Literature DB >> 29806783

Evaluation of the ultrasound effect on treated municipal wastewater.

Monserrat Vázquez-López1, Leonel Ernesto Amabilis-Sosa2, Gabriela Eleonora Moeller-Chávez1, Adriana Roé-Sosa3, Patricio Neumann4,5, Gladys Vidal5.   

Abstract

In this research, ultrasound (US; 26 kHz) application was evaluated as tertiary treatment of treated municipal wastewater coming from conventional activated sludge (AS) and constructed wetland (CW) systems. The degree of disinfection was evaluated through the total (TC) and faecal (FC) coliforms and by somatic coliphages (SCs) determinations. The experiments were carried out without temperature control at times of 200, 400 and 600 s and with temperature control (298.1 K) at 600, 1200 and 1800 s. Changes in the concentrations of C, N and P were also studied. The results shown that treatment without temperature control allowed 100% inactivation for TC, FC and SC at 600 s, while maximum with temperature was achieved at 1800 s. Temperature was an important factor influencing pathogens inactivation. In both cases, microorganism concentrations complied with different international guidelines for the reuse of treated wastewater. At 1800 s sonication concentrations of biochemical oxygen demand, chemical oxygen demand and total phosphorus were reduced 39.5, 39.4, 50.0 and 37.3% TN in the AS-treated water and 24.0, 49.8, 20.2 and 7.7% in the CW-treated water, respectively. In both cases, the formation of H⋅ and OH⋅ radicals is most likely related to the observed pollutants removal. While energy consumption of ultrasound was higher than other advanced treatments such as electrocoagulation, its implementation allows the simultaneous removal of pathogens and organic pollutants without the generation of toxic by-products. In conclusion, ultrasound can be implemented as tertiary treatment of municipal wastewater for the removal of biological and organic pollution, according to reuse guidelines in terms of pathogens presence.

Entities:  

Keywords:  Ultrasound; coliforms and coliphages; wastewater and water stress

Mesh:

Substances:

Year:  2018        PMID: 29806783     DOI: 10.1080/09593330.2018.1481889

Source DB:  PubMed          Journal:  Environ Technol        ISSN: 0959-3330            Impact factor:   3.247


  1 in total

1.  Tertiary treatment (Chlorella sp.) of a mixed effluent from two secondary treatments (immobilized recombinant P. pastori and rPOXA 1B concentrate) of coloured laboratory wastewater (CLWW).

Authors:  Leidy D Ardila-Leal; Valentina Hernández-Rojas; Diana N Céspedes-Bernal; Juan F Mateus-Maldonado; Claudia M Rivera-Hoyos; Lucas D Pedroza-Camacho; Raúl A Poutou-Piñales; Aura M Pedroza-Rodríguez; Alejandro Pérez-Florez; Balkys E Quevedo-Hidalgo
Journal:  3 Biotech       Date:  2020-05-06       Impact factor: 2.406

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.