: 2020-01-29
Authors: Matthew J Price; David Slotwiner; Chengan Du; James V Freeman; Zoltan Turi; Chidambaram Rammohan; Fred M Kusumoto; Clifford Kavinsky; Joseph Akar; Paul D Varosy; Christina Koutras; Jeptha P Curtis; Frederick A Masoudi Journal: JACC Cardiovasc Interv Date: 2022-04-11 Impact factor: 11.075
Authors: Michael Gotzmann; Dinah S Choudhury; Maximilian Hogeweg; Florian Heringhaus; Andreas Mügge; Andreas Pflaumbaum Journal: Clin Cardiol Date: 2020-01-22 Impact factor: 2.882